Sale!

PXI-2569 Data acquisition card

¥666.00

PXI-2569 Data acquisition card
Brand: National Instruments
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

PXI-2569 Data acquisition card
PXI-2569 Data acquisition card
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com

I cannot see my third-party USB instrument in Measurement&Automation Explorer (MAX), but it exists as a USB instrument in Windows Device Manager. Why do we see this phenomenon and how can we solve it so that we can communicate with the instrument?
My USB-6343 performs normally in Windows Device Manager, but in MAX, there is a yellow triangle and a message is displayed: There was a problem updating the settings for this device. The operation timed out.
I cannot see my 3rd Party USB devices in MAX, but I can communicate with them through the command line, so I know they are connected. What do I need to do to see my device in MAX?
Solution
If the device is displayed in the Windows Device Manager, it indicates that the Windows machine can recognize the USB device and has associated a specific driver to communicate with the device. One possible reason why the instrument did not display in MAX is that Windows did not associate the correct driver with the device.
Check if the NI-VISA driver is installed on the computer. If doing so, please check the compatibility between NI-VISA and LabVIEW, as well as the compatibility between NI-VISA and the operating system. If not, please visit the NI-VISA download page and download and install the appropriate driver. Please ensure to restart the computer after installation.
Try resetting the MAX database, as described in the article on how to repair or reset the NI MAX database file.
If you are using a third-party VISA device on the same computer, you may need to set NI-VISA as the primary VISA implementation, as described in the NI VISA article after installing third-party VISA software.
Uninstall and reinstall the NI-VISA driver. When reinstalling, if possible, disable all firewalls and antivirus software.
If NI-VISA is installed, please try re associating the USB device to use the NI-VISA driver:
Go to Windows Device Manager and search for USB devices according to the following image.
Use NI”s counting/timer or M-series board to complete resettable pulse counting PXI-2569 Data acquisition card
Main software:
Main software version: 1.0
Main software revision version: N/A
Secondary software: LabVIEW Development Systems>>LabVIEW Base Package
Hardware: Counter/Timers (TIO)>>Devices>>PCI-6601
Question: I want to use NI”s counting/timer or M-series board to perform edge counting on my input signal and reset the count with another pulse signal.
Answer: If an external trigger source is used, such requirements can be completed using any of NI”s M-series cards with a counter or counting/timer. The counting/counter board is particularly suitable for generating counting reset signals, as other counters on the board can be used to generate a pulse signal of a known frequency.
There are two ways to use the counter input. The first method is a two channel pulse encoding method with Z index. This method uses two input signals, channel A and channel B, to count, while the Z-channel signal is used to reset the count. This method uses the rising edge of channel A to increase the count, while the rising edge of channel B to decrease the count. Therefore, the two pulse encoding method is also called an add/subtract counter.
Set the signal values in channels A and B to determine when the Z-channel signal triggers a count reset. This allows you to perform an accurate count reset without causing loss of counts for channels A and B. Count reset can be completed within one clock cycle of the maximum time base.
For a specific example, if we only need to increase the count, we can ground channel B. The relevant connection relationships for this setting are as follows:
Ctr Source: Incremental count signal (channel A)
Ctr AUX: Decrement count signal (channel B) – connected to ground
Ctr Gate: Reset signal (Z-path index)
The following figure describes the Counting process of resetting the count when the channel A and channel B signals are both low.
Regarding the Z-path index, both page 39 of the 6601/6602 User Manual and page 120 of the M Series User Manual need to be introduced.
The following attachment is a simple VI example using Z-path indexing.
The second measurement method is buffer period measurement. The relevant content is detailed on the NI Developer Zone website.

 

PXI-4461
PXI-5600
PXI-5152
PXI-6071E
PXI-6052E
PXI-6070E

PCI-6052E
PXI-4130
AT-FBUS
PCI-7833R
PXI-6070E
PCI-6289
PXIe-6544
SWB-2816A
PXI-4071
NI-1774
PXIe-5605
SWB-2816B
PXI-8108
PCI-8512
PXI-1045
PXI-8430
PXI-8106
PXI-8331
PXI-8106
PXIe-5605
PXIE-6674
PXI-7831R
PXI-8102
PXI-8109
PXI-5124
PXIe-4141
NI-9036
PXIe-4480
PXIe-5630
PXI-1044
PXI-8106

PXI-5421
PXI-5122
PXI-2593
PXI-2591
PXI-6071E
PXI-4461
PXI-8310
PXI-5153
PXI-5651
PXIe-1085
PXIe-5665
PXI-5142
PXI-5421
PXI-5124
PXI-5441
PXI-8517
sbRIO-9642
PXIe-4480
PXI-1044
PXI-8106
PXI-4110
PXI-6602
PXI-6250
PXIe-5645R

PCI-6120
PXIe-6363
PXI-5153
PCI-4451
sbRIO-9626
PXI-5610
PCI-6031E
cRIO-9081
PXI-5154
NI5791
PXI-1062Q
PXI-6120
PXI-1042Q
PXI-4472
PXIe-4163
PXI-2532B
USB-6356
PXI-7831R
PXI-4472B
PXIe-5646R
PXI-7853R
PXIe-5644R
PXI-1000B
PXIe-7976R
PXIe-5646R
PXIe-8135
NI4472
SCXI-1129
PXI-5154
PXI-6289
PXIe-2569
PXI-1042
PXI-8196
PXI-7350

PXI-6040E
PXIe-5673E
PXI-5600
PXI-7853R
PXIe-5645R
PXIe-4480
PCI-5153
PXIe-6545

PXI-6733
PXI-7831R
PXI-6552
cRIO-9068
PXI-5651
PXI-5651
PXI-6733
PXI-5421
CFP-2020
cfp-Do-401
cfp-cb-1
cfp-ao-210
cfp-ai-100
cRIO-9081
PXI-4495
PXIe-5646R
PXIe-8370
PCIE-8371
cDAQ-9185
PXIe-1491
PCIe-6351
PXI-4472
PXIe-5641R
PXI-7954R
PCI-8517

cRIO-9082
PXIe-5605

PXI-4224
PXIe-6672
PXIe-1075
PXIE-8840

SMA-2164
PXI-2529
NI1744
PXI-7953R
PXI-5671
PXI-5650
PXI-5124
154748A-01

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts