Description
F6706 Germany HIMA
F6706 Germany HIMA
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com
In measurement and control, there are power supply grounding systems, analog signal grounding systems, and digital signal grounding systems. In order to eliminate mutual interference between different systems, the ground of each system should be separated. But ground and grounding are different concepts, and here ground refers to the common reference point of the system. And what people often say about grounding is to fix the “zero potential” by grounding the common point. Grounding is for safety and prevention of danger. In production sites, the grounding system is mostly grounded nearby. If there is more than one grounding point, a grounding circuit will be generated, and current flowing through the grounding circuit will also occur, which will cause coupling interference problems.
Figure 1 Schematic diagram of grounding at both ends of the shielded wire F6706 Germany HIMA
As shown in Figure 1, there will be a potential difference between ground point A and ground point B, and there will also be a current. This interference signal will be mixed with useful signals, which is the first type of interference signal. If the shielding layer of the signal line in Figure 1 is grounded at both ends of the signal source and secondary instrument, the induced current of the shielding layer will be coupled to the signal line through the distributed capacitance between the shielding layer and the signal line. This interference signal is mixed with the useful signal, which is the second type of interference signal. To eliminate the second type of interference, the first step is to avoid creating a ground circuit. Grounding one end of the shielding layer can achieve the goal, that is, the signal source and signal shielding wire are only grounded at one point to disconnect the ground circuit, as shown in Figure 2. Although the common point of the secondary instrument is connected to ground point B, it will not form a ground circuit. At the same time, floating measures are taken at the input end of the secondary instrument to the ground to isolate the signal line of the secondary instrument from the casing, which has a better effect. These methods can basically prevent the generation of ground current interference.
Figure 2 Schematic diagram of grounding at one end of the shielded wire
When grounding at one point, it is also important to choose a grounding point. For shielded wires, the grounding point should be close to the entry point of the shielded induction circuit, as shown in Figure 2. If point B is a high-level electric field and point A is a low-level electric field, to avoid interference from high-level electric fields on low-level electric fields, the grounding point should be as close as possible to the entry point of low-level A.
If the signal line is shielded, it should be grounded near the interference source. In short, the principle of grounding is to try to prevent the induced current on the shielding layer from flowing into the signal line to avoid introducing interference. If the grounding is connected to the input terminal of the secondary instrument, the induced current of the shielding layer may flow through the signal line to introduce interference. But if the grounding point is connected to point A, as the shielding layer and signal line are considered equipotential, no current flows through the signal line. F6706 Germany HIMA
For long-distance transmission of signal lines, due to the length limitation of a single wire, there may be wiring issues with extension wires. In this case, the continuity of shielding should be ensured, that is, the use of junction boxes should be avoided as much as possible. If a junction box is necessary, the shielding should be as close as possible to the signal terminals, and the exposed signal line length should not exceed 20mm. At this time, the shielding layer should also be connected or welded using terminals.
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit
Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts