Description
P0931RR PDF
The products and services provided by P0931RR FOXBORO include but are not limited to:
P0931RRinstructions P0931RRTechnical Manual
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com
Guoxin Yangdian ABB excitation regulator technology upgrade
1 Overview
The 2×630Mw coal-fired units (units #3 and #4) of Jiangsu Guoxin Yangzhou Power Generation Co., Ltd. were put into commercial operation in September 2006 and January 2007 respectively. The generator excitation system is a complete set of excitation system equipment imported from Switzerland provided by Shanghai ABB Engineering Co., Ltd. The supporting excitation system is ABBUnitrol5000. For more than 10 years of operation, jumper Hall elements have been disturbed and tripped, and ARCnet communication faults have tripped. and other problems, and as the use time increases, the failure rate increases significantly, and the stability of the excitation system gradually decreases. According to the needs of unit capacity increase, efficiency improvement and upgrading, the company has simultaneously upgraded the excitation system, upgraded the original Unitrol5000 to the latest Unitrol6800 system, and also adjusted the original components such as resistance-capacitance absorbers and jumpers. Make sure the parameters match.
2 Advantages of the modified excitation system
2.1 The reliability of the three-channel input power supply redundancy mode in the control part is improved
The power supply of the control part adopts three input power supplies with AC or DC redundancy mode, thus improving the reliability of the system. Each control module is equipped with two independent power supplies for power supply, which significantly improves the redundancy of the power supply. In this way, the power supply of the control module can be disconnected separately to facilitate online replacement of faulty components. Secondly, since the boards are installed independently and each board is powered by dual power supplies, the power supply has an independent switch, making online maintenance work safer.
2.2 Fiber optic redundant internal communications
Unitrol6800 uses optical fiber redundancy for internal communication, which avoids the problem of downtime caused by ARCnet serial communication in the Unitrol5000 system. The controller can independently transmit the trigger pulse of the thyristor to the rectifier bridge. In conjunction with optical fiber transmission, the trigger pulse can be generated in each rectifier bridge, making the internal communication more resistant to interference.
2.3 Eliminate the security risks brought by the public PSl board in the original system to the system
Unitrol6800 uses a rectifier cabinet to separately collect the synchronization voltage, excitation voltage and excitation current, which reduces the safety hazards caused by the public PsI board. In the rectifier bridge of Unitrol6800, the AC side phase sequence detection function is added. The fan power supply uses the independent power distribution method of each rectifier cabinet. The fan power supply loop control system of all rectifier cabinets is inside the rectifier cabinet, ensuring that each rectifier cabinet is It can independently control the fan in the cabinet, thereby solving the problem of power loss in the fan circuit of Unitrol5000 due to relay failure and avoiding non-stop accidents.
In the rectifier bridge of the Unitrol5000 system, a Hall element is installed on the rectifier side to measure the excitation current of the rectifier bridge. The current sharing of the excitation current by the system must be carried out through a current sharing test. However, the characteristics of the Hall element itself prevent it from being based on the load. changes in dynamic current sharing. To this end, in the Unitrol6800 system, a CT is installed on the AC incoming line side of the rectifier cabinet to sample and calculate the excitation current. The linearity of the CT is very high, which ensures that the excitation system can perform dynamic current sharing according to the load changes of the working conditions, allowing Each rectifier cabinet of the system can be more balanced.
In the rotor overvoltage protection of the Unitrol6800 system, a current relay is used to detect the current. Since the anti-interference ability of the current relay is stronger than the Hall element of the Unitrol5000, it can avoid false alarms of the rotor overvoltage in the excitation system caused by external interference and avoid power generation. The occurrence of unit non-stop accidents.
3 Renovation Plan
The steam turbine generator unit has been modified to increase capacity and improve efficiency. The rated output of the steam turbine unit has been increased from 630Mw to 650Mw, the self-set rated current of the generator has been increased from 17495A to 19245A, and the rated voltage of the excitation rotor has also been increased from 400.1V to 428V. The excitation current increases from 4387.4A to 4697A. In this transformation, the cabinet structure of the excitation system remains unchanged. The system upgrade is achieved by upgrading boards, updating equipment and upgrading the control system. During the transformation process, it is necessary to ensure that the generator capacity is increased, and the excitation system needs to provide more excitation current and voltage to ensure the stable operation of the unit by increasing the deexcitation capacity.
3.1 Adjustment of demagnetization and AC side voltage absorption module
Since the generator is upgraded from 630Mw to 650Mw, the demagnetization and AC side overvoltage absorption modules need to be adjusted. For the adjustment of the capacity of the excitation de-excitation resistor, the capacity calculation of the de-excitation resistor needs to be calculated based on the most serious de-excitation state of the generator. The demagnetizing resistor is a siC nonlinear resistor. The number of resistors is changed from 5 to 6. The capacity of the demagnetizing resistor is 6MJ, which meets the needs of the excitation system for demagnetizing. In the modification of the demagnetization circuit jumper, the voltage resistance level of the thyristor was improved by replacing the jumper and BoD board. Regarding the transformation of the overvoltage absorption module on the AC side of the rectifier bridge, according to the design of the rectifier bridge of the ABB excitation system, the overvoltage absorption modules on the AC side of the rectifier bridge were changed to five groups in parallel.
Display operation panel 3HAC033548-008
Display operation panel 3HAC033548-006
Display operation panel 3HAC033434-001
Display operation panel 3HAC033389-001
Display operation panel 3HAC033363-001
Display operation panel 3HAC033234-002
Display operation panel 3HAC033203-001
Display operation panel 3HAC033203-001
Display operation panel 3HAC033163-001
Display operation panel 3HAC033163-001
Display operation panel 3HAC032972-002
Display operation panel 3HAC032934-001
Display operation panel 3HAC032723-001
Display operation panel 3HAC032718-001
Display operation panel 3HAC032586-001
Display operation panel 3HAC032560-005
Display operation panel 3HAC032508-001
Display operation panel 3HAC032203-005
Display operation panel 3HAC032203-004
Display operation panel 3HAC032203-003
Display operation panel 3HAC032203-002
Display operation panel 3HAC032124-003
Display operation panel 3HAC031977-001/04
Display operation panel 3HAC031958-002
Display operation panel 3HAC031840-004
Display operation panel 3HAC031825-001
Display operation panel 3HAC031782-001
Display operation panel 3HAC031683-004
Display operation panel 3HAC031683-001
Display operation panel 3HAC031683-001
Display operation panel 3HAC031670-001
Display operation panel 3HAC031587-001
Display operation panel 3HAC031580-004
Display operation panel 3HAC031580-001
Display operation panel 3HAC031470-001
Display operation panel 3HAC031153-002
Display operation panel 3HAC031151-002
Display operation panel 3HAC031074-004
Display operation panel 3HAC030923-001/08
Display operation panel 3HAC030923-001
Display operation panel 3HAC030923-001
Display operation panel 3HAC030868-001
Display operation panel 3HAC030825-001
Display operation panel 3HAC030800-001
Display operation panel 3HAC030793-001
Display operation panel 3HAC030789-001
Display operation panel 3HAC030770-001
Display operation panel 3HAC030647-002
Display operation panel 3HAC030430-001
Display operation panel 3HAC030414-001
Display operation panel 3HAC030301-001
Display operation panel 3HAC030281-003
Display operation panel 3HAC030205-002
Display operation panel 3HAC030180-001
Display operation panel 3HAC030124-001
Display operation panel 3HAC030064-001
Display operation panel 3HAC030059-001
Display operation panel 3HAC030057-001
Display operation panel 3HAC029840-003
Display operation panel 3HAC029818-001/11
Display operation panel 3HAC029818-001
Display operation panel 3HAC029818-001
Display operation panel 3HAC029721-001
Display operation panel 3HAC029720-001
Display operation panel 3HAC029705-001
Display operation panel 3HAC029699-003
Display operation panel 3HAC029565-003
Display operation panel 3HAC029539-001
Display operation panel 3HAC029517-001
Display operation panel 3HAC029501-003
Display operation panel 3HAC029392-004
Display operation panel 3HAC029287-001
Display operation panel 3HAC029286-001
Display operation panel 3HAC029285-001
Display operation panel 3HAC029157-001/07
Display operation panel 3HAC029157-001
Display operation panel 3HAC029147-001
Display operation panel 3HAC029146-001
Display operation panel 3HAC029145-001
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit
Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts