Sale!

PXI-7852 National Instruments

¥666.00

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

PXI-7852 National Instruments
PXI-7852 National Instruments
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com

I cannot see my third-party USB instrument in Measurement&Automation Explorer (MAX), but it exists as a USB instrument in Windows Device Manager. Why do we see this phenomenon and how can we solve it so that we can communicate with the instrument?
My USB-6343 performs normally in Windows Device Manager, but in MAX, there is a yellow triangle and a message is displayed: There was a problem updating the settings for this device. The operation timed out.
I cannot see my 3rd Party USB devices in MAX, but I can communicate with them through the command line, so I know they are connected. What do I need to do to see my device in MAX?
Solution
If the device is displayed in the Windows Device Manager, it indicates that the Windows machine can recognize the USB device and has associated a specific driver to communicate with the device. One possible reason why the instrument did not display in MAX is that Windows did not associate the correct driver with the device.
Check if the NI-VISA driver is installed on the computer. If doing so, please check the compatibility between NI-VISA and LabVIEW, as well as the compatibility between NI-VISA and the operating system. If not, please visit the NI-VISA download page and download and install the appropriate driver. Please ensure to restart the computer after installation.
Try resetting the MAX database, as described in the article on how to repair or reset the NI MAX database file.
If you are using a third-party VISA device on the same computer, you may need to set NI-VISA as the primary VISA implementation, as described in the NI VISA article after installing third-party VISA software.
Uninstall and reinstall the NI-VISA driver. When reinstalling, if possible, disable all firewalls and antivirus software.
If NI-VISA is installed, please try re associating the USB device to use the NI-VISA driver:
Go to Windows Device Manager and search for USB devices according to the following image.
Use NI”s counting/timer or M-series board to complete resettable pulse counting PXI-7852 National Instruments
Main software:
Main software version: 1.0
Main software revision version: N/A
Secondary software: LabVIEW Development Systems>>LabVIEW Base Package
Hardware: Counter/Timers (TIO)>>Devices>>PCI-6601
Question: I want to use NI”s counting/timer or M-series board to perform edge counting on my input signal and reset the count with another pulse signal.
Answer: If an external trigger source is used, such requirements can be completed using any of NI”s M-series cards with a counter or counting/timer. The counting/counter board is particularly suitable for generating counting reset signals, as other counters on the board can be used to generate a pulse signal of a known frequency.
There are two ways to use the counter input. The first method is a two channel pulse encoding method with Z index. This method uses two input signals, channel A and channel B, to count, while the Z-channel signal is used to reset the count. This method uses the rising edge of channel A to increase the count, while the rising edge of channel B to decrease the count. Therefore, the two pulse encoding method is also called an add/subtract counter.
Set the signal values in channels A and B to determine when the Z-channel signal triggers a count reset. This allows you to perform an accurate count reset without causing loss of counts for channels A and B. Count reset can be completed within one clock cycle of the maximum time base.
For a specific example, if we only need to increase the count, we can ground channel B. The relevant connection relationships for this setting are as follows:
Ctr Source: Incremental count signal (channel A)
Ctr AUX: Decrement count signal (channel B) – connected to ground
Ctr Gate: Reset signal (Z-path index)
The following figure describes the Counting process of resetting the count when the channel A and channel B signals are both low.
Regarding the Z-path index, both page 39 of the 6601/6602 User Manual and page 120 of the M Series User Manual need to be introduced.
The following attachment is a simple VI example using Z-path indexing.
The second measurement method is buffer period measurement. The relevant content is detailed on the NI Developer Zone website.

 

PCI-6033E
PCI-6032E
PCI-6031E
PCI-6030E
PCI-6025E
PCI-6024E
PCI-6023E
PCI-6011E
PCI-5922
PCI-5911
PCI-5640R
PCI-5640
PCI-5154
PCI-5153EX
PCI-5153
PCI-5152
PCI-5142
PCI-5124
PCI-5122EX
PCI-5122
PCI-5114
PCI-5112
PCI-5105
PCI-5102
PCI-4552
PCI-4551
PCI-4474
PCI-4472B
PCI-4472
PCI-4462
PCI-4461
PCI-4454
PCI-4452
PCI-4451
PCI-4070
PCI-4021
NI-9917
NI-9683
NI-9505
NI-9260 NI
ni-9250
NI-9234
Ni-9227
NI-9208
NI-9159
NI-9157
NI-9155
NI-9154
NI-9151
NI-9149
NI-9148
NI-9147
NI-9146
NI-9145
NI-9144
NI-5741
NI-5191
PXIE-2529
PXI-2520
USB-6525
PXIE-8840QC
PXIE-8840
PXIE-8135
PXIE-4081
pxie-4080
PXI-8461
PXI-6713
PXI-6683
PXI-6602
PXI-5402
PXI-2564
PXI-2510
PCIE-6321
NI-9216
GPIB-140A/2
FP-TB-1
CFP-DO-403
CFP-DO-400
CFP-DI-304
CFP-CB-1
CFP-AO-210
CFP-AO-200
CFP-AI-111
CFP-AI-100
CFP-1808
CFP-1804
AT-5102

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts