Excitation system DSQC302

¥666.00

Excitation system DSQC302
Brand: General Electric
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

Excitation system DSQC302
Excitation system DSQC302
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com

1、 Why can”t I exceed the speed limit?
1) During the operation of the steam turbine, the centrifugal force on the blade is proportional to the square of the rotating speed, that is to say, although the rotating speed increases slightly, the centrifugal force on the rotor increases geometrically, which is taken into account when the steam turbine is designed, so the overspeed phenomenon is extremely dangerous to the steam turbine.
2) During the design and manufacturing process, the rotor of the rotating machine will have its own self-vibration frequency, which is the frequency corresponding to the critical speed that we should pay attention to when we rush. Therefore, the normal working speed of steam turbine is not within the range of critical speed. However, when the turbine speed exceeds the working speed and reaches twice the frequency of the rotor itself, the vibration of the unit will greatly increase, even greater than the vibration of the unit over the critical speed. Because of the friction between the dynamic and static parts caused by the large vibration of the unit, the vibration of the unit will continue to increase, which leads to a vicious cycle. In serious cases, the steam turbine will be completely scrapped.
3) If the unit is used for power generation, since the grid frequency in China is set at 50Hz, the corresponding turbine speed should also be 3000rpm. If the unit does not work at the rated speed, it will not be able to operate in parallel with the grid. Even in the isolated network operation, if the frequency increases, it will directly lead to the corresponding increase in the rotating speed of the rotating machinery, which will damage the normal operation of the motor, cause the abnormal increase in the output of the pump or fan, make the motor heat, increase the vibration of the pump or fan, and easily lead to the burning accident. At the same time, it will affect the normal operation of the filter and reduce the power quality.
2、 Main causes of turbine overspeed
The overspeed accident of steam turbine is caused by the fault of the speed regulation and protection system of the steam turbine and its own defects, but it is often directly related to the operation and maintenance. It is analyzed and discussed according to different accident causes and fault links.
1. The speed control system has defects:
The task of the turbine speed control system is not only to ensure the normal operation of the turbine at the rated speed, but also to ensure that the speed rise does not exceed the specified allowable value after the turbine load rejection, so the speed control system is the first measure to prevent the turbine overspeed. If the turbine cannot maintain no-load operation after shedding the load, it may cause overspeed. There are several reasons for excessive speed rise after load rejection of steam turbine.
(1) The governing valve cannot be closed or the steam leakage is large.
(2) The extraction check valve is not tight or refuses to act.
(3) The sluggish rate of the speed control system is too large or the regulating parts are jammed.
(4) The operation mode is unreasonable or improperly adjusted.
(5) The unequal rate of speed regulation system is too large.
(6) Improper dynamic characteristics of speed control system.Excitation system DSQC302
(7) Improper setting of the speed control system, such as the adjustment range of the synchronizer and the expansion clearance of the steam distribution mechanism do not meet the requirements.
2. Turbine overspeed protection system fault:
(1) The emergency governor does not operate or the operating speed is too high
The operating speed of the emergency governor is generally 10-12% higher than the rated speed, which is the main protection equipment to protect the steam turbine from excessive increase in speed. In addition, different units have not specified additional protection or electric overspeed device with operating speed slightly higher than the emergency governor. If the emergency governor does not act or acts excessively when the turbine speed rises, the main reasons are:
① The heavy hammer or flying ring guide rod is jammed.
② The dynamic and static parts of the heavy hammer or flying ring are not concentric, and they hold their strength during operation. ③ The spring produces excessive radial deformation under the force, resulting in friction with the hole wall.
④ The gap between the kissing buckle or the striking plate is too large, and the impact can not make the slide valve of the emergency governor act after the impact is flying out.
(2) The slide valve of the emergency governor is jammed and cannot operate.
(3) The automatic main throttle valve and governor valve are jammed.

 

GE IC697CMM711Q
GE IC697CHS791
GE IC697CHS790
GE IC697CHS783
GE IC697CHS782
GE IC697CHS770
GE IC697CHS750
GE IC697BEM731Z
GE IC697ALG441
GE IC697ALG440
GE IC697ALG440
GE IC697ALG320
GE IC697ALG230
GE IC695PSD140
GE IC695PSD040
GE IC695PSA140
GE IC695PSA040
GE IC695PNC001
GE IC695PBM300
GE IC695MDL765
GE IC695MDL664
GE IC695LRE001
GE IC695HSC308
GE IC695HSC304
GE IC695GCG001
GE IC695ETM001
GE IC695EIS001
GE IC695EDS001
GE IC695ECM850
GE IC695CRU320-EN
GE IC695CRU320-CD
GE IC695CRU320CA-EL
GE IC695CRU320
GE IC695CRU320
GE IC695CRU320
GE IC695CRU320
GE IC695CPU315
GE IC695CPU315
GE IC695CPL410CA
GE IC695CPL410
GE IC695CPK400
GE IC695CPK330CA
GE IC695CPK330
GE IC695CPE400CA
GE IC695CPE400
GE IC695CPE330LT
GE IC695CPE330CA
GE IC695CPE330-ABAF
GE IC695CPE330
GE IC695CPE330
GE IC695CPE330
GE IC695CPE330
GE IC695CPE310LT
GE IC695CPE310CA
GE IC695CPE310
GE IC695CPE310
GE IC695CPE305LT
GE IC695CPE305CA

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts