Description
3500/05-02-02 Transient Data Interface BENTLY
3500/05-02-02 Transient Data Interface BENTLY
Module Clips Drive controller servo moto
The 3500/05-02-02 EGD Communication Gateway Integrates process control and other automation systems using both Ethernet TCP/IP and serial (RS232 / RS422 / RS485) communications capabilities. Permits Ethernet communications with 3500 Rack Configuration Software. The 3500/05-02-02 also supports proprietary Bently Nevada protocol along with Modicon Modbus and Modbus/TCP protocols.
3500/05-02-02Communication Gateway integrates easily with process control networks and other automation systems using both Ethernet TCP/IP and serial (RS232 / RS422 / RS485) communications capabilities. Permits communications via Modbus using 3500 Rack Configuration Software. The 3500/05-02-02 can be configured using the 3500 Rack Configuration software to produce a custom or condensed Modbus map for communications using fixed or configurable registers. All vital rack information including direct vibration, gap, 1X, 2X, Smax, channel statuses, rack status, trip multiply, rack reset, and others can be easily communicated.
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn’t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot’s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
ABB AX670 3BSE000566R1 Analog Mixed Module
ELAU ISH100/30025/0/0/00/0/00/00/00 motor
AE APEX3013(0190-53914)Radio frequency power supply
ICS TRIPLEX T8403C Digital Input Module
5SHY3545L0009 3BHB013085R0001 3BHE009681R0101 GVC750BE101
AMAT COMPONENT SIDE Control panel
A-B 1756-A7 rack
140CPU65160 Unity processor Modicon Quantum
REXRTOH VT-HNC100-1-23/W-08-P-0 R00958999 Servo controller
VT-HNC100-2-30/P-I-00/G02 R901134616
4WE6Y62/EG24N9K4 R900561276 + HSZ10-26916-AA/G24N9K4M01 R901025684
ABB 5SGY3545L0009 3BHL000986P3004 IGCT module
IS220PAICH1A 336A4940CSP3 Analog input/output module
133442-01 Bently Nevada I/O Module 3500/55M
ABB 5SHY35L4503 3BHB004693R0001 3BHB004692R0002 5SXE01-0127
PHARPS03000000 ABB Power module
VT-HNC100-1-23/W-08-P-0 R00958999
TRICONEX 3501TN2 Digital Input Module
Allen-Bradley 1336-BDB-SP70C PCB grid driver board
TRICONEX 4000103-510N cable
Allen-Bradley 1336-BDB-SP72D 1336 PCB Boards
Allen-Bradley 1336-BDB-SP44C Printed circuit board
Allen-Bradley 1336-BDB-SP30C Door drive PCB
SM812 3BSE072270R1 AC 800M HI controller SM812K01
CI874 3BSE090784R1 AC 800M Communication interface module CI874A
CI873A 3BSE092695R1 AC 800M Communication interface module CI873
CI873 3BSE056899R1 AC 800M Communication interface module CI873A
CI871 3BSE056767R1 AC 800M Communication interface module CI871A
CI871A 3BSE092693R1 AC 800M Communication interface module CI871
CI869 3BSE049110R1 AC 800M Communication interface module CI869A
CI868A 3BSE092691R1 AC 800M Communication interface module CI868
CI868 3BSE048845R1 AC 800M Communication interface module CI868A
CI867A 3BSE092689R1 AC 800M Communication interface module CI867
CI858 3BSE018135R1 AC 800M Communication interface module CI858A
CI865 3BSE040795R1 AC 800M Communication interface module CI865A
CI857 3BSE0184414R1 AC 800M Communication interface module CI857A
CI856 3BSE026055R1 AC 800M Communication interface module CI856A
CI855K01 3BSE018106R1 AC 800M Communication interface module CI855A
Allen-Bradley 1336S-MCB-SP1B PC main control board
CI854B 3BSE069449R1 AC 800M Communication interface module CI854BK01
CI854A 3BSE030220R1 AC 800M Communication interface module CI854AK01
CI853 3BSE018103R1 AC 800M Communication interface module CI853K01
TB826 3BSE061637R1 S800 I/O process system
TB840A 3BSE037760R1 S800 I/O process system
TB825 3BSE036634R1 S800 I/O process System
TB820V2 3BSE013208R1 S800 I/O process system
CI845 3BSE075853R1 S800 I/O process System
CI840A 3BSE041882R1 S800 I/O process System
CI773F 3BDH000395R0001 PROFIBUS DP Main module AC900F
PM904F 3BDH001002R0001 AC 900F Controller PM901F
PM901F 3BDH001001R0005 AC 900F controller
CI910F 3BDH001005R0001 CAN Communication interface module
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit
Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts