Description
3806E Invensys Triconex system
3806E Invensys Triconex system
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com
What are the types of integrated IO modules3806E Invensys Triconex system
For a programmable logic controller, IO fulfills the responsibilities of data acquisition and instruction output. What control objectives can a PLC achieve, and the quantity and type of IO are crucial. For general integrated PLCs, the number and types of IO interfaces are constant. Some friends may ask, what if you encounter a complex control project with insufficient IO ports in the PLC? Don”t worry, nowadays PLCs have communication interfaces that can be connected to other IO couplers to achieve IO expansion. So, what are the types of IO modules that we can integrate in our daily lives? Actually, it can be mainly divided into four categories, namely:
1. Digital signal acquisition IO can achieve discontinuous signal acquisition, and a typical IO type is a counter input IO module.
Technology Oasis • Source: Guangcheng CAN Bus • Author: Guangcheng CAN Bus • 2022-05-09 09:52 • 1740 readings
For a programmable logic controller, IO fulfills the responsibilities of data acquisition and instruction output. What control objectives can a PLC achieve, and the quantity and type of IO are crucial. For general integrated PLCs, the number and types of IO interfaces are constant. Some friends may ask, what if you encounter a complex control project with insufficient IO ports in the PLC? Don”t worry, nowadays PLCs have communication interfaces that can be connected to other IO couplers to achieve IO expansion. So, what are the types of IO modules that we can integrate in our daily lives? Actually, it can be mainly divided into four categories, namely:
1. Digital signal acquisition IO can achieve discontinuous signal acquisition, and a typical IO type is a counter input IO module.
2. Digital output IO, which can send out command signals of digital quantities to control actuators, such as PWM IO, can send pulse signals to control servo motors and stepper motors. In addition to PWM IO, we often use relay output type IO.
3. After discussing digital IO, let”s talk about analog IO. Firstly, analog input IO includes voltage analog input IO, current analog input IO, temperature analog input IO, etc. They collect continuous signals.
4. Finally, there is the output type IO of analog quantity, mainly including voltage analog quantity output type IO and current analog quantity output type IO. Some friends may ask why there is no temperature this time, but there are relatively few applications, mainly based on voltage and current types.3806E Invensys Triconex system
Industrial automation solutions, starting with remote IO modules!
The remote IO module is mainly used for collecting analog and digital signals on industrial sites, and can also output analog and digital signals to control equipment. It is possible to expand the input and output ports of data processing equipment such as PLCs and collection instruments. For example, a PLC only has 10 analog input interfaces, but if 30 analog quantities need to be collected on site, remote IO expansion needs to be added.
Furthermore, due to the distance between the equipment and the main control PLC or industrial computer, RS-485 bus is usually used for transmission. There are also some factories with high levels of automation that use industrial Ethernet to control remote IO modules. In the past, when laying lines between equipment and cabinets, people had to connect them one by one, which greatly increased the cost of cables and construction time. Moreover, if the distance was relatively long, they also faced problems such as voltage attenuation. And with the remote IO module, it effectively solves this problem. If your cabinet is 200 meters away from the site and you do not use remote IO, then you need to lay out each signal line for 200 meters. Installing the remote IO module on site can save you a lot of cable costs and reduce the complexity of construction from a cost perspective.
Simply put, sometimes some IO is set up in the on-site device cluster, which can be connected to the PLC through a communication cable to send the signal to any place where it is needed, saving wiring and PLC”s own IO points. Sometimes, the logical “remote” is because the allowed number of “local IO” cannot meet the actual needs, and it needs to be connected to the “remote IO template”, depending on the actual situation.
In addition, the general cabinet room is located on the device site. But some control signals, such as emergency stop and bypass, are implemented in the control room, so remote IO modules need to be used to send these signals to the control system in the cabinet room.
Why use remote I/O?
1. Because in some industrial applications, it is impossible to install PLCs with local I/O modules near on-site equipment due to harsh environments.
2. When you want to place the I/O module near the field device to eliminate long multi-core cables, you can receive signals from distant sensors and send remote control signals to control valves, motors, and other final actuators. The signal can be transmitted at any distance using various transmission protocols such as Ethernet and Profibus through high-speed media such as twisted pair and fiber optic.
3. Multiple transmission protocols such as Ethernet and Profibus can be used to send signals at any distance on high-speed media such as twisted pair and fiber optic.
The barium rhenium technology MXXT remote IO module uses industrial grade components with a wide working voltage of DC9-36V, which can operate normally within the range of -20~70 ℃. It supports RS485/232 communication mode, and the communication protocol adopts standard Modbus TCP protocol, Modbus RTU over TCP protocol, and MQTT protocol. We strive to fully meet the needs of our customers with an electrical and mechanical system that is anti-interference, resistant to harsh environments, and compatible with general use. It has stable performance, reliable quality, short delivery time, and fast response.
Advantages of Barium Rhenium Remote I/O Module
1. It can be controlled by remote commands.
2. Save the cost of using industrial control computers and IO cards, and Ethernet I/O modules can be directly connected to the upper computer system;
3. Replacing 4-20mA signal transmission with 10/100MHz Ethernet transmission has improved transmission speed;
4. Replacing various instrument controller signal lines with an Ethernet cable reduces the attenuation of remote signal transmission;
5. The signal cable of the instrument controller only needs to be connected to the Ethernet I/O module, greatly reducing cable costs and wiring workload.
6. Convenient installation method. Rail installation, high reliability, strong anti-interference ability, and more convenient on-site installation.
What are the advantages of Ethernet remote IO modules that can be cascaded?
Advantages and specific application scenarios of Ethernet remote IO modules that can be cascaded
For scenarios where data collection control points are linearly distributed, such as streetlights, bridges, streetlights, digital factories, parking lot parking monitoring, smart parking lots, smart parking racks, and building automation control systems in smart parks, using cascading dual Ethernet remote IO modules saves more costs than using single Ethernet remote IO modules.
The Ethernet remote IO module that can be cascaded is a new type of Ethernet remote IO module that supports MAC layer data exchange and can achieve hand in hand connection. This not only saves switch interfaces, but also reduces a large amount of Ethernet cable costs, wiring space, and wiring costs.
Its advantages are as follows:3806E Invensys Triconex system
1. No need for a large number of Ethernet switches or occupying Ethernet switch ports;
2. It can save a lot of Ethernet cables, cable space, and labor costs for installing cables;
3. The overall cost has significantly decreased;
4. Supports both Modbus RTU protocol, Modbus TCP protocol, and the Internet of Things protocol MQTT protocol;
5. Support TCP Server and TCP Client services;3806E Invensys Triconex system
6. Can be connected to SCADA systems, PLC systems, or cloud platforms;
7. The series uses a MAC layer for data exchange, ensuring that network connectivity does not cause communication issues with subsequent devices due to device failures in the middle.
The comparison between cascaded Ethernet remote IO modules and traditional IO modules used in building automation systems is shown in the following figure:
1. Adopting a cascaded dual Ethernet remote IO module, data acquisition and control wiring for floors with a height of 70 meters only requires a 70 meter Ethernet cable;
2. Using a traditional single Ethernet remote IO module, the data acquisition and control system wiring for a 70 meter high floor requires a 280 meter Ethernet cable.
It can be seen that using cascaded dual Ethernet remote IO modules can save a lot of wiring costs compared to traditional single Ethernet remote IO modules.
Application of Ethernet Remote IO Module in Building Automation System
For building automation systems, each data acquisition control point is linearly distributed in each floor. Therefore, it is very suitable to use Ethernet remote IO modules that can be cascaded to achieve data acquisition and control.
The Ethernet remote IO module that can be cascaded supports MAC layer data exchange and can achieve a hand in hand connection method. This can not only save switch interfaces, but also reduce a large amount of Ethernet cable costs, wiring space, and wiring costs.
Its advantages are as follows:
1. No need for a large number of Ethernet switches or occupying Ethernet switch ports;
2. It can save a lot of Ethernet cables, cable space, and labor costs for installing cables;
3. The overall cost has significantly decreased;
4. The M160E supports both Modbus RTU protocol, Modbus TCP protocol, and the Internet of Things protocol MQTT protocol. In addition, it also supports TCP Server and TCP Client services; Can be connected to SCADA systems, PLC systems, or cloud platforms;
4. The M160E series uses a MAC layer for data exchange, ensuring that network connectivity does not cause communication issues with subsequent devices due to device failures in the middle.
Comparison between cascaded Ethernet remote IO modules and traditional IO modules for building automation systems:
1. Adopting a cascaded dual Ethernet remote IO module, data acquisition and control wiring for floors with a height of 70 meters only requires a 70 meter Ethernet cable;
2. Using a traditional single Ethernet remote IO module, the data acquisition and control system wiring for a 70 meter high floor requires a 280 meter Ethernet cable.
Therefore, we can conclude that for scenarios where data collection control points are linearly distributed, such as streetlights, bridges, streetlights, digital factories, parking lot parking monitoring, smart parking lots, smart parking racks, and building automation systems in smart parks, using cascading dual Ethernet remote IO modules saves more costs than using single Ethernet remote IO modules.
Application of Data Acquisition IO Module in Thermal Power Plant System3806E Invensys Triconex system
The Ethernet IO module is a data acquisition and control device. It uses Ethernet as a communication method to transmit data from various industrial control sensors and actuators to computers or other devices for management and monitoring. As a modern energy supply base, thermal power plants need to widely apply various intelligent control technologies to improve operational efficiency, reduce costs, and improve safety. In this context, the application of barium rhenium Ethernet IO modules is particularly important.
In the application of thermal power plants, the main function of the barium rhenium Ethernet IO module is to achieve real-time monitoring and control of the production process. By connecting to various sensors and actuators, the barium rhenium Ethernet IO module can collect real-time environmental parameters, machine operation status, and other data of the thermal power plant. By analyzing and processing these data, commanders can understand the operation of the thermal power plant and make corresponding adjustments. Compared to traditional automatic control systems, the barium rhenium Ethernet IO module has the advantages of stronger flexibility, faster reaction speed, and higher accuracy, which can greatly improve the operational efficiency and reliability of thermal power plants.
The real-time monitoring and control of thermal power plants require many capabilities of barium rhenium Ethernet IO modules. Here are several common application scenarios:
Firstly, the barium rhenium module can monitor parameters such as gas flow and water flow in thermal power plants. These parameters are crucial for ensuring the normal operation of the thermal power plant. Once these parameters undergo abnormal changes, the DO channel can be connected to the barium rhenium Ethernet IO module, and the alarm signal will immediately sound to remind the command personnel to handle it. Meanwhile, due to the fact that the barium rhenium Ethernet IO module can collect these data in real-time and transmit it to the monitoring system for recording, it can provide better technical support for quality management in thermal power plants.
Secondly, the barium rhenium Ethernet IO module can also monitor the operating status of mechanical equipment in thermal power plants. This includes parameters such as temperature, pressure, vibration, etc. By monitoring and analyzing these parameters, the barium rhenium Ethernet IO module can detect machine equipment faults in a timely manner, thereby avoiding the expansion of losses. In addition, during machine equipment maintenance, historical data recorded by the barium rhenium Ethernet IO module can be used to develop more scientific and reasonable maintenance plans, reduce maintenance costs, and improve maintenance efficiency.
Finally, the barium rhenium Ethernet IO module can also help thermal power plants achieve distributed control. We can remotely control and monitor multiple areas of the thermal power plant by connecting multiple barium rhenium modules to a network. This not only reduces the on-site debugging of equipment, but also strengthens the evaluation of equipment reliability.
In summary, the barium rhenium Ethernet IO module has unique advantages in real-time monitoring and control of thermal power plants. It can help command personnel monitor machine data in real-time, discover abnormal information, take timely measures to avoid impacts, and improve production efficiency and safety.
Remote IO modules based on Ethernet communication are widely used in the field of industrial IoT
With the development of IIOT (Industrial IOT) industrial Internet of Things technology, many traditional assets need to be connected to the internet to achieve unified data collection, analysis, processing, and storage, breaking the traditional phenomenon of device information silos. Therefore, the MQTT Ethernet IO acquisition module M160T, which supports the Internet of Things protocol, is able to unleash its potential by being compatible with existing devices and able to connect to IoT platforms. The MQTT Ethernet IO acquisition module will be widely used in industrial IoT, such as smart property, smart parks, smart factories, smart transportation, smart water conservancy, smart agriculture, smart campuses, smart communities, smart distribution, smart water conservancy, and many other industries.
Ethernet communication technology is a mature communication technology that has been widely applied. Therefore, Ethernet communication is the first choice for enterprises to connect various assets to the Internet of Things platform. Its reasons are stable and reliable, mature technology, fast transmission speed, and fast construction wiring.3806E Invensys Triconex system
For traditional various assets, such as low-voltage distribution rooms, air compressor rooms, property and living pump rooms, street light control, liquid level collection, temperature and humidity collection, etc., through the MQTT Ethernet IO collection module, they can be quickly connected to the Internet of Things platform.
So, what characteristics do MQTT Ethernet IO modules need to have when used in IoT solutions? The details are as follows:
1. Actively connect to cloud platforms:
Based on the characteristics of Ethernet communication networking, the Ethernet IO acquisition module must support the TCP Client function, which is not only the TCP client function, so that the Ethernet IO module can actively connect to the IoT platform without the need for complex settings such as peanut shells;
2. Compatible with existing systems:
Support TCP Server and Modbus TCP protocol functions, which can be compatible with traditional upper computer systems or device access of HMI”s TCP client;
3. Access to IoT platforms:
Supports standard MQTT protocol and Modbus TCP protocol, and can be connected to various MQTT protocol IoT platforms such as Huawei Cloud and Alibaba Cloud, or traditional SCADA and DCS systems;
4. Rich IO interfaces and scalability:
There are various types of data to be collected on site, and it is necessary to support the collection of various devices such as 4-20Ma, RS485, DI, DO, etc. At the same time, it is also necessary to have the ability to read RS485 device instrument data or expand the functions of the IO acquisition module;
5. Easy installation method:
The volume of the control box is very limited, so it is necessary to use directly inserted and unplugged wiring terminals, as well as a rail installation method.
6. Industrial grade design
The industrial environment is harsh, and the Ethernet IO module must adopt an industrial grade design to ensure continuous and stable operation in harsh environments.
Through the MQTT Ethernet IO acquisition module, there is no need to replace various existing enterprise assets and the digital transformation of accessing IoT platforms can be quickly achieved. Therefore, the MQTT Ethernet IO acquisition module will be widely used in industrial IoT, such as smart properties, smart parks, smart factories, smart transportation, smart water conservancy, smart agriculture, smart campuses, smart communities, smart power distribution, smart water conservancy, and many other industries.
What IO combinations can a mini PLC combine with to achieve automated control?
At present, there are two main design modes for controllers like PLC, one is integrated design and the other is modular design. From the name, we can feel that there are two different PLCs, one that cannot be disassembled and the other that can be disassembled. Due to the fact that the main control module and IO module of the modular PLC can be spliced as needed, its volume and weight are usually very small, and we cannot call it a mini PLC too much. So, what IO combinations can such a small gadget combine with to achieve automation control? Let”s take a brief inventory:3806E Invensys Triconex system
1. Firstly, there is the digital quantity acquisition IO module, which is used to collect digital quantity information. Typical examples include counter IO, PNP type digital quantity acquisition IO, NPN type digital quantity acquisition IO, etc.
2. Then there is the digital output IO module, which is used to send digital instructions. The most typical example is PWM output IO, which can output pulse signals to control servo motors or stepper motors for operation.
3. After talking about digital IO, let”s talk about analog IO. Analog signal acquisition type IO includes voltage signal acquisition, current signal acquisition, and temperature signal acquisition. The IO for collecting temperature signals includes PT100, PT1000, and various thermocouple temperature acquisition modules.
4. Finally, there are analog output IO, as well as output current signals and voltage signals.
In addition to the above IO modules, our modular PLC also supports extended communication interfaces, further enhancing the equipment”s scalability.
Module Input/Output (I/O) Knowledge3806E Invensys Triconex system
Module Input/Output (I/O) Knowledge
I think it”s necessary to talk about the sorting of the input and output ports of the module. Generally, we can divide it into IO functional division and IO specifications.
The purpose of the former is mainly to convert all functions into actual division into MCU IO ports, while the purpose of the latter is to determine the specifications of all IO ports. Of course, you can completely skip these tasks, and it”s also possible. Depending on the company”s requirements, I think individuals still consider them as a work habit.
The following examples are all created for my blog post. If there are any duplicate names, please do not contact me.
Looking at the above figure, first determine all input and output functions and power input, as well as communication.
Then separate the power distribution with different lines, and start organizing each power supply line and processing process. The final purpose of the entire diagram is to clearly allocate the input and output sequence.
The IO specification is to provide a detailed description of all interfaces, crystal oscillators, and other information to the MCU.
1. Enter the number of low effective interfaces and how much pull-up resistance (switch wet current) is required (how much current does the microcontroller need to absorb, which may be injected into the microcontroller after pull-up).
2. Enter the number of highly effective interfaces, how many pull-down resistors are required (switch wet current), (how much current does the microcontroller need to absorb, and it is possible to inject the microcontroller after the switch is effective)
3. Number of analog input interfaces, evaluate whether the analog ports of the microcontroller are sufficient, and confirm the required analog conversion accuracy. Evaluate whether the A/D conversion reference voltage needs to be replaced (to meet accuracy requirements). Consider how many power supplies need to be tested and how many analog input ports are configured.
4. Evaluate the requirements for crystal oscillator accuracy and whether a phase-locked loop is required.
The above requirements are mainly aimed at module design and need to be confirmed during the early development of the module. All requirements can be organized using an Excel table and displayed in the diagram.
Distributed dual Ethernet IO module
The distributed dual Ethernet IO module adopts an industrial grade design, which meets the demanding industrial application scenarios. It is equipped with a dedicated high-performance Ethernet chip, which can quickly achieve cascade networking between IO modules without the need for repeated wiring, saving on-site wiring costs.
The distributed dual Ethernet IO module comes with switch input, switch output, relay output, analog input, analog input, thermal resistance input, etc. It supports high-speed pulse input counting and high-speed pulse output, and is designed specifically for industrial field data collection, measurement, and control. The distributed dual Ethernet IO module supports Modbus TCP protocol and Modbus RTU protocol for uplink, which can quickly connect to existing DCS, SCADA, PLC, HMI and other systems. The distributed dual Ethernet IO module supports one RS485 interface and supports Modbus RTU Master function. It can expand the IO module, read and write intelligent instrument data, or connect to HMI, DCS, PLC and other devices as a Modbus Slave.
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit
Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts