4119 Invensys Triconex system
Brand: TRICONEX
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

4119 Invensys Triconex system
4119 Invensys Triconex system
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com
What are the types of integrated IO modules4119 Invensys Triconex system
For a programmable logic controller, IO fulfills the responsibilities of data acquisition and instruction output. What control objectives can a PLC achieve, and the quantity and type of IO are crucial. For general integrated PLCs, the number and types of IO interfaces are constant. Some friends may ask, what if you encounter a complex control project with insufficient IO ports in the PLC? Don”t worry, nowadays PLCs have communication interfaces that can be connected to other IO couplers to achieve IO expansion. So, what are the types of IO modules that we can integrate in our daily lives? Actually, it can be mainly divided into four categories, namely:
1. Digital signal acquisition IO can achieve discontinuous signal acquisition, and a typical IO type is a counter input IO module.
Technology Oasis • Source: Guangcheng CAN Bus • Author: Guangcheng CAN Bus • 2022-05-09 09:52 • 1740 readings
For a programmable logic controller, IO fulfills the responsibilities of data acquisition and instruction output. What control objectives can a PLC achieve, and the quantity and type of IO are crucial. For general integrated PLCs, the number and types of IO interfaces are constant. Some friends may ask, what if you encounter a complex control project with insufficient IO ports in the PLC? Don”t worry, nowadays PLCs have communication interfaces that can be connected to other IO couplers to achieve IO expansion. So, what are the types of IO modules that we can integrate in our daily lives? Actually, it can be mainly divided into four categories, namely:
1. Digital signal acquisition IO can achieve discontinuous signal acquisition, and a typical IO type is a counter input IO module.
2. Digital output IO, which can send out command signals of digital quantities to control actuators, such as PWM IO, can send pulse signals to control servo motors and stepper motors. In addition to PWM IO, we often use relay output type IO.
3. After discussing digital IO, let”s talk about analog IO. Firstly, analog input IO includes voltage analog input IO, current analog input IO, temperature analog input IO, etc. They collect continuous signals.
4. Finally, there is the output type IO of analog quantity, mainly including voltage analog quantity output type IO and current analog quantity output type IO. Some friends may ask why there is no temperature this time, but there are relatively few applications, mainly based on voltage and current types.4119 Invensys Triconex system
Industrial automation solutions, starting with remote IO modules!
The remote IO module is mainly used for collecting analog and digital signals on industrial sites, and can also output analog and digital signals to control equipment. It is possible to expand the input and output ports of data processing equipment such as PLCs and collection instruments. For example, a PLC only has 10 analog input interfaces, but if 30 analog quantities need to be collected on site, remote IO expansion needs to be added.
Furthermore, due to the distance between the equipment and the main control PLC or industrial computer, RS-485 bus is usually used for transmission. There are also some factories with high levels of automation that use industrial Ethernet to control remote IO modules. In the past, when laying lines between equipment and cabinets, people had to connect them one by one, which greatly increased the cost of cables and construction time. Moreover, if the distance was relatively long, they also faced problems such as voltage attenuation. And with the remote IO module, it effectively solves this problem. If your cabinet is 200 meters away from the site and you do not use remote IO, then you need to lay out each signal line for 200 meters. Installing the remote IO module on site can save you a lot of cable costs and reduce the complexity of construction from a cost perspective.
Simply put, sometimes some IO is set up in the on-site device cluster, which can be connected to the PLC through a communication cable to send the signal to any place where it is needed, saving wiring and PLC”s own IO points. Sometimes, the logical “remote” is because the allowed number of “local IO” cannot meet the actual needs, and it needs to be connected to the “remote IO template”, depending on the actual situation.
In addition, the general cabinet room is located on the device site. But some control signals, such as emergency stop and bypass, are implemented in the control room, so remote IO modules need to be used to send these signals to the control system in the cabinet room.
Why use remote I/O?
1. Because in some industrial applications, it is impossible to install PLCs with local I/O modules near on-site equipment due to harsh environments.
2. When you want to place the I/O module near the field device to eliminate long multi-core cables, you can receive signals from distant sensors and send remote control signals to control valves, motors, and other final actuators. The signal can be transmitted at any distance using various transmission protocols such as Ethernet and Profibus through high-speed media such as twisted pair and fiber optic.
3. Multiple transmission protocols such as Ethernet and Profibus can be used to send signals at any distance on high-speed media such as twisted pair and fiber optic.
The barium rhenium technology MXXT remote IO module uses industrial grade components with a wide working voltage of DC9-36V, which can operate normally within the range of -20~70 ℃. It supports RS485/232 communication mode, and the communication protocol adopts standard Modbus TCP protocol, Modbus RTU over TCP protocol, and MQTT protocol. We strive to fully meet the needs of our customers with an electrical and mechanical system that is anti-interference, resistant to harsh environments, and compatible with general use. It has stable performance, reliable quality, short delivery time, and fast response.
Advantages of Barium Rhenium Remote I/O Module
1. It can be controlled by remote commands.
2. Save the cost of using industrial control computers and IO cards, and Ethernet I/O modules can be directly connected to the upper computer system;
3. Replacing 4-20mA signal transmission with 10/100MHz Ethernet transmission has improved transmission speed;
4. Replacing various instrument controller signal lines with an Ethernet cable reduces the attenuation of remote signal transmission;
5. The signal cable of the instrument controller only needs to be connected to the Ethernet I/O module, greatly reducing cable costs and wiring workload.
6. Convenient installation method. Rail installation, high reliability, strong anti-interference ability, and more convenient on-site installation.
Is it better to have a higher number of IO module bit widths?
IO is an important component of PLC, and the collection of PLC information and the output of instructions must be applied to various input and output IO. I don”t know if you have read some IO user manuals. One of their instructions is the device”s bit width, such as 12 bits and 16 bits. So, is it better to have a higher number of bit widths for the IO module? Let”s talk about this matter.
Bit width is the number of bits of data that can be transmitted within a clock cycle, and the larger the number of bits, the greater the amount of data that can be transmitted instantly. From this perspective, the larger the bit width of the IO module, the better. This is not a problem. However, the amount of data transmission, also known as data bandwidth, depends not only on the bit width, but also on the frequency of data transmission. The multiplication of the two is the final total amount of data transmitted. That is to say, even if the light position is wide, but the frequency is too high, it still cannot work. At the same time, the larger the bit width, the higher the hardware cost, and the greater the heat generation and power consumption of the device.
How to Apply Ethernet IO Module to Weighbridge Data Collection4119 Invensys Triconex system
Weighbridge, a large scale set on the ground, usually used to weigh the tonnage of cargo carried by a truck. It is the main weighing equipment used for measuring bulk goods in factories, mines, merchants, etc. The MXXXX series of Ethernet IO modules with barium rhenium technology have rich IO ports that can be used to assist in data collection and transmission of the weighbridge, quickly achieving comprehensive management of data and control.
Before the vehicle enters the weighbridge, there will be an infrared sensor scanning about a few hundred meters. The infrared sensor will output a switch signal to the Ethernet IO module, indicating that a vehicle needs to enter. Before the vehicle officially enters the weighbridge for weighing, there will be an infrared barrier sensor scanning, and the barrier will also output a switch signal to the Ethernet IO module. When the vehicle is completely parked in front of the weighbridge (including whether the position is correct), the central control room will decide whether to start weighing based on the information received by the IO module from the radar sensor. Finally, the vehicle is weighed and drives away from the weighbridge. The scanning signal from the infrared barrier sensor at the exit is transmitted to the IO module, and the central control room controls the IO port of the IO module to open (close) the barrier. The green light will light up, and the vehicle will fully exit and leave the weighing weighbridge. The entire weighing process requires only one Ethernet IO module to collect information and control actions.4119 Invensys Triconex system
The MxxxT industrial remote Ethernet I/O data acquisition module adopts an industrial grade circuit design. The digital input adopts optocoupler isolation, providing 12 pulse counting inputs, supporting dry and wet contact input types. The analog input adopts operational amplifier isolation, supporting 12 bit high-precision data acquisition, compatible with 0~5V, 0~10V, 0~20mA, and 4~20mA input types. The DO output is a transistor Sink output, providing one channel of high-speed pulse output, The thermal resistance RTD input supports two types: PT100 and PT1000, and the analog AO output supports 0-10VDC output.
Pocket Io ™ The development platform has opened up numerous new avenues for experiencing the full power of Industry 4.0.
Compact design: compact structure, ultra small size, and overall dimensions (10 cubic inches: 3.5 “x 3.5” x 0.8 “).
Reliable and safe technology: Composed of advanced industrial products, all products have a rated working environment temperature of -40 ° C to+125 ° C, fully utilizing Maxim”s reliable, safe, and fast demagnetization technology.
Efficient: Ensure low power consumption and improve efficiency – no need for cooling fans.
Integrate numerous powerful interfaces: provide a complete set of 30 IOs for controlling the entire manufacturing node or a certain device, including: 4 analog inputs, 1 analog output, 8 digital inputs, 8 digital outputs, 2 RS-485 (compatible with Profibus fieldbus), 3 encoder/electrical control ports, and 4 IO Link hosts.
Long battery life: Firstly, the compact and portable PLC platform can work for up to 2 hours using “AA/AAA” type batteries, and 8 hours using LiFePO4 rechargeable batteries.
Programmable: It can be programmed through Arduino Sketch or using Intel”s Edison Eclipse IDE tool, supporting Windows, Linux, or Mac OS operating systems.
Easy to use: Sketches can be converted into apps and then downloaded to iPads ® Or iPhone ®  (Converted to an HMI panel for controlling Pocket IO).
What are the advantages of Ethernet remote IO modules that can be cascaded?
Advantages and specific application scenarios of Ethernet remote IO modules that can be cascaded
For scenarios where data collection control points are linearly distributed, such as streetlights, bridges, streetlights, digital factories, parking lot parking monitoring, smart parking lots, smart parking racks, and building automation control systems in smart parks, using cascading dual Ethernet remote IO modules saves more costs than using single Ethernet remote IO modules.
The Ethernet remote IO module that can be cascaded is a new type of Ethernet remote IO module that supports MAC layer data exchange and can achieve hand in hand connection. This not only saves switch interfaces, but also reduces a large amount of Ethernet cable costs, wiring space, and wiring costs.
Its advantages are as follows:
1. No need for a large number of Ethernet switches or occupying Ethernet switch ports;
2. It can save a lot of Ethernet cables, cable space, and labor costs for installing cables;
3. The overall cost has significantly decreased;
4. Supports both Modbus RTU protocol, Modbus TCP protocol, and the Internet of Things protocol MQTT protocol;
5. Support TCP Server and TCP Client services;
6. Can be connected to SCADA systems, PLC systems, or cloud platforms;
7. The series uses a MAC layer for data exchange, ensuring that network connectivity does not cause communication issues with subsequent devices due to device failures in the middle.
The comparison between cascaded Ethernet remote IO modules and traditional IO modules used in building automation systems is shown in the following figure:
1. Adopting a cascaded dual Ethernet remote IO module, data acquisition and control wiring for floors with a height of 70 meters only requires a 70 meter Ethernet cable;
2. Using a traditional single Ethernet remote IO module, the data acquisition and control system wiring for a 70 meter high floor requires a 280 meter Ethernet cable.
It can be seen that using cascaded dual Ethernet remote IO modules can save a lot of wiring costs compared to traditional single Ethernet remote IO modules.
MQTT IoT Remote IO Module Based on Ethernet Communication Technology
MQTT IoT Remote IO Module Based on Ethernet Communication Technology
Barium rhenium technology remote IO modules are widely used in IoT scenarios such as intelligent transportation, smart water conservancy, smart agriculture, smart campuses, smart communities, smart power distribution, and smart water conservancy.
With the development of IIOT industrial Internet of Things technology, more and more traditional assets need to be connected to the internet, achieving unified data collection and analysis, and breaking the phenomenon of traditional device information silos. The barium rhenium technology remote IO module M160T, which supports IoT protocols, has become an excellent choice for many enterprises to achieve device networking, remote control, and data collection based on the compatibility of existing devices and the accessibility of IoT platforms!
Ethernet communication technology is a mature communication technology because it has the characteristics of stability, reliability, mature technology, fast transmission speed, and fast construction wiring. Due to its wide application, Ethernet communication through the MQTT protocol is the main way for enterprise equipment to go to the cloud. Barium rhenium technology can quickly collect data and control such as air compressor room, property living pump room, street light control, liquid level collection, temperature and humidity collection through Ethernet remote IO module.4119 Invensys Triconex system
So, why is the remote IO module of barium rhenium technology widely used in the field of industrial IoT? The specific reasons are as follows.
1. Actively connect to cloud platforms:
Based on the characteristics of Ethernet communication networks, the barium rhenium technology remote IO module does not require complex settings such as peanut shells to achieve the Internet of Things. The barium rhenium technology remote IO module needs to support both TCP client and TCP server functions.
2. Compatibility with existing systems:
It supports TCP Server and Modbus TCP protocol functions, and is compatible with device access of traditional upper level systems or HMI TCP clients.
3. Support multiple IoT platforms:
Supports standard MQTT, Modbus TCP, and Modbus RTU over TCP protocols. It can be connected to public cloud IoT platforms and user built MQTT private clouds through the MQTT protocol. It can also be connected to SCADA and DCS systems through Modbus TCP.
4. Rich IO interfaces and scalability:
There are many types of IO for industrial field data collection and replication. The Ethernet IO module of barium rhenium technology supports signal acquisition from various devices such as 4-20Ma, 0-20mA, 0-5V, 0-10V, RS485, DI, DO, PT100, PT1000, pulse input, pulse output, etc. At the same time, it expands the instrument data reading ability of RS485 devices.
5. Convenient installation method:
The volume of industrial on-site control boxes is often very limited, and the barium rhenium technology Ethernet IO module adopts a direct plug-in connection terminal and rail installation method. The compact volume greatly saves space in the control box!
6. Industrial grade design
The industrial environment is harsh, and the remote IO module using barium rhenium technology needs to adopt an industrial grade design, which can work continuously and stably in harsh environments.
Through the use of barium rhenium technology remote IO modules, there is no need to replace existing various enterprise assets, and the digital transition to the Internet of Things platform can be quickly achieved. Therefore, barium rhenium technology remote IO modules are widely used in industrial IoT, such as intelligent real estate, intelligent campus, intelligent factory, intelligent transportation, intelligent water conservancy, intelligent agriculture, intelligent campus, intelligent community, intelligent transportation, and many other industries.
What is the role of distributed IO modules and what are their main applications in
The distributed IO module transmits status signals from the measurement and control field to various measurement and control fields for control. It is mainly used in the industrial field and can also be used for detection of equipment such as air conditioners and motors.
In distributed systems, there are important business data closely related to system operation, as well as data related to nodes, application services, and data services, which are crucial for the normal operation of clusters.
IO on general PLCs is usually closely followed by CPU units, but in order to facilitate connection and maintenance, the concept of distributed IO has been proposed in the industrial field. That is to say, the IO unit can be arranged far away from the PLC CPU unit and communicate through the network communication protocol of the device layer.
The distributed IO module is developed for detecting and implementing remote control of various types of standard analog and switch signals (frequency, pulse, or switch state signals) in the field of measurement and control. The series of modules can digitize the test signal front-end and transmit it to the host through optical fiber; Or transmit the control instructions sent by the host to the controlled device to achieve remote control. Especially suitable for state detection and control of complex electromagnetic environments in power, industrial control, on-site switchgear, and large power equipment.
The role of distributed IO modules:
1. Support 4-way switch digital quantity
2. Supports 8 analog inputs
3. 4 relay outputs, 1 RS485 serial port data acquisition to Ethernet
4. 485 to Ethernet serial server
5. Supports Modbus to TCP/UDP protocol conversion
6. Supports virtual serial ports and interfaces with various configuration software
7. Support 0-5V, 0-10V, 0-30V range acquisition
8. Supports 0-20ma and 4-20ma range acquisition
Application Scheme of Industrial Ethernet Remote IO Module in Intelligent Manufacturing Workshop
With the advent of Industry 4.0, intelligent manufacturing has become a trend in industrial production. Intelligent manufacturing requires efficient, stable, and reliable industrial Ethernet remote IO modules to monitor the production process. This article will share an application case of an intelligent manufacturing workshop based on industrial Ethernet remote IO module.4119 Invensys Triconex system
The production process of this intelligent manufacturing workshop is mainly divided into two parts: injection molding and automated assembly. The injection molding process requires controlling parameters such as the melting temperature of the melt, the speed and pressure of the injection molding machine. The automated assembly process requires controlling the actions of the assembly robot and detecting the quality of the product. In addition to these production process data, there are also equipment production data such as daily and weekly production in the workshop, as well as equipment status data such as operation, manual, automatic, mold adjustment, and alarm.
In the past, the production process of the factory mainly relied on traditional hard wiring to control the production process, resulting in low work efficiency due to the need for frequent replacement of transmission lines to meet production needs. Moreover, it is very difficult to collect a large number of types of detection and monitoring data for intelligent manufacturing. In order to improve efficiency, production quality, and reliability, the factory has introduced the industrial Ethernet remote IO module MxxT using barium rhenium technology.
The injection molding machine itself comes with MODBUS industrial control bus data or basic status signal output. The barium rhenium technology remote IO module collects data from the device interface RS232/RS485 port, collects status information of the injection molding machine such as startup, operation, and pause, and uploads it to the injection molding machine controller, or wirelessly uploads it to the cloud server. Based on devices, according to the communication protocols and interfaces of different devices, data is obtained by calling their interface channels, and then transmitted to the server.
The remote IO module is connected to the controller of the injection molding machine, and the operation data of the injection molding machine is uploaded and distributed wirelessly, achieving remote monitoring and intelligent control of the injection molding machine. In addition, the remote I/O module supports perceptual access to peripheral devices such as mold temperature machines, cutting machines, and dryers for injection molding machines, providing users with smart factory services.
During the injection molding process, the industrial Ethernet remote IO module transmits real-4119 Invensys Triconex systemtime data such as temperature, pressure, and speed to the main controller for monitoring and adjustment, ensuring the stability and compliance of production parameters under different conditions. In the automated assembly process, the industrial Ethernet remote IO module collects data through sensors and other devices, and transmits the relevant data to the main controller for adjustment of relevant actions. For example, the industrial Ethernet remote IO module can monitor the actions of assembly robots, detect the accuracy of product assembly and product quality, and ensure the production quality and stability of the product. At the same time, all production data can also be collected and analyzed remotely, helping enterprise managers better monitor production efficiency and quality.
By introducing industrial Ethernet remote IO modules, this intelligent manufacturing workshop not only improves production efficiency and stability, but also reduces labor and energy costs. Because the industrial Ethernet remote IO module can help enterprises complete the collection and monitoring of production data with one click, as well as avoid unnecessary line replacement and the need for workers to enter and exit the production process, thereby reducing costs and improving production efficiency for enterprises.
In summary, the application of industrial Ethernet remote IO modules in intelligent manufacturing workshops not only improves production efficiency and quality, reduces costs, but also achieves intelligent and digital management of production processes, bringing more opportunities and development space for enterprise development.
In addition, this device is widely used for networking and data collection of industrial equipment such as injection molding machines, air compressors, CNC machine tools, on-site PLCs, instruments, sensors, CNC, and electromechanical equipment.
Building a High Channel Density Digital IO Module for the Next Generation Industrial Automation Controller
There are currently many articles introducing Industry 4.0, and smart sensors are becoming increasingly popular in factory environments (I and other authors have written about these topics). Although we have all noticed a significant increase in the use of sensors in factories, processing plants, and even some newly built automation systems, the widespread use of sensors has also brought about an important change, which is the need to handle a large amount of IO within these old controllers. These IOs may be digital or analog. This requires the construction of high-density IO modules with size and heat limitations. In this article, I will focus on digital IO, and in subsequent articles, I will introduce analog IO.
Usually, digital IO in PLC consists of discrete devices such as resistors/capacitors or independent FET drives. In order to minimize the size of the controller as much as possible and to handle 2 to 4 times the number of channels, this has led to a shift from a separate approach to an integrated approach.
We can use the entire article to illustrate the drawbacks of the split method, especially when the number of channels processed by each module reaches 8 or more. However, when it comes to high heat/power consumption, a large number of split components (from the perspective of size and mean time between failures (MTBF)), and the need for reliable system specifications, it is sufficient to demonstrate that the split method is not feasible.
Figure 1 shows the technical challenges faced in building high-density digital input (DI) and digital output (DO) modules. In both Di and DO systems, size and heat dissipation issues need to be considered.
Digital input
size
heat
Supports all input types
Type 1, 2, 3, Input
Supports 24 V and 48 V inputs
Robust operating specifications
Wire breakage detection
Digital output
Support for different types of output driver configurations
size
Integrated demagnetization of inductive loads
Heat – When driving multiple outputs
Drive accuracy
diagnosis
For digital input, it is also important to note that it supports different input types, including 1/2/3 type inputs, and in some cases, 24V and 48V inputs. In all cases, reliable operating characteristics are crucial, and sometimes circuit detection is also crucial.
For digital outputs, the system uses different FET configurations to drive the load. The accuracy of the driving current is usually an important consideration. In many cases, diagnosis is also very important.
We will explore how integrated solutions can help address some of these challenges.
Design a High Channel Density Digital Input Module
The traditional split design uses a resistive voltage divider network to convert 24V/48V signals into signals that can be used by microcontrollers. The front-end can also use discrete RC filters. If isolation is required, external optocouplers are sometimes used.
Figure 1 shows a typical discrete method for constructing digital input circuits.
Figure 1. Considerations for digital input and output modules.
This type of design is suitable for a certain number of digital inputs; 4 to 8 per board. Beyond this number, this design will soon become impractical. This separation scheme can bring various problems, including:
High power consumption and related board high temperature points.
Each channel requires an optocoupler.
Excessive components can lead to low FIT rate and even require larger devices.
More importantly, the split design method means that the input current increases linearly with the input voltage. Assuming a 2.2K Ω input resistor and 24V V is used. When the input is 1, for example, at 24V, the input current is 11mA, which is equivalent to a power consumption of 264mW. The power consumption of the 8-channel module is greater than 2W, and the power consumption of the 32-bit module is greater than 8W. Refer to Figure 3 below
From a cooling perspective alone, this split design cannot support multiple channels on a single board.
One of the biggest advantages of integrated digital input design is the significant reduction in power consumption, thereby reducing heat dissipation. Most integrated digital input devices allow configurable input current limitations to significantly reduce power consumption.
When the current limiting value is set to 2.6mA, the power consumption is significantly reduced, with each channel approximately 60mW. The rated value of the 8-channel digital input module can now be set below 0.5
Another reason for opposing the use of split logic design is that sometimes DI modules must support different types of inputs. The standard 24V digital input specifications published by IEC are divided into Type 1, Type 2, and Type 3. Type 1 and Type 3 are usually used in combination because their current and threshold limits are very similar. Type 2 has a current limit of 6mA, which is higher. When using the split method, it may be necessary to redesign as most discrete values need to be updated.
However, integrated digital input products typically support all three types. Essentially, Type 1 and Type 3 are generally supported by integrated digital input devices. However, in order to meet the minimum current requirement of 6mA for Type 2 input, we need to use two channels in parallel for one field input. And only adjust the current limiting resistance. This requires a circuit board change, but the change is minimal.
Safety Instrumented System (SIS) is a4119 Invensys Triconex system safety system used to monitor and control production processes, and is a system that prevents catastrophic accidents from occurring. SIS is usually composed of sensors, logic solvers, and actuators, which can monitor and control various industrial production processes, including petrochemical, power, metallurgy, pharmaceuticals, pulp, and paper industries. The main function of SIS is to ensure the safety and reliability of industrial processes to prevent accidents from occurring. It can determine whether there are potential hazards or accident risks by monitoring the status of equipment, process parameters, and environmental factors, and take appropriate measures in a timely manner to prevent accidents from occurring. SIS can also be integrated with other control systems such as DCS or PLC to achieve more efficient production process monitoring and management.4119 Invensys Triconex system
Invensys is an industrial software and control systems company headquartered in the UK, established in 1987. The company provides a range of solutions, including process automation, factory automation, energy management, railway transportation, aerospace, defense, and automotive fields. Invensys has over 30000 employees worldwide and customers worldwide. In 2019, Invensys was acquired by Schneider Electric of France.
Connex is a provider of industrial automation and information solutions headquartered in the United States, established in 2000. The company mainly provides data collection, monitoring, and visualization solutions, as well as industrial network and communication solutions. Kangjisen has over 2000 employees worldwide and customers worldwide. In China, Kangjisen is fully responsible by Beijing Kangjisen Huagen Technology Co., Ltd., providing sales, technical support, engineering, training, and a series of engineering and technical services.
The MXXE series remote IO module is designed at an industrial level, suitable for industrial IoT and automation control systems. The MXXE industrial Ethernet remote I/O is equipped with two Ethernet ports for MAC layer data exchange chips, allowing data to flow down from the expandable daisy chain Ethernet remote I/O array to another local Ethernet device or up to the server.
Factory automation, security, and monitoring systems, as well as tunnel communication applications, can utilize daisy chain Ethernet to build multi-point I/O networks through standard Ethernet cables. Many industrial automation users are familiar with the most commonly used multipoint configurations in fieldbus solutions. The daisy chain function of MxxXE remote I/O not only improves the scalability and installation possibility of remote I/O applications, but also reduces the overall cost by reducing the need for individual Ethernet switches. This daisy chain equipment installation method will also reduce overall labor and wiring costs.
The difference between Ethernet remote IO module and industrial computer IO board card
The application of Ethernet remote IO module is very extensive, mainly used for distributed data collection and control, especially suitable for situations where data points are scattered and control points are scattered.
The traditional approach is to connect various instrument signals directly to the IO card through cables using an industrial computer and an IO board card. This method has high wiring costs and high signal attenuation.
The Ethernet remote IO module can directly connect the IO module to the PLC or industrial control computer, and connect the IO to the PLC or industrial control computer through an Ethernet cable. Various instrument controller signals can be directly connected to the Ethernet IO module nearby, which has several advantages:
1. It saves industrial control computers and IO boards, and Ethernet IO modules can be directly connected to the upper computer system;
2. Replacing 4-20mA signal transmission with 10/100MHz Ethernet transmission has improved transmission speed;
3. Replacing various instrument controller signal lines with an Ethernet cable reduces the attenuation of remote signal transmission;
4. The signal cable of the instrument controller only needs to be connected to the Ethernet IO module, greatly reducing cable costs and wiring workload;
5. The M160T series Ethernet remote IO module can also be directly transmitted to the Internet of Things platform through MQTT for remote monitoring.
The profinet to Modubs distributed remote IO module has now been applied in many fields, and Huajie Intelligent Control has implemented profinet remote IO modules that support Siemens 200smart, 3001200, and 1500.
Huajie Intelligent Control distributed IO supports Modubs 16D 16DO 32DI 32 DO, with flexible on-site installation, which can be installed nearby with sensors and actuators, saving wiring and PLC”s own IO points. Provides high-speed data transmission, enabling reliable communication between the controller CPU and I/O system
The advantage of using profinet distributed remote IO module in profinet is that the wiring is simple, only one network cable is needed, and each point is collected and controlled through the remote IO module. The program is controlled by Siemens 1200 or 1500, which not only reduces wiring work but also reduces wire costs
Huajie Intelligent Control has good compatibility with distributed IO and has expanded other bus based distributed IO systems, which can also help you more rationalize the management of your distributed remote devices and achieve unlimited expansion. The supporting software can assist with configuration, debugging, and diagnosis of your system. There are multiple series of models available, including HJ3204 to HJ3209, with stable performance and affordable prices, Provide maximum convenience for enterprise engineering.

PCI-6033E
PCI-6032E
PCI-6031E
PCI-6030E
PCI-6025E
PCI-6024E
PCI-6023E
PCI-6011E
PCI-5922
PCI-5911
PCI-5640R
PCI-5640
PCI-5154
PCI-5153EX
PCI-5153
PCI-5152
PCI-5142
PCI-5124
PCI-5122EX
PCI-5122
PCI-5114
PCI-5112
PCI-5105
PCI-5102
PCI-4552
PCI-4551
PCI-4474
PCI-4472B
PCI-4472
PCI-4462
PCI-4461
PCI-4454
PCI-4452
PCI-4451
PCI-4070
PCI-4021
NI-9917
NI-9683
NI-9505
NI-9260 NI
ni-9250
NI-9234
Ni-9227
NI-9208
NI-9159
NI-9157
NI-9155
NI-9154
NI-9151
NI-9149
NI-9148
NI-9147
NI-9146
NI-9145
NI-9144
NI-5741
NI-5191
PXIE-2529
PXI-2520
USB-6525
PXIE-8840QC
PXIE-8840
PXIE-8135
PXIE-4081
pxie-4080
PXI-8461
PXI-6713
PXI-6683
PXI-6602
PXI-5402
PXI-2564
PXI-2510
PCIE-6321
NI-9216
GPIB-140A/2
FP-TB-1
CFP-DO-403
CFP-DO-400
CFP-DI-304
CFP-CB-1
CFP-AO-210
CFP-AO-200
CFP-AI-111
CFP-AI-100
CFP-1808
CFP-1804
AT-5102

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts