Sale!

4000098-510 TRICONEX controller

¥666.00

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

4000098-510 TRICONEX controller
4000098-510 TRICONEX controller
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com
What are the characteristics of a demonstration system based on IO Link slave stations
IO Link is an industrial communication interface that is independent of any fieldbus and suitable for simple sensors and actuators at the lowest level of industrial control. The IO Link system includes IO Link devices (such as sensors and actuators), IO Link master stations, and cables for standard sensors. The system structure is shown in Figure 1. For example, when a remote IO module compatible with EtherNet/IP serves as the master station, in addition to standard I/O signals, the module sends and receives configuration data, diagnostic data, or enhanced process data through a pulse modulation process, which is then packaged into EtherNet/IP data packets and finally transmitted to the network master station, usually a PLC. In the above applications, the connection between remote I/O and IO Link devices remains the same as that of traditional discrete devices. The advantage of IO Link mainly lies in its greater information exchange capability, which was previously impossible to achieve with standard I/O devices. Another advantage of IO Link is that it does not rely on any fieldbus, and through any I/O module that complies with the IO Link protocol (including local I/O and remote I/O), IO Link sensors or actuators can be integrated into any fieldbus system.
In order to further study the architecture, communication mechanism, and development application of the IO Link system, an IO Link slave toolkit can be designed and developed, including a universal development module for IO Link, an IO Link analysis tool, and an IO Link slave protocol stack. The IO Link universal development module is the foundation for this work and also serves as a bridge between the IO Link master station and equipment signals. The IO Link analysis tool can help developers and testers analyze communication details to identify and solve problems. The IO Link slave protocol stack is a firmware library that provides a hardware abstraction layer and application program interface, allowing developers to easily and quickly develop IO Link slave products on various microprocessor platforms. The IO Link slave station studied in this article only focuses on digital (button) signal input and digital signal output (indicator light). The design of the IO Link universal development module only needs to be expanded on this basis to have the ability to process analog signals.
The IO Link Master module used in this article, USB IO Link Master, can connect IO Link devices to a PC, which can be configured and tested through the IO Link Device Tool software or demonstrated device functionality. IO Link devices must be described through a device description file (IODD file), which includes a set of XML text files and PNG graphic files, which contain information about device identification, communication characteristics, parameters, process data, and diagnostic data. The portion within the elliptical dashed line in Figure 2 is an IO Link three wire cable, with L+/I – being a 24 V DC power supply and C/Q being a signal line used to transmit process data, diagnostic data, configuration data, etc. The IO Link universal development module is mainly composed of data transceivers and microprocessors. It can process input signals from sensors and transmit information to the IO Link master station. It can also receive and process data information from the master station and transmit it to the actuator. The IO Link analysis tool can help developers view, record, analyze data, and understand communication details. This part of the design is not discussed in this article.
Introduction to IO Link Communication Mode4000098-510 TRICONEX controller
IO Link devices can operate in SIO mode (standard I/O mode) or IO Link mode (communication mode). After power on, the device always operates in SIO mode. The port of the main station has different configuration methods. If configured in SIO mode, the main station considers the port as a standard digital input. If configured in communication mode, the main station will automatically identify the communicable devices for communication.
2.1 Data Types4000098-510 TRICONEX controller
The three basic data types for IO Link communication are periodic data (or process data PD), non periodic data (or service data SD), and event.
The process data (PD) of the device is transmitted periodically in the form of a data frame, while service data (SD) is only exchanged after the master station issues a request. Figure 3 shows a typical IO Link message structure. When an event occurs, the “event flag” of the device is set, and the main station reads the reported event (service data cannot be exchanged during the reading process) upon detecting the setting. Therefore, events such as pollution, overheating, short circuits, or device status can be transmitted to the PLC or visualization software through the main station
2.2 Parameter data exchange
Since service data (SD) must be transmitted through PLC requests, SPDU (Service Protocol Data Unit) is defined. In the main station, requests for read and write services are written to SPDU and transmitted to devices through the IO Link interface.
The general structure of SPDU is shown in Figure 4, and its arrangement order is consistent with the transmission order. The elements in SPDU can take different forms depending on the type of service. SPDU allows access to data objects that are intended for transmission, while Index is used to specify the address of the requested data object on the remote IO Link device. In IO Link, there is a term called direct parameter page, which stores parameter information such as minimum cycle time, supplier ID, and master station commands. The data objects accessible in the direct parameter page can be selectively provided through SPDU.
HMT7742 is an IO Link slave transceiver chip that serves as a bridge between the MCU of external sensors or actuators and the 24V signal line that supports IO Link communication. When the IO Link device is connected to the master station, the master station initializes communication and exchanges data with the MCU. HMT7742 serves as the physical layer for communication.
Due to the fact that the three indicator lights (rated voltage 24 V) controlled by the output port of the MCU are powered by the IO Link power cord, it is necessary to monitor the current on the power cord in order to trigger appropriate corrective measures when the current exceeds a set threshold, such as removing the indicator lights from the IO Link power cord. The current monitoring module uses an INA194 current detection amplifier. As a high detection current detector, INA194 is directly connected to the power supply and can detect all downstream faults. It has a very high common mode rejection ratio, as well as a large bandwidth and response speed. It can amplify the voltage on the induction resistor 5O times and output it to the forward input terminal AIN0 of the MCU internal voltage comparator. When the voltage value of AIN0 exceeds the threshold set at the reverse input terminal, By controlling the low level output of PB0, the indicator LAMP can be cut off from the IO Link power line to achieve overcurrent protection function. This part of the circuit is shown in Figure 6.
Application of Data Acquisition IO Module in Thermal Power Plant System4000098-510 TRICONEX controller
The Ethernet IO module is a data acquisition and control device. It uses Ethernet as a communication method to transmit data from various industrial control sensors and actuators to computers or other devices for management and monitoring. As a modern energy supply base, thermal power plants need to widely apply various intelligent control technologies to improve operational efficiency, reduce costs, and improve safety. In this context, the application of barium rhenium Ethernet IO modules is particularly important.
In the application of thermal power plants, the main function of the barium rhenium Ethernet IO module is to achieve real-time monitoring and control of the production process. By connecting to various sensors and actuators, the barium rhenium Ethernet IO module can collect real-time environmental parameters, machine operation status, and other data of the thermal power plant. By analyzing and processing these data, commanders can understand the operation of the thermal power plant and make corresponding adjustments. Compared to traditional automatic control systems, the barium rhenium Ethernet IO module has the advantages of stronger flexibility, faster reaction speed, and higher accuracy, which can greatly improve the operational efficiency and reliability of thermal power plants.
The real-time monitoring and control of thermal power plants require many capabilities of barium rhenium Ethernet IO modules. Here are several common application scenarios:
Firstly, the barium rhenium module can monitor parameters such as gas flow and water flow in thermal power plants. These parameters are crucial for ensuring the normal operation of the thermal power plant. Once these parameters undergo abnormal changes, the DO channel can be connected to the barium rhenium Ethernet IO module, and the alarm signal will immediately sound to remind the command personnel to handle it. Meanwhile, due to the fact that the barium rhenium Ethernet IO module can collect these data in real-time and transmit it to the monitoring system for recording, it can provide better technical support for quality management in thermal power plants.
Secondly, the barium rhenium Ethernet IO module can also monitor the operating status of mechanical equipment in thermal power plants. This includes parameters such as temperature, pressure, vibration, etc. By monitoring and analyzing these parameters, the barium rhenium Ethernet IO module can detect machine equipment faults in a timely manner, thereby avoiding the expansion of losses. In addition, during machine equipment maintenance, historical data recorded by the barium rhenium Ethernet IO module can be used to develop more scientific and reasonable maintenance plans, reduce maintenance costs, and improve maintenance efficiency.
Finally, the barium rhenium Ethernet IO module can also help thermal power plants achieve distributed control. We can remotely control and monitor multiple areas of the thermal power plant by connecting multiple barium rhenium modules to a network. This not only reduces the on-site debugging of equipment, but also strengthens the evaluation of equipment reliability.
In summary, the barium rhenium Ethernet IO module has unique advantages in real-time monitoring and control of thermal power plants. It can help command personnel monitor machine data in real-time, discover abnormal information, take timely measures to avoid impacts, and improve production efficiency and safety.
Remote IO modules based on Ethernet communication are widely used in the field of industrial IoT
With the development of IIOT (Industrial IOT) industrial Internet of Things technology, many traditional assets need to be connected to the internet to achieve unified data collection, analysis, processing, and storage, breaking the traditional phenomenon of device information silos. Therefore, the MQTT Ethernet IO acquisition module M160T, which supports the Internet of Things protocol, is able to unleash its potential by being compatible with existing devices and able to connect to IoT platforms. The MQTT Ethernet IO acquisition module will be widely used in industrial IoT, such as smart property, smart parks, smart factories, smart transportation, smart water conservancy, smart agriculture, smart campuses, smart communities, smart distribution, smart water conservancy, and many other industries.
Ethernet communication technology is a mature communication technology that has been widely applied. Therefore, Ethernet communication is the first choice for enterprises to connect various assets to the Internet of Things platform. Its reasons are stable and reliable, mature technology, fast transmission speed, and fast construction wiring.4000098-510 TRICONEX controller
For traditional various assets, such as low-voltage distribution rooms, air compressor rooms, property and living pump rooms, street light control, liquid level collection, temperature and humidity collection, etc., through the MQTT Ethernet IO collection module, they can be quickly connected to the Internet of Things platform.
So, what characteristics do MQTT Ethernet IO modules need to have when used in IoT solutions? The details are as follows:
1. Actively connect to cloud platforms:
Based on the characteristics of Ethernet communication networking, the Ethernet IO acquisition module must support the TCP Client function, which is not only the TCP client function, so that the Ethernet IO module can actively connect to the IoT platform without the need for complex settings such as peanut shells;
2. Compatible with existing systems:
Support TCP Server and Modbus TCP protocol functions, which can be compatible with traditional upper computer systems or device access of HMI”s TCP client;
3. Access to IoT platforms:
Supports standard MQTT protocol and Modbus TCP protocol, and can be connected to various MQTT protocol IoT platforms such as Huawei Cloud and Alibaba Cloud, or traditional SCADA and DCS systems;
4. Rich IO interfaces and scalability:
There are various types of data to be collected on site, and it is necessary to support the collection of various devices such as 4-20Ma, RS485, DI, DO, etc. At the same time, it is also necessary to have the ability to read RS485 device instrument data or expand the functions of the IO acquisition module;
5. Easy installation method:
The volume of the control box is very limited, so it is necessary to use directly inserted and unplugged wiring terminals, as well as a rail installation method.
6. Industrial grade design
The industrial environment is harsh, and the Ethernet IO module must adopt an industrial grade design to ensure continuous and stable operation in harsh environments.
Through the MQTT Ethernet IO acquisition module, there is no need to replace various existing enterprise assets and the digital transformation of accessing IoT platforms can be quickly achieved. Therefore, the MQTT Ethernet IO acquisition module will be widely used in industrial IoT, such as smart properties, smart parks, smart factories, smart transportation, smart water conservancy, smart agriculture, smart campuses, smart communities, smart power distribution, smart water conservancy, and many other industries.

F9402 HIMA DO digital output
B5232-1 HIMA security module
Bv7050 Germany HIMA
F3313 HIMA security module
HIMA/F35 Digital input module HIMA
F3238 Digital input module HIMA
F3223 HIMA security module
F8628 Digital input module HIMA
F7553 984755302 HIMA DO digital output
Z7128/3331 Germany HIMA
F7533 HIMA security module
F-COM 01 HIMA DO digital output
Bv7045 Germany HIMA
F6216 Germany HIMA
X-AO1601 HIMA DO digital output
F333 HIMA DO digital output
H4116 HIMA security module
F7534 Digital input module HIMA
F3237(Z7108) Digital input module HIMA
F3223 HIMA DO digital output
F-CPU01 Germany HIMA
Bv7044 Digital input module HIMA
Bv7052 HIMA DO digital output
Z7149 Digital input module HIMA
F8650X 984865065 HIMA security module
F7546 Germany HIMA
F-IOP 01 Germany HIMA
F8623B HIMA security module
BT21LE/S HIMA DO digital output
F8560X Digital input module HIMA
F9402 Germany HIMA
F7119 HIMA DO digital output
MC2-440-12TSB-1-1D HIMA security module
F6208 Germany HIMA
F2304 Germany HIMA
F8650X 984865065 HIMA DO digital output
F7531 HIMA security module
HIMA/F35 HIMA DO digital output
F3237(Z7108) Germany HIMA
X-DO1201 985210204 HIMA security module
X-SB01 HIMA security module
H4122 Digital input module HIMA
B4236-1 HIMA DO digital output
F3237 984323702 HIMA DO digital output
K9203A HIMA DO digital output
F6208 HIMA DO digital output
H4135 HIMA DO digital output
F7534 Germany HIMA
Z7128/6217 Germany HIMA
Bv7032 HIMA security module
F6205 Digital input module HIMA
Z7149 Germany HIMA
F7553 984755302 HIMA security module
F-CPU01 Digital input module HIMA
X-CPU 01 HIMA security module
F6217 984621702 Digital input module HIMA
F7536 Germany HIMA
F3224 Digital input module HIMA
F3231 Digital input module HIMA
Z7128/6217 HIMA security module
F8560X HIMA DO digital output
H51q-HS B5233-1 HIMA DO digital output
Z7126 Germany HIMA
F7119 Digital input module HIMA
ES22/E20zd Germany HIMA
F8612B HIMA DO digital output
B4237-1 HIMA security module

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts