Sale!

9566-810 TRICONEX nput/output communication card

¥666.00

9566-810 TRICONEX nput/output communication card
Brand: TRICONEX
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

9566-810 TRICONEX nput/output communication card
9566-810 TRICONEX nput/output communication card
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com
TRICONEX 3805E Invensys can accommodate the backplane of previous modules
TRICONEX 3805E Invensys can accommodate the backplane of previous modules
Fault tolerance in the TRICONEX 3805E is achieved through the the third mock examination redundancy (TMR) architecture. Tricon can provide error free and uninterrupted control in the event of hard faults or internal or external transient faults in components. Tricon adopts a completely triple architecture design, from the input module to the main processor and then to the output module. Each I/O module contains three independent branch circuits. Each pin on the input module reads process data and passes this information to their respective main processors. The three main processors communicate with each other using a proprietary high-speed bus system called TriBus. Every scan, the three main processors synchronize and communicate with their two neighbors through TriBus. Tricon votes on digital input data, compares output data, and sends copies of analog input data to each main processor. The main processor executes user written applications and sends the output generated by the application to the output module. In addition to voting on input data, TriBus also votes on output data. This is done on the output module as close to the field as possible to detect and compensate for any errors between the Tricon voting and the final output driven to the field.
The TRICONEX 3805E system typically consists of the following typical modules: [2]
Main processor modules (three).9566-810 TRICONEX nput/output communication card
Communication module.
Input and output modules: can be analog and/or digital, can work independently, or can be hot backup (backup).
Power module (redundant).9566-810 TRICONEX nput/output communication card
A backplane (chassis) that can accommodate previous modules.
System cabinet: One or more chassis can be compressed into one cabinet.
Organize cabinets to adapt and standardize interface connections between on-site instruments and Triconex system cabinets.
Human Machine Interface (HMI) for monitoring events.
Engineering Workstation (EWS) for programming. Monitoring, troubleshooting, and updating.
The remote IO module is designed according to the demanding industrial application environment requirements, embedded with a 32-bit high-performance microprocessor MCU, to meet various combinations of digital, analog, and thermal resistance IO modules. The communication protocol of the remote IO module adopts the standard Modbus TCP protocol, Modbus RTU over TCP protocol, and MQTT protocol. The remote IO module supports a wide working voltage of DC9-36V and has anti reverse protection function. It is equipped with a built-in watchdog and comprehensive lightning protection and anti-interference measures to ensure reliability.
The remote IO module supports 1 isolated 10/100M adaptive Ethernet interface with 15KV ESD protection, optocoupler isolated digital input, and supports dry wet contact input. The first channel can be used as pulse counting, supporting high-speed pulse and low-speed pulse modes. The default is high-speed pulse frequency with a maximum of 700KHz, and the optional low-speed pulse frequency with a maximum of 10KHz; DO output supports transistor Sink output, with the first channel available for high-speed pulse output, supporting pulse frequencies of 10Hz~300KHz; The remote IO module supports isolated 12 bit resolution analog input: 0-5V, 0-10V, 0-20mA, 4-20mA differential input; 1 channel RS485 communication interface, supporting standard Modbus RTU protocol for expansion; The thermal resistance RTD input supports two types: PT100 and PT1000;
What are the common types of IO extension modules? How much does an IO expansion module usually cost?
2. Analog Input Output Module: A module used to process and monitor analog signal input and output. Common analog input and output modules include modules based on resistors, transistors, and optocouplers.
3. Communication Interface Module: A module used to achieve communication between devices. Common communication interface modules include modules based on interfaces such as RS232, RS485, Ethernet, and CAN.
4. Special Function Module: A module used to implement specific functions. For example, the PWM (Pulse Width Modulation) module is used to control the speed and direction of the motor, and the counting module is used to achieve counting functions.
The price of IO expansion modules may vary depending on different brands, models, and functions.
Generally speaking, the price of more basic IO expansion modules ranges from tens to hundreds of yuan, while the price of IO expansion modules with more complex functions and stronger performance may be higher.
For example, the Io extension module ET1010 recently released by Zongheng Intelligent Control Company costs only 169 yuan per unit, and supports functions such as front-end and back-end cascading, sensorless expansion, and plug and play. It can be purchased in bulk or applied for a free trial address; The specific prices of these IO modules need to be queried and compared based on the specific modules you need.
Modify the watchdog time of the PROFINET IO device under 16 STEP7
3.2 Check if the installation of PROFINET IO communication equipment meets the specifications
Most cases of PROFINET IO communication interference problems are caused by equipment installation that does not comply with the installation specifications for PROFINET IO communication, such as incomplete shielding, unreliable grounding, and being too close to interference sources. Installation that meets the specifications can avoid communication failures caused by electromagnetic interference. You can refer to the following brief installation requirements for PROFINET:
1. Wiring of PROFINET 9566-810 TRICONEX nput/output communication card
In order to reduce the coupling of electric and magnetic fields, the larger the parallel distance between PROFINET and other power cable interference sources, the better. In accordance with IEC 61918, the minimum distance between PROFINET shielded cables and other cables can be referred to Table 1. PROFINET 9566-810 TRICONEX nput/output communication card can be wired together with other data cables, network cables, and shielded analog cables. If it is an unshielded power cable, the minimum distance is 200mm.
Comprehensive analysis of the principle and application skills of microcontroller IO port
IO port operation is the most basic and important knowledge in microcontroller practice. This article takes a long time to introduce the principles of IO ports. I also consulted a lot of materials to ensure the accuracy of the content, and spent a long time writing it. The principle of IO ports originally required a lot of in-depth knowledge, but here it has been simplified as much as possible for easy understanding. This will be of great help in solving various IO port related problems in the future.
The IO port equivalent model is my original method, which can effectively reduce the difficulty of understanding the internal structure of the IO port. And after consulting and confirming, this model is basically consistent with the actual working principle.
I mentioned a lot earlier, and many people may already be eager to actually operate microcontrollers. The IO port, as the main means of communication between the microcontroller and the outside world, is the most basic and important knowledge for microcontroller learning. Previously, we programmed and implemented an experiment to light up the LED at the IO port. This article will continue to introduce the relevant knowledge of the IO port.
In order to better learn the operation of IO ports, it is necessary to understand the internal structure and related concepts of IO ports. These knowledge are very helpful for subsequent learning, with a focus on understanding and no need to memorize them intentionally. If you don”t remember, just come back and take a look. If you use it too much, you will naturally remember.
We have said that the most accurate and effective way to understand a chip is to refer to official chip manuals and other materials. But for beginners of microcontrollers, it may be difficult to understand the chip manual directly, especially when they see a bunch of English, unfamiliar circuits, and terminology. If it were me, I would definitely be crazy. But here I still provide a picture taken from Atmel”s official “Atmel 8051 Microcontrollers Hardware Manual”.
The purpose of giving this picture is not to dampen everyone”s enthusiasm for learning, but to help everyone understand how the various microcontroller materials we have seen come from and whether they are accurate. All of these can be clarified through official information, which will be helpful for everyone to further learn something in the future.
Introduction to the Second Function
The above figure is the authoritative 51 microcontroller IO port structure diagram provided by the official. It can be seen that the internal structure of the four sets of IO ports of the microcontroller is different, because some IO ports have a secondary function, as mentioned in the introductory section.
Do you remember this pin diagram? The second function name of the IO port is marked in parentheses. Except for P1, each interface has a second function. When introducing the microcontroller system module, I mentioned that the 51 microcontroller has an interface for reserved extended memory, which is the second function of P0 and P1 in the figure (while also using pins such as 29 and 30). Because it is not widely used and involves in-depth knowledge, no specific research will be conducted. By the way, the AD0~AD7 we see here are actually used for parallel ports. The second function of the P3 port, including serial port, will be introduced in detail later.
The drawbacks of network IO and the advantages of multiplexing IO
In order to talk about multiplexing, of course, we still need to follow the trend and adopt a whiplash approach. First, we will talk about the drawbacks of traditional network IO and use the pull and step method to grasp the advantages of multiplexing IO.
For the convenience of understanding, all the following code is pseudo code, and it is sufficient to know the meaning it expresses.
Blocking IO
The server wrote the following code to handle the data of client connections and requests.
Listenfd=socket()// Open a network communication port
Bind (listenfd)// binding
Listen (listenfd)// Listening while (1){
Connfd=accept (listenfd)// Blocking connection establishment
Int n=read (connfd, buf)// Blocking read data
DoSomeThing (buf)// What to do with the data you read
Close (connfd)// Close the connection and wait for the next connection in a loop
}
This code will be executed with stumbling blocks, just like this.
It can be seen that the thread on the server is blocked in two places, one is the accept function and the other is the read function.
If we expand on the details of the read function again, we will find that it is blocked in two stages.
This is traditional blocking IO.
The overall process is shown in the following figure.
So, if the client of this connection continues to not send data, the server thread will continue to block on the read function and not return, nor will it be able to accept other client connections.
This is definitely not feasible.
Non blocking IO
To solve the above problem, the key is to modify the read function.
A clever approach is to create a new process or thread every time, call the read function, and perform business processing.
While (1){
Connfd=accept (listenfd)// Blocking connection establishment
Pthread_ Create (doWork)// Create a new thread
}
Void doWork(){
Int n=read (connfd, buf)// Blocking read data
DoSomeThing (buf)// What to do with the data you read
Close (connfd)// Close the connection and wait for the next connection in a loop
}
In this way, once a connection is established for a client, it can immediately wait for a new client connection without blocking the read request from the original client.
However, this is not called non blocking IO, it just uses multithreading to prevent the main thread from getting stuck in the read function and not going down. The read function provided by the operating system is still blocked.
So true non blocking IO cannot be achieved through our user layer tricks, but rather by imploring the operating system to provide us with a non blocking read function.
The effect of this read function is to immediately return an error value (-1) when no data arrives (reaches the network card and is copied to the kernel buffer), rather than waiting for blocking.
The operating system provides this feature by simply setting the file descriptor to non blocking before calling read.
Fcntl (connfd, F_SETFL, O_NONBLOCK);
Int n=read (connfd, buffer)= SUCCESS;
In this way, the user thread needs to loop through the call to read until the return value is not -1, and then start processing the business.
We noticed a detail here.
Non blocking read refers to the stage where data is non blocking before it reaches the network card, or before it reaches the network card but has not been copied to the kernel buffer.
When the data has reached the kernel buffer, calling the read function is still blocked and requires waiting for the data to be copied from the kernel buffer to the user buffer before returning.
The overall process is shown in the following figure
IO multiplexing
Creating a thread for each client can easily deplete the thread resources on the server side.
Of course, there is also a clever solution. After accepting each client connection, we can put the file descriptor (connfd) into an array.
Fdlist. add (connfd);
Then create a new thread to continuously traverse the array and call the non blocking read method for each element.
While (1){
For (fd “- fdlist){
If (read (fd)!=- 1){
DoSomeThing();
}
}
}
In this way, we successfully processed multiple client connections with one thread.
Do you think this means some multiplexing?
But this is just like using multithreading to transform blocked IO into seemingly non blocking IO. This traversal method is just a small trick that our users have come up with, and every time we encounter a read that returns -1, it is still a system call that wastes resources.
Making system calls in a while loop is not cost-effective, just like making rpc requests while working on distributed projects.
So, we still need to plead with the operating system boss to provide us with a function that has such an effect. We will pass a batch of file descriptors to the kernel through a system call, and the kernel layer will traverse them to truly solve this problem.
What is the difference between remote IO and distributed IO
People often discuss the difference between remote IO and distributed IO. However, some people believe that they are the same and terms can be exchanged, while others believe the opposite. What is the difference between remote I/O and distributed I/O? The following is a guide from remote IO manufacturer Zhongshan Technology to understand the difference between remote IO and distributed IO.
Remote and distributed within the location range.9566-810 TRICONEX nput/output communication card
Today”s DCS is a control system with many distributed autonomous controllers, each with many continuous operations. This controller is bundled together by a central monitoring controller. We have used the terms remote and distributed in the locations of I/O and controllers. It is easy to see how these terms are misunderstood.
From the perspective of PLC, remote I/O represents the actual distance that the I/O module is away from the control PLC. Distributed I/O is very intelligent, as mentioned earlier, remote I/O is sometimes referred to as distributed I/O. Let”s take a look at the definition of distributed I/O. This definition is different from remote I/O.
Generally speaking, distributed I/O has a brain or some computing power. By default, it is remote. As mentioned earlier, remote I/O is located physically far from the control PLC. Remote I/O has no brain and cannot perform any computational functions at all. It can be said with certainty that when you hear the term remote I/O, it only involves one controller or PLC, while distributed I/O has multiple controllers.
ZSR-Ethernet-2184 is a distributed Ethernet RTU that supports 4-way switch digital input (Di), 8-way analog input (Ai), 4-way relay (Do) output, 1-way RS485 serial port data acquisition to Ethernet, and Modbus RTU terminal. Merge 485 to Ethernet serial port server function, support Modbus to TCP/UDP protocol conversion, support virtual serial port, and interface with various configuration software. Supports signal acquisition in the range of 0-5V, 0-10V, 0-30V, or 0-20ma, 4-20ma, with built-in software and hardware watchdog, industrial grade components, and stable operation in an industrial environment of -40~85 ° C.
Building a High Channel Density Digital IO Module for the Next Generation Industrial Automation Controller
There are currently many articles introducing Industry 4.0, and smart sensors are becoming increasingly popular in factory environments (I and other authors have written about these topics). Although we have all noticed a significant increase in the use of sensors in factories, processing plants, and even some newly built automation systems, the widespread use of sensors has also brought about an important change, which is the need to handle a large amount of IO within these old controllers. These IOs may be digital or analog. This requires the construction of high-density IO modules with size and heat limitations.
Usually, digital IO in PLC consists of discrete devices such as resistors/capacitors or independent FET drives. In order to minimize the size of the controller as much as possible and to handle 2 to 4 times the number of channels, this has led to a shift from a separate approach to an integrated approach.9566-810 TRICONEX nput/output communication card
We can use the entire article to illustrate the drawbacks of the split method, especially when the number of channels processed by each module reaches 8 or more. However, when it comes to high heat/power consumption, a large number of split components (from the perspective of size and mean time between failures (MTBF)), and the need for reliable system specifications, it is sufficient to demonstrate that the split method is not feasible.
Figure 1 shows the technical challenges faced in building high-density digital input (DI) and digital output (DO) modules. In both DI and DO systems, size and heat dissipation issues need to be considered.
Design a High Channel Density Digital Input Module
The traditional split design uses a resistive voltage divider network to convert 24V/48V signals into signals that can be used by microcontrollers. The front-end can also use discrete RC filters. If isolation is required, external optocouplers are sometimes used
For example, the current limiting value of DI devices in ADI is 3.5mA/channel. So, as shown in the figure, we use two channels in parallel. If the system must be connected to a Type 2 input, adjust the REFDI resistance and RIN resistance. For some newer components, we can also use pins or select current values through software.
To support a 48V digital input signal (not a common requirement), a similar process needs to be used, and an external resistor must be added to adjust the voltage threshold at one end of the field. Set the value of this external resistor so that the current limiting value * R+threshold of the pin meets the voltage threshold specification at one end of the field (see device data manual).
Finally, due to the connection between the digital input module and the sensor, the design must meet the requirements of reliable operating characteristics. When using a split type scheme, these protective functions must be carefully designed. When selecting integrated digital input devices, ensure that the following are determined according to industry standards:
Wide input voltage range (e.g. up to 40V).
Able to use on-site power supply (7V to 65V).
Capable of withstanding high ESD (± 15kV ESD air gap) and surges (usually 1KV).
Providing overvoltage and overheating diagnosis is also very useful for MCU to take appropriate actions.
Design a High Channel Density Digital Output Module
A typical discrete digital output design has a FET with a driving circuit driven by a microcontroller. Different methods can be used to configure FETs to drive microcontrollers.
The definition of a high-end load switch is that it is controlled by an external enable signal and connects or disconnects the power supply from a given load. Compared to low-end load switches, high-end switches provide current to the load, while low-end switches connect or disconnect the grounding connection of the load to obtain current from the load. Although they all use a single FET, the problem with low-end switches is that there may be a short circuit between the load and ground. High end switches protect the load and prevent short circuits to ground. However, the implementation cost of low-end switches is lower. Sometimes, the output driver is also configured as a push-pull switch, requiring two MOSFETs. Refer to Figure 4 below.
Integrated DO devices can integrate multiple DO channels into a single device. Due to the different FET configurations used for high-end, low-end, and push-pull switches, different devices can be used to achieve each type of output driver.
How to Build High Channel Density Digital IO Modules for the Next Generation Industrial Automation Controllers
With the rapid development of industrial automation, digital IO modules have become an indispensable part of industrial automation controllers. The digital IO module can connect the controller with external devices, such as sensors, actuators, etc., to achieve monitoring and control of industrial production processes. However, with the continuous development of industrial automation, digital IO modules need to have higher channel density and stronger functionality to meet the needs of new industrial automation controllers. Therefore, it is very important to build high channel density digital IO modules for the next generation of industrial automation controllers.
The digital IO module is one of the most fundamental modules in industrial automation controllers, and its main function is to connect the controller with external devices to achieve signal input and output. The digital IO module usually includes two parts: a digital input module and a digital output module. The digital input module can convert the digital signals of external devices into signals that the controller can read, while the digital output module can convert the digital signals output by the controller into signals that external devices can read. The channel density of a digital IO module refers to the number of digital input or digital output channels provided on the module, which is the input and output capacity of the module.
With the development of industrial automation, digital IO modules need to have higher channel density and stronger functions to meet the needs of new industrial automation controllers. The following are several aspects to consider when building a high channel density digital IO module for the next generation of industrial automation controllers:9566-810 TRICONEX nput/output communication card
1. Choose the appropriate communication protocol
Digital IO modules typically communicate with controllers through communication protocols, so choosing a suitable communication protocol is crucial. Common communication protocols include Modbus, Profibus, CANopen, Ethernet, etc. Different communication protocols have different advantages and disadvantages, and selecting a suitable communication protocol requires considering the following factors:
(1) Communication speed: The faster the communication speed, the shorter the response time of the digital IO module, which can process input and output signals faster.
(2) Communication distance: The farther the communication distance, the wider the application range of digital IO modules.
(3) Reliability: The reliability of communication protocols determines the stability and reliability of digital IO modules.
(4) Cost: Different communication protocols have different costs, and suitable communication protocols need to be selected based on actual needs.
2. Choose the appropriate digital IO chip
The digital IO chip is the core component of the digital IO module, and its performance and function directly affect the channel density and function of the digital IO module. Choosing a suitable digital IO chip requires considering the following factors:
(1) Channel density: The channel density of digital IO chips determines the channel density of digital IO modules, and channel density needs to be selected based on actual needs.
(2) Input/output type: Digital IO chips usually support digital input and digital output, and some chips also support functions such as analog input and output, counters, etc.
(3) Speed: The speed of the digital IO chip determines the response speed of the digital IO module, and it is necessary to choose a chip with a faster speed.
(4) Accuracy: The accuracy of digital IO chips determines the signal accuracy of digital IO modules, and it is necessary to choose chips with higher accuracy.
(5) Cost: Different digital IO chips have different costs, and suitable chips need to be selected based on actual needs.
3. Optimize circuit design
The circuit design of digital IO modules has a significant impact on their performance and stability. In order to improve the channel density and functionality of digital IO modules, it is necessary to optimize circuit design, such as:
(1) Using high-speed digital IO chips: Using high-speed digital IO chips can improve the response speed and accuracy of the module.
(2) Adopting anti-interference design: In order to improve the stability of the digital IO module, it is necessary to adopt anti-interference design, such as using filters, isolators, etc.
(3) Using optimized PCB layout: Optimizing PCB layout can reduce noise and interference in digital IO modules, improve module performance and stability.
4. Choose the appropriate shell material and size
Digital IO modules typically need to be installed in cabinets or control cabinets, so choosing the appropriate housing material and size is crucial. The shell material should have good protective and heat dissipation properties to protect the circuits of the digital IO module from external environmental influences. The shell size should be able to adapt to different installation environments, such as cabinets, control cabinets, etc.
5. Optimize software design
The software design of the digital IO module determines its functionality and performance. In order to achieve high channel density and stronger functionality, it is necessary to optimize software design, such as:
(1) Supporting multiple input and output types: Supporting multiple input and output types can meet different application needs, such as digital input and output, analog input and output, counters, etc.
(2) Supporting multiple communication protocols: Supporting multiple communication protocols can adapt to different controllers and application environments.
(3) Support for online debugging and monitoring: Supporting online debugging and monitoring can facilitate user diagnosis and maintenance of modules.
(4) Support for expansion function: Supporting expansion function can increase the functionality and application range of the module while ensuring channel density.
In summary, building a high channel density digital IO module for the next generation of industrial automation controllers requires multiple considerations, including selecting suitable communication protocols, selecting suitable digital IO chips, optimizing circuit design, selecting suitable shell materials and sizes, and optimizing software design. Only by comprehensively considering these factors can a digital IO module with high channel density and stronger functionality be constructed to meet the needs of new industrial automation controllers.
How to assign IO devices to IO controllers?
PROFINET IO system
The PROFINET IO system consists of a PROFINET IO controller and its assigned PROFINET IO devices. After adding IO controllers and IO devices, it is necessary to assign IO controllers to the IO devices to form a basic PROFINET IO system.
Prerequisite requirements
● Already in the network view of STEP 7.
A CPU has been placed (e.g. CPU 1516-3 PN/DP).
● An IO device has been placed (e.g. IM 155-6 PN ST)
Operating Steps (Method 1)
To assign IO devices to IO controllers, follow these steps:
1. Move the mouse pointer over the interface of the IO device.
2. Hold down the left mouse button.
3. Drag the mouse pointer.
The pointer will now use the networking symbol to indicate the “networking” mode. At the same time, you can see a lock character appearing on the pointer
Number. The lock symbol only disappears when the pointer moves to a valid target position.
4. Now, move the pointer to the interface of the desired IO controller and release the left mouse button.
5. Now assign the IO device to the IO controller.
Operating Steps (Method 2)
To assign IO devices to IO controllers, follow these steps:
1. Move the mouse pointer over the word “Unassigned” in the bottom left corner of the IO device icon.
2. Click the left mouse button.
3. Select the IO controller interface to be connected from the available interfaces that appear.
4. Now assign the IO device to the IO controller.

F8650X HIMA security module
Z7306 HIMA security module
BT21LE/S HIMA DO digital output
X-BASE-PLATE-18-01 HIMA DO digital output
F3330 HIMA DO digital output
F8616 Germany HIMA
K9202B Germany HIMA
Z7149 Germany HIMA
ZBT-F 9402 Digital input module HIMA
F6214 HIMA DO digital output
F3240 Digital input module HIMA
K9203 HIMA DO digital output
X-AO1601 Germany HIMA
F3246A HIMA DO digital output
F3322 HIMA security module
F8650 HIMA security module
F3414 Germany HIMA
F8650E HIMA security module
F3332 HIMA DO digital output
F3331 Germany HIMA
Bv7044 HIMA security module
F7120 HIMA security module
F3DIO20/802 HIMA security module
F8011006A SMU1-1 HIMA security module
F5203 HIMA DO digital output
F8627X Digital input module HIMA
42400 Germany HIMA
F-COM 01 Digital input module HIMA
F3322 Digital input module HIMA
F8640 Digital input module HIMA
F3348 HIMA security module
F35 982200416 HIMA DO digital output
Z7136 HIMA DO digital output
F6706 Digital input module HIMA
K9202 HIMA security module
F7113 HIMA security module
ELOPII HIMA security module
F7529 HIMA security module
F3334 HIMA DO digital output
F5109B HIMA DO digital output
Z7138 HIMA DO digital output
H4135 HIMA security module
F3236 HIMA security module
F-CPU01 Germany HIMA
H4136 HIMA security module
F3223 HIMA DO digital output
F6217 Germany HIMA
F8652X Digital input module HIMA
X-CPU 01 HIMA security module
F8627X HIMA DO digital output
F8627X HIMA security module
F3430 HIMA security module
F8650X Germany HIMA
F5109B HIMA security module
F7126 HIMA DO digital output
F8620/11 Germany HIMA
F7126 Germany HIMA

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts