Sale!

9001NJ Invensys Triconex system

¥666.00

9001NJ Invensys Triconex system
Brand: TRICONEX
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

9001NJ Invensys Triconex system
9001NJ Invensys Triconex system
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com
Definition of IO Link Protocol and Its Interface
IO Link is a peer-to-peer, serial digital communication protocol designed for periodic data exchange between sensors/actuators and controllers (PLCs). The IO Link protocol was first proposed by Siemens and has now become an international standard IEC 61131-9. With the advancement of Industry 4.0, the use of IO Link is becoming increasingly widespread. Today”s article will introduce the definition of the IO Link protocol and its interfaces.
Factory automation can be divided into execution layer, on-site layer, on-site control layer, workshop control layer, and management layer according to functional division. As shown in the following figure:
The execution layer includes various execution mechanisms (valves, pumps, motors, etc.) and sensors, which are the muscles and peripheral nerves of factory automation. They receive commands from the upper layer and complete specified actions.
The on-9001NJ Invensys Triconex system  site layer includes various distributed IO9001NJ Invensys Triconex system systems, which are the central nervous system of factory automation. It conveys control instructions from the upper layer to the execution layer; And feedback the signals from the execution layer to the control layer, serving as the information center;
The on-site control layer includes various PLC systems, which are the brains of factory automation. It issues corresponding instructions and commands the execution layer to complete corresponding actions based on internal program requirements and signal feedback from the execution layer;
The workshop control layer (MES) and management layer communicate with various PLC systems at the management level to complete management tasks at the workshop and factory levels.
The IO Link protocol to be introduced in this article is a protocol that transfers data between the execution layer and the field layer. An IO Link system consists of the following components:
1) IO Link Master;
2) IO Link Device;
3) Non shielded 3-5 core standard cable;
4) Tools for configuring IO Link parameters;
The IO Link Master transfers data between the IO Link device and the PLC. It is usually a distributed IO module with IO Link connection channels on the module. The IO Link Device is connected to the channel of the IO Link Master through a cable, and the IO Link Master exchanges data with the PLC through a bus. As shown in the following figure:
Every IO Link device needs to be connected to a channel of the IO Link supervisor, so IO Link is a peer-to-peer communication protocol, not a bus protocol.
IO Link devices are divided into two types: sensors and actuators: sensors are usually the four pin interface of M12, and actuators are usually the five pin interface of M12.
According to IEC 60974-5-2, the definition of IO Link Device pins follows the following regulations:
1) Pin 1 (PIN1): 24V power supply positive pole;
2) Pin 3 (PIN3): 0V
3) Pin 4 (PIN4): IO Link communication or standard IO output;
The pin definition of the IO Link device is shown in the following figure:
Which types of equipment should PLC module manufacturers develop first?
We know that PLC, also known as programmable logic controller, collects variable data through various IOs to achieve the purpose of automated control. Therefore, developing PLC is largely about developing IO. However, with so many types of IO, which PLC module manufacturers should develop first? Let me share my opinion:
1. Digital input IO, including PNP and NPN digital input IO, counter input IO, etc.
2. Digital output IO, including PNP and NPN digital output IO, PWM pulse output IO, relay output IO, and so on.
3. Analog input IO, including current acquisition input IO, voltage acquisition input IO, temperature acquisition input IO, and so on. The current input IO can collect currents ranging from 0 to 20 milliamperes, while the voltage input IO can collect voltages ranging from negative 10V to positive 10V. Temperature acquisition IO includes thermocouples and thermal resistors.
4. The style of analog output IO is similar to that of analog input IO, but does not include temperature analog, mainly voltage and current type.
What are the types of integrated IO modules9001NJ Invensys Triconex system
For a programmable logic controller, IO fulfills the responsibilities of data acquisition and instruction output. What control objectives can a PLC achieve, and the quantity and type of IO are crucial. For general integrated PLCs, the number and types of IO interfaces are constant. Some friends may ask, what if you encounter a complex control project with insufficient IO ports in the PLC? Don”t worry, nowadays PLCs have communication interfaces that can be connected to other IO couplers to achieve IO expansion. So, what are the types of IO modules that we can integrate in our daily lives? Actually, it can be mainly divided into four categories, namely:
1. Digital signal acquisition IO can achieve discontinuous signal acquisition, and a typical IO type is a counter input IO module.
Technology Oasis • Source: Guangcheng CAN Bus • Author: Guangcheng CAN Bus • 2022-05-09 09:52 • 1740 readings
For a programmable logic controller, IO fulfills the responsibilities of data acquisition and instruction output. What control objectives can a PLC achieve, and the quantity and type of IO are crucial. For general integrated PLCs, the number and types of IO interfaces are constant. Some friends may ask, what if you encounter a complex control project with insufficient IO ports in the PLC? Don”t worry, nowadays PLCs have communication interfaces that can be connected to other IO couplers to achieve IO expansion. So, what are the types of IO modules that we can integrate in our daily lives? Actually, it can be mainly divided into four categories, namely:
1. Digital signal acquisition IO can achieve discontinuous signal acquisition, and a typical IO type is a counter input IO module.
2. Digital output IO, which can send out command signals of digital quantities to control actuators, such as PWM IO, can send pulse signals to control servo motors and stepper motors. In addition to PWM IO, we often use relay output type IO.
3. After discussing digital IO, let”s talk about analog IO. Firstly, analog input IO includes voltage analog input IO, current analog input IO, temperature analog input IO, etc. They collect continuous signals.
4. Finally, there is the output type IO of analog quantity, mainly including voltage analog quantity output type IO and current analog quantity output type IO. Some friends may ask why there is no temperature this time, but there are relatively few applications, mainly based on voltage and current types.9001NJ Invensys Triconex system
Industrial automation solutions, starting with remote IO modules!
The remote IO module is mainly used for collecting analog and digital signals on industrial sites, and can also output analog and digital signals to control equipment. It is possible to expand the input and output ports of data processing equipment such as PLCs and collection instruments. For example, a PLC only has 10 analog input interfaces, but if 30 analog quantities need to be collected on site, remote IO expansion needs to be added.
Furthermore, due to the distance between the equipment and the main control PLC or industrial computer, RS-485 bus is usually used for transmission. There are also some factories with high levels of automation that use industrial Ethernet to control remote IO modules. In the past, when laying lines between equipment and cabinets, people had to connect them one by one, which greatly increased the cost of cables and construction time. Moreover, if the distance was relatively long, they also faced problems such as voltage attenuation. And with the remote IO module, it effectively solves this problem. If your cabinet is 200 meters away from the site and you do not use remote IO, then you need to lay out each signal line for 200 meters. Installing the remote IO module on site can save you a lot of cable costs and reduce the complexity of construction from a cost perspective.
Simply put, sometimes some IO is set up in the on-site device cluster, which can be connected to the PLC through a communication cable to send the signal to any place where it is needed, saving wiring and PLC”s own IO points. Sometimes, the logical “remote” is because the allowed number of “local IO” cannot meet the actual needs, and it needs to be connected to the “remote IO template”, depending on the actual situation.
In addition, the general cabinet room is located on the device site. But some control signals, such as emergency stop and bypass, are implemented in the control room, so remote IO modules need to be used to send these signals to the control system in the cabinet room.
Why use remote I/O?
1. Because in some industrial applications, it is impossible to install PLCs with local I/O modules near on-site equipment due to harsh environments.
2. When you want to place the I/O module near the field device to eliminate long multi-core cables, you can receive signals from distant sensors and send remote control signals to control valves, motors, and other final actuators. The signal can be transmitted at any distance using various transmission protocols such as Ethernet and Profibus through high-speed media such as twisted pair and fiber optic.
3. Multiple transmission protocols such as Ethernet and Profibus can be used to send signals at any distance on high-speed media such as twisted pair and fiber optic.
The barium rhenium technology MXXT remote IO module uses industrial grade components with a wide working voltage of DC9-36V, which can operate normally within the range of -20~70 ℃. It supports RS485/232 communication mode, and the communication protocol adopts standard Modbus TCP protocol, Modbus RTU over TCP protocol, and MQTT protocol. We strive to fully meet the needs of our customers with an electrical and mechanical system that is anti-interference, resistant to harsh environments, and compatible with general use. It has stable performance, reliable quality, short delivery time, and fast response.
Advantages of Barium Rhenium Remote I/O Module
1. It can be controlled by remote commands.
2. Save the cost of using industrial control computers and IO cards, and Ethernet I/O modules can be directly connected to the upper computer system;
3. Replacing 4-20mA signal transmission with 10/100MHz Ethernet transmission has improved transmission speed;
4. Replacing various instrument controller signal lines with an Ethernet cable reduces the attenuation of remote signal transmission;
5. The signal cable of the instrument controller only needs to be connected to the Ethernet I/O module, greatly reducing cable costs and wiring workload.
6. Convenient installation method. Rail installation, high reliability, strong anti-interference ability, and more convenient on-site installation.
Is it better to have a higher number of IO module bit widths?
IO is an important component of PLC, and the collection of PLC information and the output of instructions must be applied to various input and output IO. I don”t know if you have read some IO user manuals. One of their instructions is the device”s bit width, such as 12 bits and 16 bits. So, is it better to have a higher number of bit widths for the IO module? Let”s talk about this matter.
Bit width is the number of bits of data that can be transmitted within a clock cycle, and the larger the number of bits, the greater the amount of data that can be transmitted instantly. From this perspective, the larger the bit width of the IO module, the better. This is not a problem. However, the amount of data transmission, also known as data bandwidth, depends not only on the bit width, but also on the frequency of data transmission. The multiplication of the two is the final total amount of data transmitted. That is to say, even if the light position is wide, but the frequency is too high, it still cannot work. At the same time, the larger the bit width, the higher the hardware cost, and the greater the heat generation and power consumption of the device.
How to Apply Ethernet IO Module to Weighbridge Data Collection9001NJ Invensys Triconex system
Weighbridge, a large scale set on the ground, usually used to weigh the tonnage of cargo carried by a truck. It is the main weighing equipment used for measuring bulk goods in factories, mines, merchants, etc. The MXXXX series of Ethernet IO modules with barium rhenium technology have rich IO ports that can be used to assist in data collection and transmission of the weighbridge, quickly achieving comprehensive management of data and control.
Before the vehicle enters the weighbridge, there will be an infrared sensor scanning about a few hundred meters. The infrared sensor will output a switch signal to the Ethernet IO module, indicating that a vehicle needs to enter. Before the vehicle officially enters the weighbridge for weighing, there will be an infrared barrier sensor scanning, and the barrier will also output a switch signal to the Ethernet IO module. When the vehicle is completely parked in front of the weighbridge (including whether the position is correct), the central control room will decide whether to start weighing based on the information received by the IO module from the radar sensor. Finally, the vehicle is weighed and drives away from the weighbridge. The scanning signal from the infrared barrier sensor at the exit is transmitted to the IO module, and the central control room controls the IO port of the IO module to open (close) the barrier. The green light will light up, and the vehicle will fully exit and leave the weighing weighbridge. The entire weighing process requires only one Ethernet IO module to collect information and control actions.9001NJ Invensys Triconex system
The MxxxT industrial remote Ethernet I/O data acquisition module adopts an industrial grade circuit design. The digital input adopts optocoupler isolation, providing 12 pulse counting inputs, supporting dry and wet contact input types. The analog input adopts operational amplifier isolation, supporting 12 bit high-precision data acquisition, compatible with 0~5V, 0~10V, 0~20mA, and 4~20mA input types. The DO output is a transistor Sink output, providing one channel of high-speed pulse output, The thermal resistance RTD input supports two types: PT100 and PT1000, and the analog AO output supports 0-10VDC output.
Pocket Io ™ The development platform has opened up numerous new avenues for experiencing the full power of Industry 4.0.
Compact design: compact structure, ultra small size, and overall dimensions (10 cubic inches: 3.5 “x 3.5” x 0.8 “).
Reliable and safe technology: Composed of advanced industrial products, all products have a rated working environment temperature of -40 ° C to+125 ° C, fully utilizing Maxim”s reliable, safe, and fast demagnetization technology.
Efficient: Ensure low power consumption and improve efficiency – no need for cooling fans.
Integrate numerous powerful interfaces: provide a complete set of 30 IOs for controlling the entire manufacturing node or a certain device, including: 4 analog inputs, 1 analog output, 8 digital inputs, 8 digital outputs, 2 RS-485 (compatible with Profibus fieldbus), 3 encoder/electrical control ports, and 4 IO Link hosts.
Long battery life: Firstly, the compact and portable PLC platform can work for up to 2 hours using “AA/AAA” type batteries, and 8 hours using LiFePO4 rechargeable batteries.
Programmable: It can be programmed through Arduino Sketch or using Intel”s Edison Eclipse IDE tool, supporting Windows, Linux, or Mac OS operating systems.
Easy to use: Sketches can be converted into apps and then downloaded to iPads ® Or iPhone ®  (Converted to an HMI panel for controlling Pocket IO).
What are the advantages of Ethernet remote IO modules that can be cascaded?
Advantages and specific application scenarios of Ethernet remote IO modules that can be cascaded
For scenarios where data collection control points are linearly distributed, such as streetlights, bridges, streetlights, digital factories, parking lot parking monitoring, smart parking lots, smart parking racks, and building automation control systems in smart parks, using cascading dual Ethernet remote IO modules saves more costs than using single Ethernet remote IO modules.
The Ethernet remote IO module that can be cascaded is a new type of Ethernet remote IO module that supports MAC layer data exchange and can achieve hand in hand connection. This not only saves switch interfaces, but also reduces a large amount of Ethernet cable costs, wiring space, and wiring costs.
Its advantages are as follows:
1. No need for a large number of Ethernet switches or occupying Ethernet switch ports;
2. It can save a lot of Ethernet cables, cable space, and labor costs for installing cables;
3. The overall cost has significantly decreased;
4. Supports both Modbus RTU protocol, Modbus TCP protocol, and the Internet of Things protocol MQTT protocol;
5. Support TCP Server and TCP Client services;
6. Can be connected to SCADA systems, PLC systems, or cloud platforms;
7. The series uses a MAC layer for data exchange, ensuring that network connectivity does not cause communication issues with subsequent devices due to device failures in the middle.
The comparison between cascaded Ethernet remote IO modules and traditional IO modules used in building automation systems is shown in the following figure:
1. Adopting a cascaded dual Ethernet remote IO module, data acquisition and control wiring for floors with a height of 70 meters only requires a 70 meter Ethernet cable;
2. Using a traditional single Ethernet remote IO module, the data acquisition and control system wiring for a 70 meter high floor requires a 280 meter Ethernet cable.
It can be seen that using cascaded dual Ethernet remote IO modules can save a lot of wiring costs compared to traditional single Ethernet remote IO modules.

5354 TRICONEX controller
9853-610 Safety Instrumented System (SIS)
87-008145-03 Invensys Triconex system
3636R TRICONEX controller
PLM 3900N TRICONEX controller
3708E Invensys Triconex system
3674 TRICONEX nput/output communication card
PS8310 TRICONEX controller
3721N TRICONEX controller
3625 TRICONEX nput/output communication card
3703E Safety Instrumented System (SIS)
3604E TRICONEX nput/output communication card
3006 Safety Instrumented System (SIS)
4000094-310 TRICONEX controller
3381 Invensys Triconex system
4000066-025 TRICONEX controller
3502EN2 TRICONEX controller
3664 Safety Instrumented System (SIS)
4200 Safety Instrumented System (SIS)
3721 Invensys Triconex system
PI3381 TRICONEX nput/output communication card
2290614 TRICONEX nput/output communication card
3806E Invensys Triconex system
3625A TRICONEX controller
8310N2 Safety Instrumented System (SIS)
3006 TRICONEX nput/output communication card
4107 Invensys Triconex system
3806E TRICONEX controller
2351 TRICONEX controller
4200 TRICONEX controller
9566-810F TRICONEX nput/output communication card
3720 TRICONEX controller
4107 TRICONEX nput/output communication card
8120E TRICONEX controller
3008N Safety Instrumented System (SIS)
3504E TRICONEX controller
HD8311 TRICONEX controller
4000093-110N TRICONEX nput/output communication card
7760059030 Safety Instrumented System (SIS)
3503E TRICONEX nput/output communication card
4107 Safety Instrumented System (SIS)

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts