Sale!

3300/14 Temperature monitor BENTLY

¥900.00

3300/14 Temperature monitor BENTLY
Brand: BENTLY
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

3300/14 Temperature monitor BENTLY
3300/14 Temperature monitor BENTLY
Module Clips Drive controller servo moto

The 3300/14 EGD Communication Gateway Integrates process control and other automation systems using both Ethernet TCP/IP and serial (RS232 / RS422 / RS485) communications capabilities. Permits Ethernet communications with 3500 Rack Configuration Software. The 3300/14 also supports proprietary Bently Nevada protocol along with Modicon Modbus and Modbus/TCP protocols.

3300/14Communication Gateway integrates easily with process control networks and other automation systems using both Ethernet TCP/IP and serial (RS232 / RS422 / RS485) communications capabilities. Permits communications via Modbus using 3500 Rack Configuration Software. The 3300/14 can be configured using the 3500 Rack Configuration software to produce a custom or condensed Modbus map for communications using fixed or configurable registers. All vital rack information including direct vibration, gap, 1X, 2X, Smax, channel statuses, rack status, trip multiply, rack reset, and others can be easily communicated.

Contact: Mr. Lai 
Wechat:17750010683 
Whats app:+86 17750010683 
Skype:+86 17750010683 
QQ: 3221366881 
3221366881@qq.com

https://www.xmamazon.com

https://www.xmamazon.com

Home

Home

https://www.plcdcs.com/

www.module-plc.com/

https://www.ymgk.com

(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;

(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. , so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to the frequency converter;

(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time communication effect.

4 Inverter operation settings

After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system, appropriate parameter settings must also be performed on each frequency converter.

After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.

4.1 Basic settings

(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the user. If this parameter is not defined, communication between the module and the drive cannot be established.

(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.

(3) 51.03—This parameter is Profibu

The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.

(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]

4.2 Connection of process parameters

The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency converter to the master station (PLC). Set the following connection parameters on the frequency converter.

(1) PZD value sent from PLC to transmission inverter

PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;

PZD2—frequency setting value of the inverter.

(2) PZD value sent from the transmission inverter to the PLC

PZD1—status word, such as alarm, fault and other inverter operating status;

PZD2—actual speed value, current actual value, etc. of the frequency converter.

5 Conclusion

After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful example for the future automation equipment (network communication of different manufacturers) of the head office.

New technology from Swiss ABB Group: Complete car charging in 15 seconds

This technology can charge a car in 15 seconds

The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company’s battery technology can achieve this performance.

ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its minimal design will help protect the urban environment and surrounding landscape.

The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called TOSA to obtain electricity from clean hydroelectric power stations.

ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.

ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”

8280-1099 723PLUS Standard Generator Control
8280-1076 load sharing control
8280-1056 Digital control unit for redundant load distribution
8280-1042 Single Engine Digital Speed Controller
8280-1009 Numerical Control Model
8280-1001 723PLUS Digital Controller
8262-092 digital control
8237-1278 versatile Woodward DSLC/MSLC Gateway Control
8237-1277 gateway controller
8230-3012 723PLUS Generator Control
8230-3011 WOODWARD digital controller
9907-171 operator control panel
9907-170 Woodward 505E Microprocessor Based Control Unit
9907-169 Digital Control of Turbines
9907-166 Woodward 505E 32-bit microprocessor
9907-167 505E Series Digital Control Equipment
9907-165 32-bit microcontroller
8200-1302 505 Digital Governor
9907-1183 32-bit microcontroller
8200-1300 Gas turbines provide digital control
9907-164 505 and 505E Governor Control Units
9907-163 Governor Control Unit
9907-162 Controls for 505 and 505E Models
FBM24 PM900HT Contact/DC Input
FBM22 PM900HS Auto/Manual Station
FBM21 PM700TW 240 Vac Input Expander
FBM20 PM700QV 240 Vac input
FBM18 PM400YV  Smart Transmitter I/O
FBM17 PM400YT 0-10 Vdc, Contact/DC I/O
FBM16 PM400YS 240 Vac I/O Expander
FBM15 CM400YR 120 Vac I/O Expander
FBM201D Analog Input Interface Modules
FBM207B Voltage Monitor / Contact Sense Input Modules
216NG62A HESG441634R1/K HESG216876 processor module
FBM231 P0926GV Field Device System Integrator Module
P0400YF PSS 21H-2B8 B4 FBM05 Redundant 0 to 20 mA I/O Interface
P0400YD FBM03 PSS 21H-2B5 B4 RTD Input Interface Module
FBM233 P0926GX Ethernet Communication
P0914YM FCM10E Fieldbus Communications Module
FBM01 Foxboro  Input Interface Module
FBM216 Communication Redundant Input Interface Module
FBM230 Master (Serial and TCP/IP) Driver
FBM201 Foxboro Analog Input Interface Modules
P0916BX Foxboro Termination Assembly
216VC62A HESG324442R13/C processor unit
FBM217 foxboro Discrete Input Interface Module
FBM211 FOXBORO Input Interface Module
FBM242 Foxboro Discrete Output Interface Module
FBM205 P0914XG FOXBORO I/O Interface Module
FBM237 P0914XS Channel Isolated Output Interface Module

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts