Sale!

3401 TRICONEX controller

¥666.00

3401 TRICONEX controller
Brand: TRICONEX
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

3401 TRICONEX controller
3401 TRICONEX controller
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com
TRICONEX 3805E Invensys can accommodate the backplane of previous modules
TRICONEX 3805E Invensys can accommodate the backplane of previous modules
Fault tolerance in the TRICONEX 3805E is achieved through the the third mock examination redundancy (TMR) architecture. Tricon can provide error free and uninterrupted control in the event of hard faults or internal or external transient faults in components. Tricon adopts a completely triple architecture design, from the input module to the main processor and then to the output module. Each I/O module contains three independent branch circuits. Each pin on the input module reads process data and passes this information to their respective main processors. The three main processors communicate with each other using a proprietary high-speed bus system called TriBus. Every scan, the three main processors synchronize and communicate with their two neighbors through TriBus. Tricon votes on digital input data, compares output data, and sends copies of analog input data to each main processor. The main processor executes user written applications and sends the output generated by the application to the output module. In addition to voting on input data, TriBus also votes on output data. This is done on the output module as close to the field as possible to detect and compensate for any errors between the Tricon voting and the final output driven to the field.
The TRICONEX 3805E system typically consists of the following typical modules: [2]
Main processor modules (three).3401 TRICONEX controller
Communication module.
Input and output modules: can be analog and/or digital, can work independently, or can be hot backup (backup).
Power module (redundant).3401 TRICONEX controller
A backplane (chassis) that can accommodate previous modules.
System cabinet: One or more chassis can be compressed into one cabinet.
Organize cabinets to adapt and standardize interface connections between on-site instruments and Triconex system cabinets.
Human Machine Interface (HMI) for monitoring events.
Engineering Workstation (EWS) for programming. Monitoring, troubleshooting, and updating.
The remote IO module is designed according to the demanding industrial application environment requirements, embedded with a 32-bit high-performance microprocessor MCU, to meet various combinations of digital, analog, and thermal resistance IO modules. The communication protocol of the remote IO module adopts the standard Modbus TCP protocol, Modbus RTU over TCP protocol, and MQTT protocol. The remote IO module supports a wide working voltage of DC9-36V and has anti reverse protection function. It is equipped with a built-in watchdog and comprehensive lightning protection and anti-interference measures to ensure reliability.
The remote IO module supports 1 isolated 10/100M adaptive Ethernet interface with 15KV ESD protection, optocoupler isolated digital input, and supports dry wet contact input. The first channel can be used as pulse counting, supporting high-speed pulse and low-speed pulse modes. The default is high-speed pulse frequency with a maximum of 700KHz, and the optional low-speed pulse frequency with a maximum of 10KHz; DO output supports transistor Sink output, with the first channel available for high-speed pulse output, supporting pulse frequencies of 10Hz~300KHz; The remote IO module supports isolated 12 bit resolution analog input: 0-5V, 0-10V, 0-20mA, 4-20mA differential input; 1 channel RS485 communication interface, supporting standard Modbus RTU protocol for expansion; The thermal resistance RTD input supports two types: PT100 and PT1000;
What are the common types of IO extension modules? How much does an IO expansion module usually cost?
2. Analog Input Output Module: A module used to process and monitor analog signal input and output. Common analog input and output modules include modules based on resistors, transistors, and optocouplers.
3. Communication Interface Module: A module used to achieve communication between devices. Common communication interface modules include modules based on interfaces such as RS232, RS485, Ethernet, and CAN.
4. Special Function Module: A module used to implement specific functions. For example, the PWM (Pulse Width Modulation) module is used to control the speed and direction of the motor, and the counting module is used to achieve counting functions.
The price of IO expansion modules may vary depending on different brands, models, and functions.
Generally speaking, the price of more basic IO expansion modules ranges from tens to hundreds of yuan, while the price of IO expansion modules with more complex functions and stronger performance may be higher.
For example, the Io extension module ET1010 recently released by Zongheng Intelligent Control Company costs only 169 yuan per unit, and supports functions such as front-end and back-end cascading, sensorless expansion, and plug and play. It can be purchased in bulk or applied for a free trial address; The specific prices of these IO modules need to be queried and compared based on the specific modules you need.
What is the function of an IO chip
Io generally refers to input and output devices, where I is the input and O is the output. The input to the IO port of the chip is the external signal transmission to the chip, while the output is the internal signal transmission to other devices. The input and output are relative. In short, in a broad sense, the control of input and output interfaces is called an IO chip, and network cards are also considered IO or array cards.
The CPU must read and write data to external registers or ROMs on RAM or other hardware through IO commands (such as input/output commands). For example, reading a keyboard involves accessing external registers on the keyboard through the 60H port, and the chip on the keyboard scans the keyboard. Pressing or holding down a key for a long time will cause the chip to generate corresponding scan or break codes, which will be written to the external register of the 60H port, so that the CPU can achieve the purpose of controlling the keyboard. Therefore, I think IO chips should refer to a large category. The CPU already has powerful IO instructions and corresponding control buses.
51 microcontroller IO port input and output mode_ Four usage methods for IO ports
The traditional 51 microcontroller IO interface can only be used as a standard bidirectional IO interface. If it is used to drive LED, it can only be driven by injecting current or using a transistor external expansion drive circuit.
Current injection method: LED positive pole connected to VCC, negative pole connected to IO port. If the IO is at a high level, the two poles of the LED are at the same level, and there is no current, the LED will turn off; IO is at low power level, current flows from VCC to IO, and LED lights up. But when you connect the positive pole of the LED to the IO interface and the negative pole to GND, placing the IO interface at a high level will cause the LED to light up. However, due to the insufficient pull-up capability of the IO interface, the brightness is not ideal. The following method can be used to solve this problem.
Push-pull working mode: The positive and negative poles of the LED are connected to two IO ports, and then the positive IO interface is set as the push-pull output, while the negative IO interface is set as the standard bidirectional current input. The push pull method has strong pull-up ability and can achieve high-level LED driving.
Four usage methods for IO ports3401 TRICONEX controller
From the perspective of the characteristics of the I/O port, the P0 port of Standard 51 is an open drain structure when used as an I/O port, and in practical applications, a pull-up resistor is usually added; P1, P2, and P3 are all quasi bidirectional I/Os with internal pull-up resistors, which can be used as both input and output. The I/O port characteristics of the LPC900 series microcontroller have certain differences, and they can be configured into four different working modes: quasi bidirectional I/O, push pull output, high resistance input, and open drain.
Compared with Standard 51, the quasi bidirectional I/O mode differs in internal structure but is similar in usage. For example, when used as an input, it must first write “1” to set it to high level before reading the level state of the pin.!!!!! Why is it like this? Please refer to the diagram below for analysis.
The characteristic of push-3401 TRICONEX controllerpull output is that it can drive a large current regardless of whether it outputs high or low levels. For example, when outputting high levels, it can directly light up the LED (by connecting several hundred ohm current limiting resistors in series), which is difficult to achieve in quasi bidirectional I/O mode.
The characteristic of high impedance input mode is that it can only be used as an input, but it can obtain relatively high input impedance, which is necessary in analog comparator and ADC applications.
The open drain mode is similar to the quasi bidirectional mode, but there is no internal pull-up resistance. The advantage of open drain mode is good electrical compatibility. If the external pull-up resistor is connected to a 3V power supply, it can interface with a 3V logic device. If the pull-up resistor is connected to a 5V power supply, it can also interface with a 5V logic device. In addition, the open drain mode can also conveniently implement the “line and” logic function.
For the explanation of the above question, there is this information:
High resistance state is a common term in digital circuits, referring to an output state of a circuit that is neither high nor low. If the high resistance state is input into the next level circuit, it has no impact on the lower level circuit, just like not connected. If measured with a multimeter, it may be high or low, depending on what is connected afterwards.
High resistance states can be understood as open circuits during circuit analysis. You can think of it as having a very high output (input) resistance. His limit can be considered suspended.
Typical applications of high resistance states:
1. On the bus connected structure. There are multiple devices hanging on the bus, and the devices are connected to the bus in a high impedance form. This automatically releases the bus when the device does not occupy it, making it easier for other devices to gain access to the bus.
2. Most microcontroller I/O can be set to high impedance input when used, such as Lingyang, AVR, and so on. High resistance input can be considered as having infinite input resistance, indicating that I/O has minimal impact on the preceding stage and does not generate current (without attenuation), and to some extent, it also increases the chip”s resistance to voltage surges.
What exactly does embedded development do?
Embedded development is a technology similar to programming, but our understanding of the scope of programmers is to do computer software, web development, and also to do apps.
The majority of embedded development is intelligent electronic products, which are designed for hardware programming. This hardware can be understood as a circuit board, usually composed of a controller (processor) chip and different circuits.
The specific program and circuit are generally determined by the product function. For example, an electronic clock product is usually composed of a digital tube and a microcontroller (controller), and then written in C language to download it to the microcontroller to achieve clock display.3401 TRICONEX controller
Of course, there are far more products that can be developed in embedded systems, including smartphones, wearable devices, drones, robots, mice and keyboards, and so on.
The knowledge system of embedded development and design is also very diverse, and different products require different learning contents.
So, if we want to enter embedded development, we must first understand several directions of embedded development, otherwise you will never find a starting point.
The general mainstream directions are microcontroller development, ARM+Linux development, and FPGA/DSP development.
I have been working on microcontroller development for the past 10 years of my career.
Microcontrollers can be said to be the foundation of all directions. If you have strong microcontroller development capabilities, then ARM+Linux, or FPGA/DSP are easy for you to get started.
The development of microcontrollers is also one of the directions with the lowest threshold for embedded systems. Initially, I was self-taught in electrical engineering and transferred there. It took me about four months from the beginning of my studies to finding a job.
However, at that time, the threshold was still very low, and you could basically find a job by working on a small project with a 51 microcontroller.
If it”s the current situation, you only know these things and have little competitiveness. Nowadays, the main focus of enterprises is on whether you have project experience, rather than what kind of microcontroller you know.
The project experience can be accumulated through practical projects with endless microcontroller programming, which can be said to be the closest to actual development at present.
At present, the salary of single-chip microcontrollers is not low, and it is normal for them to start at 8K in first tier cities, and they can reach 15K after working for 2-3 years.
There are many industries covered by embedded systems, and in the later stage, based on work, we will only focus on one direction. From a macro perspective, we will divide it into embedded software development and embedded hardware development. Software development is mainly based on application software development on systems (Linux, VxWorks, WinCE, etc.), and hardware development includes motherboard design, system porting, cutting, and writing low-level drivers
My personal experience started with microcontrollers. Firstly, I studied C and C++, digital and analog electronics, power electronics, circuit design, microcontroller principles, FreeRTOS, data structures, and computer operating systems. Later, due to work requirements, I relearned university automation control theory, signals and systems, complex functions, linear algebra, calculus, statistics, and compiler principles. These are all basics, and it is important to understand and thoroughly study them, This will bring help to the later research and development work, and there is also a need for more drawing board, drawing board, and practical operation. Without practicing optics, the efficiency is very low, and knowledge is repetitive. Only by repeatedly looking and using can we understand. We can buy some development boards to assist in learning. Now that the internet is developed, network resources can improve our learning efficiency.
Embedded development refers to developing under an embedded operating system, commonly used systems include WinCE, ucos, vxworks, Linux, Android, etc. In addition, develop using C, C++, or assembly; Using advanced processors such as arm7, arm9, arm11, powerpc, mips, mipsel, or operating systems also belongs to embedded development.
1. Basic knowledge:
Purpose: I can understand the working principles of hardware, but the focus is on embedded software, especially operating system level software, which will be my advantage.
Subjects: Digital Circuits, Principles of Computer Composition, and Embedded Microprocessor Architecture.
Assembly Language, C/C++, Compilation Principles, Discrete Mathematics.
Data structure and algorithms, operating systems, software engineering, networks, databases.
Method: Although there are many subjects, they are all relatively simple foundations and most of them have been mastered. Not all courses may be taught, but elective courses can be taken as needed.
Main books: The C++programming language (I haven”t had time to read it), Data Structure-C2.
2. Learning Linux:
Purpose: To gain a deeper understanding of the Linux system.
Method: Using Linux ->Linxu system programming development ->Driver development and analysis of the Linux kernel. Let”s take a closer look, then the main topic is principles. After reading it a few times, look at the scenario analysis and compare it deeply. The two books intersect, with depth being the outline and emotion being the purpose. Analysis is version 0.11, suitable for learning. Finally, delve into the code.
Main books: Complete Analysis of Linux Kernel, Advanced Programming in Unix Environment, Deep Understanding of Linux Kernel, Scenario Analysis, and Source Generation.
3. Learning embedded Linux:
Purpose: To master embedded processors and their systems.
Method: (1) Embedded microprocessor structure and application: Direct arm principle and assembly are sufficient, without repeating x86.
(2) Embedded operating system class: ucOS/II is simple, open source, and easy to get started. Then delve deeper into uClinux.
(3) Must have a development board (arm9 or above) and have the opportunity to participate in training (fast progress, able to meet some friends).
Main books: Mao Decao”s “Embedded Systems” and other arm9 manuals and arm assembly instructions.
Application of Data Acquisition IO Module in Thermal Power Plant System3401 TRICONEX controller
The Ethernet IO module is a data acquisition and control device. It uses Ethernet as a communication method to transmit data from various industrial control sensors and actuators to computers or other devices for management and monitoring. As a modern energy supply base, thermal power plants need to widely apply various intelligent control technologies to improve operational efficiency, reduce costs, and improve safety. In this context, the application of barium rhenium Ethernet IO modules is particularly important.
In the application of thermal power plants, the main function of the barium rhenium Ethernet IO module is to achieve real-time monitoring and control of the production process. By connecting to various sensors and actuators, the barium rhenium Ethernet IO module can collect real-time environmental parameters, machine operation status, and other data of the thermal power plant. By analyzing and processing these data, commanders can understand the operation of the thermal power plant and make corresponding adjustments. Compared to traditional automatic control systems, the barium rhenium Ethernet IO module has the advantages of stronger flexibility, faster reaction speed, and higher accuracy, which can greatly improve the operational efficiency and reliability of thermal power plants.
The real-time monitoring and control of thermal power plants require many capabilities of barium rhenium Ethernet IO modules. Here are several common application scenarios:
Firstly, the barium rhenium module can monitor parameters such as gas flow and water flow in thermal power plants. These parameters are crucial for ensuring the normal operation of the thermal power plant. Once these parameters undergo abnormal changes, the DO channel can be connected to the barium rhenium Ethernet IO module, and the alarm signal will immediately sound to remind the command personnel to handle it. Meanwhile, due to the fact that the barium rhenium Ethernet IO module can collect these data in real-time and transmit it to the monitoring system for recording, it can provide better technical support for quality management in thermal power plants.
Secondly, the barium rhenium Ethernet IO module can also monitor the operating status of mechanical equipment in thermal power plants. This includes parameters such as temperature, pressure, vibration, etc. By monitoring and analyzing these parameters, the barium rhenium Ethernet IO module can detect machine equipment faults in a timely manner, thereby avoiding the expansion of losses. In addition, during machine equipment maintenance, historical data recorded by the barium rhenium Ethernet IO module can be used to develop more scientific and reasonable maintenance plans, reduce maintenance costs, and improve maintenance efficiency.
Finally, the barium rhenium Ethernet IO module can also help thermal power plants achieve distributed control. We can remotely control and monitor multiple areas of the thermal power plant by connecting multiple barium rhenium modules to a network. This not only reduces the on-site debugging of equipment, but also strengthens the evaluation of equipment reliability.
In summary, the barium rhenium Ethernet IO module has unique advantages in real-time monitoring and control of thermal power plants. It can help command personnel monitor machine data in real-time, discover abnormal information, take timely measures to avoid impacts, and improve production efficiency and safety.
Remote IO modules based on Ethernet communication are widely used in the field of industrial IoT
With the development of IIOT (Industrial IOT) industrial Internet of Things technology, many traditional assets need to be connected to the internet to achieve unified data collection, analysis, processing, and storage, breaking the traditional phenomenon of device information silos. Therefore, the MQTT Ethernet IO acquisition module M160T, which supports the Internet of Things protocol, is able to unleash its potential by being compatible with existing devices and able to connect to IoT platforms. The MQTT Ethernet IO acquisition module will be widely used in industrial IoT, such as smart property, smart parks, smart factories, smart transportation, smart water conservancy, smart agriculture, smart campuses, smart communities, smart distribution, smart water conservancy, and many other industries.
Ethernet communication technology is a mature communication technology that has been widely applied. Therefore, Ethernet communication is the first choice for enterprises to connect various assets to the Internet of Things platform. Its reasons are stable and reliable, mature technology, fast transmission speed, and fast construction wiring.3401 TRICONEX controller
For traditional various assets, such as low-voltage distribution rooms, air compressor rooms, property and living pump rooms, street light control, liquid level collection, temperature and humidity collection, etc., through the MQTT Ethernet IO collection module, they can be quickly connected to the Internet of Things platform.
So, what characteristics do MQTT Ethernet IO modules need to have when used in IoT solutions? The details are as follows:
1. Actively connect to cloud platforms:
Based on the characteristics of Ethernet communication networking, the Ethernet IO acquisition module must support the TCP Client function, which is not only the TCP client function, so that the Ethernet IO module can actively connect to the IoT platform without the need for complex settings such as peanut shells;
2. Compatible with existing systems:
Support TCP Server and Modbus TCP protocol functions, which can be compatible with traditional upper computer systems or device access of HMI”s TCP client;
3. Access to IoT platforms:
Supports standard MQTT protocol and Modbus TCP protocol, and can be connected to various MQTT protocol IoT platforms such as Huawei Cloud and Alibaba Cloud, or traditional SCADA and DCS systems;
4. Rich IO interfaces and scalability:
There are various types of data to be collected on site, and it is necessary to support the collection of various devices such as 4-20Ma, RS485, DI, DO, etc. At the same time, it is also necessary to have the ability to read RS485 device instrument data or expand the functions of the IO acquisition module;
5. Easy installation method:
The volume of the control box is very limited, so it is necessary to use directly inserted and unplugged wiring terminals, as well as a rail installation method.
6. Industrial grade design
The industrial environment is harsh, and the Ethernet IO module must adopt an industrial grade design to ensure continuous and stable operation in harsh environments.
Through the MQTT Ethernet IO acquisition module, there is no need to replace various existing enterprise assets and the digital transformation of accessing IoT platforms can be quickly achieved. Therefore, the MQTT Ethernet IO acquisition module will be widely used in industrial IoT, such as smart properties, smart parks, smart factories, smart transportation, smart water conservancy, smart agriculture, smart campuses, smart communities, smart power distribution, smart water conservancy, and many other industries.

2290614 Safety Instrumented System (SIS)
3704E TRICONEX controller
3301 TRICONEX nput/output communication card
3703E TRICONEX controller
EPI3382 Invensys Triconex system
3504E Invensys Triconex system
MP3101 TRICONEX nput/output communication card
3504E TRICONEX nput/output communication card
8312 TRICONEX nput/output communication card
3708E TRICONEX controller
3503E Invensys Triconex system
4352AN Invensys Triconex system
4211 TRICONEX controller
7760059030 TRICONEX nput/output communication card
4000093-145 Safety Instrumented System (SIS)
9761-210 TRICONEX nput/output communication card
4351B TRICONEX nput/output communication card
3721C TRICONEX controller
3720 Safety Instrumented System (SIS)
3708E Safety Instrumented System (SIS)
3506X Safety Instrumented System (SIS)
8111 TRICONEX nput/output communication card
2401 Safety Instrumented System (SIS)
8310N2 TRICONEX nput/output communication card
4352B TRICONEX controller
3704E Invensys Triconex system
4000066-025 Invensys Triconex system
8120E Safety Instrumented System (SIS)
8120E Invensys Triconex system
4000093-145 TRICONEX nput/output communication card
T8461 TRICONEX nput/output communication card
4000103-510 Safety Instrumented System (SIS)
3700A Invensys Triconex system
3721 TRICONEX controller
3009 Invensys Triconex system
4000093-110N Safety Instrumented System (SIS)
3664 TRICONEX controller
3708EN Invensys Triconex system
MP3101S2 TRICONEX controller
3005 Invensys Triconex system
3481 TRICONEX controller
3708E TRICONEX nput/output communication card
4000093-510 TRICONEX controller
3008 Safety Instrumented System (SIS)
AO3481 TRICONEX controller
3564 Safety Instrumented System (SIS)
9761-210 Invensys Triconex system
4119 TRICONEX controller
3101 Safety Instrumented System (SIS)
9662-810 TRICONEX controller
EPI3382 TRICONEX controller
9566-810 Safety Instrumented System (SIS)
3502EN2 Safety Instrumented System (SIS)
4210 TRICONEX controller
4329 TRICONEX controller
3009 Safety Instrumented System (SIS)
3604E Safety Instrumented System (SIS)
3502E Invensys Triconex system
3006 Invensys Triconex system
HD8311 Safety Instrumented System (SIS)
3564 TRICONEX nput/output communication card
4000093-510 Safety Instrumented System (SIS)
3481 Invensys Triconex system
3481 TRICONEX nput/output communication card
3005 Safety Instrumented System (SIS)

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts