Sale!

PCI-6221 Data acquisition card

¥666.00

PCI-6221 Data acquisition card
Brand: National Instruments
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

PCI-6221 Data acquisition card
PCI-6221 Data acquisition card
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com

I cannot see my third-party USB instrument in Measurement&Automation Explorer (MAX), but it exists as a USB instrument in Windows Device Manager. Why do we see this phenomenon and how can we solve it so that we can communicate with the instrument?
My USB-6343 performs normally in Windows Device Manager, but in MAX, there is a yellow triangle and a message is displayed: There was a problem updating the settings for this device. The operation timed out.
I cannot see my 3rd Party USB devices in MAX, but I can communicate with them through the command line, so I know they are connected. What do I need to do to see my device in MAX?
Solution
If the device is displayed in the Windows Device Manager, it indicates that the Windows machine can recognize the USB device and has associated a specific driver to communicate with the device. One possible reason why the instrument did not display in MAX is that Windows did not associate the correct driver with the device.
Check if the NI-VISA driver is installed on the computer. If doing so, please check the compatibility between NI-VISA and LabVIEW, as well as the compatibility between NI-VISA and the operating system. If not, please visit the NI-VISA download page and download and install the appropriate driver. Please ensure to restart the computer after installation.
Try resetting the MAX database, as described in the article on how to repair or reset the NI MAX database file.
If you are using a third-party VISA device on the same computer, you may need to set NI-VISA as the primary VISA implementation, as described in the NI VISA article after installing third-party VISA software.
Uninstall and reinstall the NI-VISA driver. When reinstalling, if possible, disable all firewalls and antivirus software.
If NI-VISA is installed, please try re associating the USB device to use the NI-VISA driver:
Go to Windows Device Manager and search for USB devices according to the following image.
Use NI”s counting/timer or M-series board to complete resettable pulse counting PCI-6221 Data acquisition card
Main software:
Main software version: 1.0
Main software revision version: N/A
Secondary software: LabVIEW Development Systems>>LabVIEW Base Package
Hardware: Counter/Timers (TIO)>>Devices>>PCI-6601
Question: I want to use NI”s counting/timer or M-series board to perform edge counting on my input signal and reset the count with another pulse signal.
Answer: If an external trigger source is used, such requirements can be completed using any of NI”s M-series cards with a counter or counting/timer. The counting/counter board is particularly suitable for generating counting reset signals, as other counters on the board can be used to generate a pulse signal of a known frequency.
There are two ways to use the counter input. The first method is a two channel pulse encoding method with Z index. This method uses two input signals, channel A and channel B, to count, while the Z-channel signal is used to reset the count. This method uses the rising edge of channel A to increase the count, while the rising edge of channel B to decrease the count. Therefore, the two pulse encoding method is also called an add/subtract counter.
Set the signal values in channels A and B to determine when the Z-channel signal triggers a count reset. This allows you to perform an accurate count reset without causing loss of counts for channels A and B. Count reset can be completed within one clock cycle of the maximum time base.
For a specific example, if we only need to increase the count, we can ground channel B. The relevant connection relationships for this setting are as follows:
Ctr Source: Incremental count signal (channel A)
Ctr AUX: Decrement count signal (channel B) – connected to ground
Ctr Gate: Reset signal (Z-path index)
The following figure describes the Counting process of resetting the count when the channel A and channel B signals are both low.
Regarding the Z-path index, both page 39 of the 6601/6602 User Manual and page 120 of the M Series User Manual need to be introduced.
The following attachment is a simple VI example using Z-path indexing.
The second measurement method is buffer period measurement. The relevant content is detailed on the NI Developer Zone website.

 

原装DS200TCCAG1AHB供应
原装DS200ACNAG1ACC供应
1394-SJT05-C-RL 罗克韦尔伺服控制器
1394-SJT10-C-RL 罗克韦尔A-B GMC系统模块 1394C-SJT22-A
1394-SJT22-A A-B GMC 标准系统模块 数字伺服驱动器
1394-SJT22-T-RL/A诚信服务
1398-DDM-075 A-B 罗克韦尔 超200系列 数字伺服驱动器
140AC013000 模拟量输出模块 Modicon
140ACI03000  SCHNEIDER 模拟输出模块
140ARI03010 输入模块
140ATI03000 莫迪康 模拟输入模块
RF533 3BSE014227R1 ABB 机架
SA811F 3BDH000013R1 ABB 输入输出模块
SA9923a-E HIEE450964R0001 ABB 处理器 模块
SC560 3BSE008105R1 ABB CPU模块 处理器模块
140CFI00800  140系列  数字输出块  模拟量输出块
140CFJ00400 140系列  数字输出块  模拟量输出块
“140CFJ00400 模拟量输出模块施耐德 SCHNEIDER”
“140CFK00400 模拟量输出模块施耐德 SCHNEIDER”
140CPS11420C 140系列 电源,115/230 VAC,11Amp,
140CPS41400C  140系列 电源,115/230 VAC,11Amp,
140CPS42400C  140系列 电源,115/230 VAC,11Amp,
140CPS51100C 140系列 电源,115/230 VAC,11Amp,
SCYC51010 58052515G ABB CPU模块 处理器模块
140CPU11302
UCD240A101 3BHE022287R0101 ABB 通讯板
UFC760BE41 3BHE004573R0041 ABB 处理器模块
UFC911B110 3BHE037864R0110 ABB 处理器模块
XDD501A101 3BHE036342R0101 ABB PLC模块
控制器 模块 CSA464AE HIEE400106R0001 ABB
原装336A4940CSP20 IS220PPRFH1A
140CPU11302 140系列  通讯总线模块  处理器电源模块
140CPU31110 系统配件 电源模块   SCHNEIDER
140CPU43412A MODICON 可编程逻辑控制器
140CPU65150 Unity 处理器 无算术协控制器 Modicon Quant
140CPU65260 140系列 SCHNEIDER 通讯总线模块 处理器电源模块
140CPU65260 CPU模块 PLC系统备件
140CPU65260 UNITY 处理器 MODICON可编程逻辑控制器
140CPU65860 Modicon Quantum Unity 处理器
140CPU65860 SCHNEIDER  处理模块  系统配件
140CPU65860C 140系列 CPU 486处理器  66MHz  2M SRAM
140CPU67060C 140系列 CPU 486处理器  66MHz  2M SRAM
140CPU67160 SCHNNEIDER 多模式处理器 module
140CPU67160C SCHNEIDER 热备用处理器 140CPU65260
140CPU67160C SCHNEIDER 通讯总线模块 以太网IO主适配器
140CPU67160C统一热备处理器
140CPU67160施耐德CPU模块 SCHLEICHER 140CPU67160C
140CPU67260热备处理器 多模光纤同步接口 工控售后服务
“140CRA21110 适配器 电源 施耐德 SCHNEIDER”
“140CRA21210 施耐德 SCHNEIDER 适配器 电源”
140CRA31200 140系列  通讯总线模块  以太网IO主适配器
140CRA31200 以太网适配器
140CRA93200
140CRA93200 双通道模块
140CRP31200通信模块 自动化备件正品质保实货
140CRP93100 140系列  通讯总线模块  以太网IO主适配器
140DAO84000施耐德 输出模块  SCHNEIDER莫迪康
140DAO84210施耐德 输出模块  SCHNEIDER莫迪康
140DDI35300  SCHNEIDER 施耐德量子化系列 离散输入模块
140DDI35310施耐德  SCHNEIDER输入模块   莫迪康
140DDI36400施耐德  SCHNEIDER输入模块   莫迪康
PCI-5421 NI发生器设备 两个双向通道100 MS/s
140DDI84100施耐德  SCHNEIDER输入模块   莫迪康
140DDO35300施耐德 输出模块 SCHNEIDER 系统配件
140ESI06210 施耐德 通讯模块SCHNEIDER
140NOM21200 适配器  施耐德 SCHNEIDER 库存备件
用于 SLC 的 MVI46-AFC PROSOFT 气体和液体流量计算机
应用材料 AMAT 接口板 0190-18138 ABX-X272 PS PCB 原装进口

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts