Sale!

DS200TCCBG3B Gas turbine system

¥666.00

DS200TCCBG3B Gas turbine system
Brand: General Electric
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

DS200TCCBG3B Gas turbine system
DS200TCCBG3B Gas turbine system
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com

Phenomenon of generator leading phase operation_ Hazards of generator leading phase operation
Reduce the generator excitation current, reduce the generator potential, and the power factor angle will become advanced. The generator load current will generate the magnetic armature reaction. The generator will transmit active power to the system, but absorb reactive power. This operation state is called leading phase operation.
Phenomenon of generator leading phase operation
1. The excitation current is greatly reduced;
2. Generator stator voltage decreases;
3. The reactive load of the generator becomes negative.
Hazards of generator leading phase operation
1. Increasing the active load of the generator will make the generator develop in an unstable direction, which is easy to cause unstable operation of the generator and even system oscillation accidents.DS200TCCBG3B Gas turbine system
2. Continue to reduce the excitation current of the generator and increase the depth of the generator leading phase, which may cause the generator loss of excitation protection action or the generator unstable operation.
3. When the generator is in phase leading operation, the stator current increases and the stator heating increases. The change ratio of the leakage flux at the end of the stator increases, making the end heating the most serious, and the temperature of the generator stator coil will continue to rise.
4. When the generator is in phase leading operation, the generator outlet voltage is reduced, resulting in the reduction of 6KV bus voltage. The high-voltage motor with low-voltage protection will trip. The electrical equipment in operation will heat up due to the reduction of bus voltage and the increase of current, and the insulation of the equipment will be damaged if it is operated for a long time.
When the generator is in leading phase operation. The magnetic leakage at the end of the stator increases when it is operated in a later phase. In particular, the line load of large generators is high, and the end magnetic leakage is relatively large during normal operation. The end core pressure refers to the temperature rise of the connecting piece. During the leading phase operation, the temperature rise is aggravated due to the increase of magnetic leakage. Therefore, when the generator terminal voltage is reduced during leading phase operation, the auxiliary power voltage is also reduced accordingly. If it exceeds 10%, the auxiliary power operation will be affected.
Therefore, the leading phase operation depth of synchronous generator shall be determined by test, that is, how much reactive power can be absorbed to maintain the static stability and transient stability of the system under a certain active power supply state, and the temperature rise of each component shall not exceed the limit, and can meet the voltage requirements.
When the inductive reactive power supplied by the system is more than required, the system voltage will rise, and the generator is required to generate less reactive power or even absorb reactive power. At this time, the generator can change from delayed phase operation to leading phase operation.
Precautions for leading phase operation of generator
1. Check that the generator excitation regulator should operate in automatic mode, and the low excitation limit function of the generator excitation regulator and the generator excitation loss protection should be put into operation normally. Check that the speed control system is flexible and free of jamming.
2. The leading phase depth of the generator shall be adjusted according to the command of the shift supervisor. If the generator automatically leads to phase due to high voltage on the network, the monitoring of all parameters of the generator shall be strengthened, and the report shall be reported to the superior in time.
3. When increasing or decreasing the excitation of the generator, the speed should be slow, and it is not allowed to adjust rapidly and greatly. The limit value of the leading phase operation should be controlled within the specified range, and it should always be less than the limit action value of the low excitation.
4. When lowering the excitation of the generator, if the low excitation limiter acts, immediately stop lowering the excitation of the generator, and properly increase the excitation of the generator to ensure that all parameters of the generator are within the normal range.
5. Pay attention to monitor the static stability of the generator. The indication of each meter of the generator is normal and there is no oscillation. Check that the sound of the generator is normal to prevent the generator from out of step or oscillation.
6. The temperature rise at the end of the stator core of the generator shall be closely monitored to prevent overheating of the generator. The temperature at the end of the core shall not exceed 120 ℃ and the temperature of the copper shield shall not exceed 120 ℃.
7. In case of obvious swing of active and reactive power of other operating units, the excitation current of the leading phase generator shall be increased immediately, and the shift supervisor shall be reported at the same time to recover the delayed phase operation of the generator.
8. If the 6kV main auxiliary equipment fails or needs to be switched, apply to the middle note to stop the generator in leading phase operation, restore the late phase operation state of the generator, and prevent the 6kV and 400V auxiliary voltage from being too low, protection action or tripping of some 400V equipment due to the large reactive load absorbed by the equipment during startup and shutdown.
9. In case of equipment failure, when it is necessary to reduce the load and eliminate defects, immediately apply for middle note to stop leading phase operation, and then apply for leading phase operation after the standby group resumes normal operation.

 

ABB 3BSE008508R2 (AC800F模块) 工控系统自动化备件
ABB PP800面板 PP815A 3BSE042239R2触摸屏
ABB CI851 模块 (ABB S800 通讯卡)
ABB IGCT 5SGX1060H0003 可控硅 5SHY系列可控硅都有货
ABB 57360001-A 备件板 工控系统自动化备件
ABB PM510V16 模块
ABB PP846 模块 控制器
ABB AO801 模块 (ABB S800 通讯卡)
Bently Nevada本特利 146031-01 模块卡件
ABB 3BSE010796R1 (AC800F模块) 工控系统自动化备件
ABB APMXB03 E-32215 模块 (ABB S800 通讯卡)
ABB 3BSE018295R1 (AC800F模块) 工控系统自动化备件
ABB AO845A-eA 模块 (ABB S800 通讯卡)
ABB PU410 模块 控制器
ABB AI801 3BSE020512R1 模块 (ABB S800 通讯卡)
ABB CI630K02 模块 (ABB S800 通讯卡)
Bently Nevada本特利 3500/40-01-00 BENTLY 模块卡件
ABB PM564-T 模块 控制器
ABB 3BHE039203R0101 (AC800F模块) 工控系统自动化备件
ABB 3BSE008572R1 TU847 (AC800F模块) 工控系统自动化备件
ABB 3BSE084741R1 (AC800F模块) 工控系统自动化备件
ABB PPC380AE102 模块 控制器
ABB AI523 模块 (ABB S800 通讯卡)
ABB 57360001-DC DSMC120 备件板 工控系统自动化备件
ABB 3HNA023093-001 (AC800F模块) 工控系统自动化备件
Bently Nevada本特利 3500/91 模块卡件
Bently Nevada本特利 129966-03 模块卡件
Bently Nevada本特利 176449-04 模块卡件
ABB PM1533BSE003644R1 模块 控制器
ABB 3BSE008546R1 AO820 (AC800F模块) 工控系统自动化备件
ABB PM851AK01-eA 模块 控制器
ABB PM856 模块
本特利Bently Nevada 模块 3500/93 135785-01
ABB CI855 模块 (ABB S800 通讯卡)
ABB 3BSE022360R1 (AC800F模块) 工控系统自动化备件
ABB 086318-501 板子 进口工控备件
ABB AI810-eA 3BSE008516R2 模块 (ABB S800 通讯卡)
ABB DAI05 模块 (ABB S800 通讯卡)
Bently Nevada本特利 133819-02 模块卡件
ABB CI773F 模块 (ABB S800 通讯卡)
ABB CI854K01 3BSE025961R1 模块 (ABB S800 通讯卡)
Bently Nevada本特利 140734-02 模块卡件
ABB CI560 模块 (ABB S800 通讯卡)
ABB 3BHE023681R0103 (AC800F模块) 工控系统自动化备件
ABB IGCT 88FN02B-E 可控硅 5SHY系列可控硅都有货
ABB PPD103-B03-10-150000 模块 控制器
ABB PP825A 模块 控制器
ABB PMC-6130-J 模块 控制器
ABB 3BSE042236R1 模块
GE General Electric DS200CPCAG1ABB 燃机卡 IN STOCK
ABB 07EA90-SI 控制器模块PLC风电设备
ABB CI546 3BSE012545R1 模块 (ABB S800 通讯卡)
ABB IGCT 5SHX1060H0001 可控硅 5SHY系列可控硅都有货
ABB 3BSE036634R1 (AC800F模块) 工控系统自动化备件
ABB AO895 3BSC690087R1 模块 (ABB S800 通讯卡)
ABB PM866AK01 模块 控制器
ABB PM825-1 模块 控制器
ABB PP865A 模块 控制器
Bently Nevada本特利 163179-01 模块卡件
ABB 3BSE018681R1 (AC800F模块) 工控系统自动化备件
ABB 3BSE008516R2 AI810 (AC800F模块) 工控系统自动化备件
Bently Nevada本特利 3500/25-01-02-00 模块卡件
ABB PP860 触摸屏 PP800面板
ABB CI531 模块 (ABB S800 通讯卡)
ABB 086444-005 板子 进口工控备件
ABB CI545V01 模块 (ABB S800 通讯卡)
ABB IGCT 5SHY4045L0004 可控硅 5SHY系列可控硅都有货
ABB 3BHE014105R0001 (AC800F模块) 工控系统自动化备件
ABB AI845 模块 (ABB S800 通讯卡)
ABB 3BSE030221R1 (AC800F模块) 工控系统自动化备件
ABB 57350001-CU DSAV111 备件板 工控系统自动化备件
ABB IGCT 5SHX1960L0004 可控硅 5SHY系列可控硅都有货
Bently Nevada本特利 125840-01 模块卡件

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts