Sale!

3706A TRICONEX controller

¥666.00

3706A TRICONEX controller
Brand: TRICONEX
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

3706A TRICONEX controller
3706A TRICONEX controller
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com
How to Build High Channel Density Digital IO Modules for the Next Generation Industrial Automation Controllers
With the rapid development of industrial automation, digital IO modules have become an indispensable part of industrial automation controllers. The digital IO module can connect the controller with external devices, such as sensors, actuators, etc., to achieve monitoring and control of industrial production processes. However, with the continuous development of industrial automation, digital IO modules need to have higher channel density and stronger functionality to meet the needs of new industrial automation controllers. Therefore, it is very important to build high channel density digital IO modules for the next generation of industrial automation controllers.
The digital IO module is one of the most fundamental modules in industrial automation controllers, and its main function is to connect the controller with external devices to achieve signal input and output. The digital IO module usually includes two parts: a digital input module and a digital output module. The digital input module can convert the digital signals of external devices into signals that the controller can read, while the digital output module can convert the digital signals output by the controller into signals that external devices can read. The channel density of a digital IO module refers to the number of digital input or digital output channels provided on the module, which is the input and output capacity of the module.
With the development of industrial automation, digital IO modules need to have higher channel density and stronger functions to meet the needs of new industrial automation controllers. The following are several aspects to consider when building a high channel density digital IO module for the next generation of industrial automation controllers:3706A TRICONEX controller
1. Choose the appropriate communication protocol
Digital IO modules typically communicate with controllers through communication protocols, so choosing a suitable communication protocol is crucial. Common communication protocols include Modbus, Profibus, CANopen, Ethernet, etc. Different communication protocols have different advantages and disadvantages, and selecting a suitable communication protocol requires considering the following factors:
(1) Communication speed: The faster the communication speed, the shorter the response time of the digital IO module, which can process input and output signals faster.
(2) Communication distance: The farther the communication distance, the wider the application range of digital IO modules.
(3) Reliability: The reliability of communication protocols determines the stability and reliability of digital IO modules.
(4) Cost: Different communication protocols have different costs, and suitable communication protocols need to be selected based on actual needs.
2. Choose the appropriate digital IO chip
The digital IO chip is the core component of the digital IO module, and its performance and function directly affect the channel density and function of the digital IO module. Choosing a suitable digital IO chip requires considering the following factors:
(1) Channel density: The channel density of digital IO chips determines the channel density of digital IO modules, and channel density needs to be selected based on actual needs.
(2) Input/output type: Digital IO chips usually support digital input and digital output, and some chips also support functions such as analog input and output, counters, etc.
(3) Speed: The speed of the digital IO chip determines the response speed of the digital IO module, and it is necessary to choose a chip with a faster speed.
(4) Accuracy: The accuracy of digital IO chips determines the signal accuracy of digital IO modules, and it is necessary to choose chips with higher accuracy.
(5) Cost: Different digital IO chips have different costs, and suitable chips need to be selected based on actual needs.
3. Optimize circuit design
The circuit design of digital IO modules has a significant impact on their performance and stability. In order to improve the channel density and functionality of digital IO modules, it is necessary to optimize circuit design, such as:
(1) Using high-speed digital IO chips: Using high-speed digital IO chips can improve the response speed and accuracy of the module.
(2) Adopting anti-interference design: In order to improve the stability of the digital IO module, it is necessary to adopt anti-interference design, such as using filters, isolators, etc.
(3) Using optimized PCB layout: Optimizing PCB layout can reduce noise and interference in digital IO modules, improve module performance and stability.
4. Choose the appropriate shell material and size
Digital IO modules typically need to be installed in cabinets or control cabinets, so choosing the appropriate housing material and size is crucial. The shell material should have good protective and heat dissipation properties to protect the circuits of the digital IO module from external environmental influences. The shell size should be able to adapt to different installation environments, such as cabinets, control cabinets, etc.
5. Optimize software design
The software design of the digital IO module determines its functionality and performance. In order to achieve high channel density and stronger functionality, it is necessary to optimize software design, such as:
(1) Supporting multiple input and output types: Supporting multiple input and output types can meet different application needs, such as digital input and output, analog input and output, counters, etc.
(2) Supporting multiple communication protocols: Supporting multiple communication protocols can adapt to different controllers and application environments.
(3) Support for online debugging and monitoring: Supporting online debugging and monitoring can facilitate user diagnosis and maintenance of modules.
(4) Support for expansion function: Supporting expansion function can increase the functionality and application range of the module while ensuring channel density.
In summary, building a high channel density digital IO module for the next generation of industrial automation controllers requires multiple considerations, including selecting suitable communication protocols, selecting suitable digital IO chips, optimizing circuit design, selecting suitable shell materials and sizes, and optimizing software design. Only by comprehensively considering these factors can a digital IO module with high channel density and stronger functionality be constructed to meet the needs of new industrial automation controllers.
How to assign IO devices to IO controllers?
PROFINET IO system
The PROFINET IO system consists of a PROFINET IO controller and its assigned PROFINET IO devices. After adding IO controllers and IO devices, it is necessary to assign IO controllers to the IO devices to form a basic PROFINET IO system.
Prerequisite requirements
● Already in the network view of STEP 7.
A CPU has been placed (e.g. CPU 1516-3 PN/DP).
● An IO device has been placed (e.g. IM 155-6 PN ST)
Operating Steps (Method 1)
To assign IO devices to IO controllers, follow these steps:
1. Move the mouse pointer over the interface of the IO device.
2. Hold down the left mouse button.
3. Drag the mouse pointer.
The pointer will now use the networking symbol to indicate the “networking” mode. At the same time, you can see a lock character appearing on the pointer
Number. The lock symbol only disappears when the pointer moves to a valid target position.
4. Now, move the pointer to the interface of the desired IO controller and release the left mouse button.
5. Now assign the IO device to the IO controller.
Operating Steps (Method 2)
To assign IO devices to IO controllers, follow these steps:
1. Move the mouse pointer over the word “Unassigned” in the bottom left corner of the IO device icon.
2. Click the left mouse button.
3. Select the IO controller interface to be connected from the available interfaces that appear.
4. Now assign the IO device to the IO controller.
Ethernet IO module assists industrial robots
Industrial robots are multi joint robotic arms or multi degree of freedom machine devices aimed at the industrial field, which can achieve many material distribution, retrieval, pallets, and so on in industrial sites. However, due to the fact that many industrial six axes are equipped with 32 IO ports as standard, the IO ports are not sufficient in practical applications. Therefore, some DIN and DO extensions can be met through IO modules.
MQTT Ethernet IO Remote Module3706A TRICONEX controller
The Modbus TCP Ethernet IO module has multiple channels, such as 4-way, 8-way, and 16-way switch input and output options. The communication protocol of the Ethernet IO module adopts the standard Modbus TCP protocol, Modbus RTU over TCP protocol, and MQTT protocol. Can support LAN configuration, with 1 DC power output to other devices on site, reducing the difficulty and cost of on-site wiring.
Most of the MQTT Ethernet IO modules should collect some IO port information and transmit data through the network port. In fact, the Ethernet IO module can not only serve as a TCP server, but also as a TCP client. In addition, it can not only count high-speed pulses but also output high-3706A TRICONEX controllerspeed pulses. This is very convenient for doing some control processing on industrial sites, such as controlling servo motors and other scenarios! The most important thing is the data caching function. Even if the network is disconnected, it is not afraid. The data will be automatically cached, and after the network is restored, it will be automatically retransmitted.
The MxxxT industrial remote Ethernet I/O data acquisition module is embedded with a 32-bit high-performance microprocessor MCU, and integrates an industrial grade 10/100M adaptive Ethernet interface to support the standard Modbus protocol. It can easily integrate with third-party SCADA software, PLC, and HMI devices for application. Equipped with an RS485 interface, it has good scalability and can be cascaded with standard Modbus RTU I/O devices through the RS485 bus to achieve the combination of various digital, analog, and thermal resistance IO modules, saving costs. At the same time, this device has the function of cluster register mapping, and the data of the cluster is automatically collected into the mapping storage area of the local computer. The upper computer can respond quickly without waiting when querying, meeting the strict and timely functional requirements of industrial sites.
What is a remote IO module and what are its purposes
Technology is constantly evolving, and we can come into contact with various electronic devices both in daily life and in the workplace. And a large number of electronic devices work together to generate some signal sources. In order to better transmit and collect signals, industrial control products such as remote IO modules, signal transmitters, and signal acquisition modules have been developed.
In the past, people had to connect existing lines and boxes one at a time, which greatly increased the cost and construction time of cables. Moreover, if the distance was too long, they also had to face issues such as voltage attenuation. And through the remote IO module, this problem can be effectively solved.
If your cabinet is 200 meters away from the site and remote IO is not used, then you can extend each signal line by 200 meters and install the remote IO module on site, which can save you a lot of cable costs and reduce the complexity of construction.
In short, sometimes some IOs are set far away from the central control room and then connected back to the central control room through fiber optics to save on cable procurement and construction. Sometimes, the logical “remote” is because the allowed quantity of “local IO” cannot meet the actual needs, so it is necessary to connect to the “remote IO template”, which depends on the situation.
In addition, the general cabinet is placed on the equipment site. However, some control signals, such as emergency stop and bypass, are implemented in the control room, so remote IO modules need to be used to transmit these signals to the control system in the computer room.
What is an Ethernet IO module and what are its functions
The Ethernet IO module is a hardware gateway that adds IO to the network port.
The Ethernet IO module has hardware interfaces such as switches, analog signals, relays, RS485, RJ45, etc. Can be used for IO data collection network port transmission in industrial automation. Simply put, it refers to sensors with standard signals on site, or serial devices with 485 signals such as PLCs, which can be converted into real values through such gateways and then transmitted to the host for display through network ports.
1. Collect and control data for internal processing and transmit it to the external network through Ethernet
2. Support 4-way photoelectric isolation switch input
3. Supports 4 independent relay control outputs
4. Supports 8 analog inputs, 4-20mA or 0-5V/0-10V/0-30V (optional)
5. Support RS485 serial port data collection, with serial port server function
6. Supports Modbus RTU communication protocol and virtual serial port
7. Supports docking with various configuration software and TCP/UDP servers
Safety Instrumented System (SIS) is a3706A TRICONEX controller safety system used to monitor and control production processes, and is a system that prevents catastrophic accidents from occurring. SIS is usually composed of sensors, logic solvers, and actuators, which can monitor and control various industrial production processes, including petrochemical, power, metallurgy, pharmaceuticals, pulp, and paper industries. The main function of SIS is to ensure the safety and reliability of industrial processes to prevent accidents from occurring. It can determine whether there are potential hazards or accident risks by monitoring the status of equipment, process parameters, and environmental factors, and take appropriate measures in a timely manner to prevent accidents from occurring. SIS can also be integrated with other control systems such as DCS or PLC to achieve more efficient production process monitoring and management.3706A TRICONEX controller
Invensys is an industrial software and control systems company headquartered in the UK, established in 1987. The company provides a range of solutions, including process automation, factory automation, energy management, railway transportation, aerospace, defense, and automotive fields. Invensys has over 30000 employees worldwide and customers worldwide. In 2019, Invensys was acquired by Schneider Electric of France.
Connex is a provider of industrial automation and information solutions headquartered in the United States, established in 2000. The company mainly provides data collection, monitoring, and visualization solutions, as well as industrial network and communication solutions. Kangjisen has over 2000 employees worldwide and customers worldwide. In China, Kangjisen is fully responsible by Beijing Kangjisen Huagen Technology Co., Ltd., providing sales, technical support, engineering, training, and a series of engineering and technical services.
The MXXE series remote IO module is designed at an industrial level, suitable for industrial IoT and automation control systems. The MXXE industrial Ethernet remote I/O is equipped with two Ethernet ports for MAC layer data exchange chips, allowing data to flow down from the expandable daisy chain Ethernet remote I/O array to another local Ethernet device or up to the server.
Factory automation, security, and monitoring systems, as well as tunnel communication applications, can utilize daisy chain Ethernet to build multi-point I/O networks through standard Ethernet cables. Many industrial automation users are familiar with the most commonly used multipoint configurations in fieldbus solutions. The daisy chain function of MxxXE remote I/O not only improves the scalability and installation possibility of remote I/O applications, but also reduces the overall cost by reducing the need for individual Ethernet switches. This daisy chain equipment installation method will also reduce overall labor and wiring costs.
The difference between Ethernet remote IO module and industrial computer IO board card
The application of Ethernet remote IO module is very extensive, mainly used for distributed data collection and control, especially suitable for situations where data points are scattered and control points are scattered.
The traditional approach is to connect various instrument signals directly to the IO card through cables using an industrial computer and an IO board card. This method has high wiring costs and high signal attenuation.
The Ethernet remote IO module can directly connect the IO module to the PLC or industrial control computer, and connect the IO to the PLC or industrial control computer through an Ethernet cable. Various instrument controller signals can be directly connected to the Ethernet IO module nearby, which has several advantages:
1. It saves industrial control computers and IO boards, and Ethernet IO modules can be directly connected to the upper computer system;
2. Replacing 4-20mA signal transmission with 10/100MHz Ethernet transmission has improved transmission speed;
3. Replacing various instrument controller signal lines with an Ethernet cable reduces the attenuation of remote signal transmission;
4. The signal cable of the instrument controller only needs to be connected to the Ethernet IO module, greatly reducing cable costs and wiring workload;
5. The M160T series Ethernet remote IO module can also be directly transmitted to the Internet of Things platform through MQTT for remote monitoring.
The profinet to Modubs distributed remote IO module has now been applied in many fields, and Huajie Intelligent Control has implemented profinet remote IO modules that support Siemens 200smart, 3001200, and 1500.
Huajie Intelligent Control distributed IO supports Modubs 16D 16DO 32DI 32 DO, with flexible on-site installation, which can be installed nearby with sensors and actuators, saving wiring and PLC”s own IO points. Provides high-speed data transmission, enabling reliable communication between the controller CPU and I/O system
The advantage of using profinet distributed remote IO module in profinet is that the wiring is simple, only one network cable is needed, and each point is collected and controlled through the remote IO module. The program is controlled by Siemens 1200 or 1500, which not only reduces wiring work but also reduces wire costs
Huajie Intelligent Control has good compatibility with distributed IO and has expanded other bus based distributed IO systems, which can also help you more rationalize the management of your distributed remote devices and achieve unlimited expansion. The supporting software can assist with configuration, debugging, and diagnosis of your system. There are multiple series of models available, including HJ3204 to HJ3209, with stable performance and affordable prices, Provide maximum convenience for enterprise engineering.
What exactly does embedded development do?
Embedded development is a technology similar to programming, but our understanding of the scope of programmers is to do computer software, web development, and also to do apps.
The majority of embedded development is intelligent electronic products, which are designed for hardware programming. This hardware can be understood as a circuit board, usually composed of a controller (processor) chip and different circuits.
The specific program and circuit are generally determined by the product function. For example, an electronic clock product is usually composed of a digital tube and a microcontroller (controller), and then written in C language to download it to the microcontroller to achieve clock display.3706A TRICONEX controller
Of course, there are far more products that can be developed in embedded systems, including smartphones, wearable devices, drones, robots, mice and keyboards, and so on.
The knowledge system of embedded development and design is also very diverse, and different products require different learning contents.
So, if we want to enter embedded development, we must first understand several directions of embedded development, otherwise you will never find a starting point.
The general mainstream directions are microcontroller development, ARM+Linux development, and FPGA/DSP development.
I have been working on microcontroller development for the past 10 years of my career.
Microcontrollers can be said to be the foundation of all directions. If you have strong microcontroller development capabilities, then ARM+Linux, or FPGA/DSP are easy for you to get started.
The development of microcontrollers is also one of the directions with the lowest threshold for embedded systems. Initially, I was self-taught in electrical engineering and transferred there. It took me about four months from the beginning of my studies to finding a job.
However, at that time, the threshold was still very low, and you could basically find a job by working on a small project with a 51 microcontroller.
If it”s the current situation, you only know these things and have little competitiveness. Nowadays, the main focus of enterprises is on whether you have project experience, rather than what kind of microcontroller you know.
The project experience can be accumulated through practical projects with endless microcontroller programming, which can be said to be the closest to actual development at present.
At present, the salary of single-chip microcontrollers is not low, and it is normal for them to start at 8K in first tier cities, and they can reach 15K after working for 2-3 years.
There are many industries covered by embedded systems, and in the later stage, based on work, we will only focus on one direction. From a macro perspective, we will divide it into embedded software development and embedded hardware development. Software development is mainly based on application software development on systems (Linux, VxWorks, WinCE, etc.), and hardware development includes motherboard design, system porting, cutting, and writing low-level drivers
My personal experience started with microcontrollers. Firstly, I studied C and C++, digital and analog electronics, power electronics, circuit design, microcontroller principles, FreeRTOS, data structures, and computer operating systems. Later, due to work requirements, I relearned university automation control theory, signals and systems, complex functions, linear algebra, calculus, statistics, and compiler principles. These are all basics, and it is important to understand and thoroughly study them, This will bring help to the later research and development work, and there is also a need for more drawing board, drawing board, and practical operation. Without practicing optics, the efficiency is very low, and knowledge is repetitive. Only by repeatedly looking and using can we understand. We can buy some development boards to assist in learning. Now that the internet is developed, network resources can improve our learning efficiency.
Embedded development refers to developing under an embedded operating system, commonly used systems include WinCE, ucos, vxworks, Linux, Android, etc. In addition, develop using C, C++, or assembly; Using advanced processors such as arm7, arm9, arm11, powerpc, mips, mipsel, or operating systems also belongs to embedded development.
1. Basic knowledge:
Purpose: I can understand the working principles of hardware, but the focus is on embedded software, especially operating system level software, which will be my advantage.
Subjects: Digital Circuits, Principles of Computer Composition, and Embedded Microprocessor Architecture.
Assembly Language, C/C++, Compilation Principles, Discrete Mathematics.
Data structure and algorithms, operating systems, software engineering, networks, databases.
Method: Although there are many subjects, they are all relatively simple foundations and most of them have been mastered. Not all courses may be taught, but elective courses can be taken as needed.
Main books: The C++programming language (I haven”t had time to read it), Data Structure-C2.
2. Learning Linux:
Purpose: To gain a deeper understanding of the Linux system.
Method: Using Linux ->Linxu system programming development ->Driver development and analysis of the Linux kernel. Let”s take a closer look, then the main topic is principles. After reading it a few times, look at the scenario analysis and compare it deeply. The two books intersect, with depth being the outline and emotion being the purpose. Analysis is version 0.11, suitable for learning. Finally, delve into the code.
Main books: Complete Analysis of Linux Kernel, Advanced Programming in Unix Environment, Deep Understanding of Linux Kernel, Scenario Analysis, and Source Generation.
3. Learning embedded Linux:
Purpose: To master embedded processors and their systems.
Method: (1) Embedded microprocessor structure and application: Direct arm principle and assembly are sufficient, without repeating x86.
(2) Embedded operating system class: ucOS/II is simple, open source, and easy to get started. Then delve deeper into uClinux.
(3) Must have a development board (arm9 or above) and have the opportunity to participate in training (fast progress, able to meet some friends).
Main books: Mao Decao”s “Embedded Systems” and other arm9 manuals and arm assembly instructions.
What is the function of an IO chip
Io generally refers to input and output devices, where I is the input and O is the output. The input to the IO port of the chip is the external signal transmission to the chip, while the output is the internal signal transmission to other devices. The input and output are relative. In short, in a broad sense, the control of input and output interfaces is called an IO chip, and network cards are also considered IO or array cards.
The CPU must read and write data to external registers or ROMs on RAM or other hardware through IO commands (such as input/output commands). For example, reading a keyboard involves accessing external registers on the keyboard through the 60H port, and the chip on the keyboard scans the keyboard. Pressing or holding down a key for a long time will cause the chip to generate corresponding scan or break codes, which will be written to the external register of the 60H port, so that the CPU can achieve the purpose of controlling the keyboard. Therefore, I think IO chips should refer to a large category. The CPU already has powerful IO instructions and corresponding control buses.
51 microcontroller IO port input and output mode_ Four usage methods for IO ports
The traditional 51 microcontroller IO interface can only be used as a standard bidirectional IO interface. If it is used to drive LED, it can only be driven by injecting current or using a transistor external expansion drive circuit.
Current injection method: LED positive pole connected to VCC, negative pole connected to IO port. If the IO is at a high level, the two poles of the LED are at the same level, and there is no current, the LED will turn off; IO is at low power level, current flows from VCC to IO, and LED lights up. But when you connect the positive pole of the LED to the IO interface and the negative pole to GND, placing the IO interface at a high level will cause the LED to light up. However, due to the insufficient pull-up capability of the IO interface, the brightness is not ideal. The following method can be used to solve this problem.
Push-pull working mode: The positive and negative poles of the LED are connected to two IO ports, and then the positive IO interface is set as the push-pull output, while the negative IO interface is set as the standard bidirectional current input. The push pull method has strong pull-up ability and can achieve high-level LED driving.
Four usage methods for IO ports3706A TRICONEX controller
From the perspective of the characteristics of the I/O port, the P0 port of Standard 51 is an open drain structure when used as an I/O port, and in practical applications, a pull-up resistor is usually added; P1, P2, and P3 are all quasi bidirectional I/Os with internal pull-up resistors, which can be used as both input and output. The I/O port characteristics of the LPC900 series microcontroller have certain differences, and they can be configured into four different working modes: quasi bidirectional I/O, push pull output, high resistance input, and open drain.
Compared with Standard 51, the quasi bidirectional I/O mode differs in internal structure but is similar in usage. For example, when used as an input, it must first write “1” to set it to high level before reading the level state of the pin.!!!!! Why is it like this? Please refer to the diagram below for analysis.
The characteristic of push-3706A TRICONEX controllerpull output is that it can drive a large current regardless of whether it outputs high or low levels. For example, when outputting high levels, it can directly light up the LED (by connecting several hundred ohm current limiting resistors in series), which is difficult to achieve in quasi bidirectional I/O mode.
The characteristic of high impedance input mode is that it can only be used as an input, but it can obtain relatively high input impedance, which is necessary in analog comparator and ADC applications.
The open drain mode is similar to the quasi bidirectional mode, but there is no internal pull-up resistance. The advantage of open drain mode is good electrical compatibility. If the external pull-up resistor is connected to a 3V power supply, it can interface with a 3V logic device. If the pull-up resistor is connected to a 5V power supply, it can also interface with a 5V logic device. In addition, the open drain mode can also conveniently implement the “line and” logic function.
For the explanation of the above question, there is this information:
High resistance state is a common term in digital circuits, referring to an output state of a circuit that is neither high nor low. If the high resistance state is input into the next level circuit, it has no impact on the lower level circuit, just like not connected. If measured with a multimeter, it may be high or low, depending on what is connected afterwards.
High resistance states can be understood as open circuits during circuit analysis. You can think of it as having a very high output (input) resistance. His limit can be considered suspended.
Typical applications of high resistance states:
1. On the bus connected structure. There are multiple devices hanging on the bus, and the devices are connected to the bus in a high impedance form. This automatically releases the bus when the device does not occupy it, making it easier for other devices to gain access to the bus.
2. Most microcontroller I/O can be set to high impedance input when used, such as Lingyang, AVR, and so on. High resistance input can be considered as having infinite input resistance, indicating that I/O has minimal impact on the preceding stage and does not generate current (without attenuation), and to some extent, it also increases the chip”s resistance to voltage surges.

PCI-6033E
PCI-6032E
PCI-6031E
PCI-6030E
PCI-6025E
PCI-6024E
PCI-6023E
PCI-6011E
PCI-5922
PCI-5911
PCI-5640R
PCI-5640
PCI-5154
PCI-5153EX
PCI-5153
PCI-5152
PCI-5142
PCI-5124
PCI-5122EX
PCI-5122
PCI-5114
PCI-5112
PCI-5105
PCI-5102
PCI-4552
PCI-4551
PCI-4474
PCI-4472B
PCI-4472
PCI-4462
PCI-4461
PCI-4454
PCI-4452
PCI-4451
PCI-4070
PCI-4021
NI-9917
NI-9683
NI-9505
NI-9260 NI
ni-9250
NI-9234
Ni-9227
NI-9208
NI-9159
NI-9157
NI-9155
NI-9154
NI-9151
NI-9149
NI-9148
NI-9147
NI-9146
NI-9145
NI-9144
NI-5741
NI-5191
PXIE-2529
PXI-2520
USB-6525
PXIE-8840QC
PXIE-8840
PXIE-8135
PXIE-4081
pxie-4080
PXI-8461
PXI-6713
PXI-6683
PXI-6602
PXI-5402
PXI-2564
PXI-2510
PCIE-6321
NI-9216
GPIB-140A/2
FP-TB-1
CFP-DO-403
CFP-DO-400
CFP-DI-304
CFP-CB-1
CFP-AO-210
CFP-AO-200
CFP-AI-111
CFP-AI-100
CFP-1808
CFP-1804
AT-5102

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts