Sale!

UPC325AE01 3BHB000644R0001 DCS system

¥666.00

UPC325AE01 3BHB000644R0001 DCS system
Brand: General Electric
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

UPC325AE01 3BHB000644R0001 DCS system
UPC325AE01 3BHB000644R0001 DCS system
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com

Detailed explanation of scaling causes and treatment methods of steam turbine condenser
Condenser equipment is an important part of steam turbine unit. Its working performance directly affects the safety, reliability, stability and economy of the whole steam turbine unit. The vacuum degree of condenser is an important indicator of steam turbine operation, and also a major assessment indicator reflecting the comprehensive performance of condenser. The vacuum level of the condenser has a direct impact on the economy of the steam turbine generator unit, and in serious cases, directly affects the generating load of the unit. Therefore, keep the condenser in good operating condition and ensure the most favorable vacuum of the condenser; It is an important part of energy saving in power plants.
1、 Equipment overviewUPC325AE01 3BHB000644R0001 DCS system
Two sets of 12MW medium-temperature and medium-pressure condensing steam turbine generator units in a certain plant have the following condenser parameters:
Model: N-1000-7 Type: split two-pass surface type
Cooling area 1000m2 Cooling water volume 3000/h
Maximum allowable water pressure in the water chamber: 0.34MPa Water resistance: 265kPa
Net weight: 22.2t Operating weight: 35.8t
Specification of cooling stainless steel pipe: 20 * 0.7 * 4562mm
Quantity: 3540 pieces Material: 304
2、 Operation status
The vacuum of steam turbine is gradually low during operation, the vacuum value is gradually reduced from – 88 kpa to – 77 kpa, the end difference is increased from 11 ℃ to 34 ℃, the circulating water supply temperature is less than 30 ℃, the circulating water volume is more than 6000 m3/h, the circulating ratio is more than 60, and the circulating water temperature and flow fully meet the operation requirements. The long-term low vacuum operation will affect the efficiency of the unit. If the vacuum continues to decrease, it will threaten the safe operation of the unit. In order to ensure that the unit operates within the safe range, the load of the generator is reduced, with the maximum load of 80% of the rated load, which seriously affects the efficiency of the unit.
3、 Existing problems and cause analysis
The main characteristics of condenser vacuum drop are as follows: 1. The exhaust steam temperature rises; 2. Condensate supercooling increases; 3. The indication of vacuum gauge decreases; 4. The condenser end difference increases; 5. The unit vibrates; 6. Under the condition that the opening of the regulating valve remains unchanged, the load of the steam turbine decreases.
Cause analysis of condenser vacuum drop: the causes of condenser vacuum drop of steam turbine can be roughly divided into external causes and internal causes: external causes mainly include interruption or insufficiency of circulating water volume, rise of circulating water temperature, interruption of rear shaft seal steam supply, failure of air extractor, etc; Internal causes mainly include full water (or rising water level) of condenser, scaling of condenser, deterioration of heat transfer, tightness of condenser vacuum system, air inflow caused by steam side leakage, etc. The most common cause is the scaling in the condenser tube, which is mainly biological slime and carbonate hard scale, and some are phosphate and silicate hard scale. Condenser scaling seriously affects the condensation effect, and affects the end difference, vacuum degree and power generation. Scaling shortens the service life and normal output of condenser equipment. If the scale of condenser tube reaches 0.3 mm, the efficiency of steam turbine will be affected; More than 0.5mm can affect the output of steam turbine, and corrosion leakage is mainly caused by scaling of circulating water. Scaling leads to a significant reduction in the working efficiency of the condenser and affects the operation economy and safety of the unit.
From the analysis of operation, it is judged that it is caused by condenser scaling; Take advantage of the turbine maintenance opportunity, open the condenser manhole, check the condenser cooling water pipe, check that the scaling thickness of the upper condenser cooling pipe is greater than 1mm, and the lower part is gradually reduced to 0.5mm (the reason is that the upper condensed steam temperature is high, and the lower condensed steam temperature has decreased), and the water outlet side is significantly more serious than the inlet side.
Causes of scaling of steam turbine:
1. The design rated steam exhaust load of the power generation condenser is 50/h, the current steam exhaust load is 58-64 t/h, and the overload operation is nearly 20%.
2. The low-pressure heater is out of operation according to the requirements of the boiler, and~5t/h of steam that should have entered the low-pressure heater enters the condenser, causing the condenser to overload.
3. Since the boiler requires the main steam pressure not to be higher than 3.7MPa, the steam pressure sent to the steam turbine is only 3.2MPa, which is 3.42MPa lower than the design rated pressure. At the rated load, 2tVh more steam is consumed, and the condenser load is increased by 2t/h.
4. In order to complete the power generation, the unit load is controlled at 12.5MW, which consumes 2tVh more steam than the rated 12MW, and the condenser load is increased by 2t/h.
5. The increased steam intake of the above items will further affect the vacuum reduction of the condenser. Under the requirement of ensuring that the unit is loaded, the steam intake will also increase relatively, forming a reverse cycle, which will also cause the end difference to rise.
6. The supervision of circulating water quality is not in place, and the turbidity and concentration ratio increase frequently. The working environment of the cooling tower is poor, the water turbidity is high, the system evaporation is large, the concentration is fast, and the sewage discharge is small. Insufficient dosage of bactericide, scale inhibitor and dispersant and high hardness of source water will cause scaling of condenser cooling pipe.
4、 Solution
Condenser scaling cleaning methods are divided into physical cleaning and chemical cleaning. Physical cleaning usually adopts four methods:
1. Manual poking and washing. It is a manual reciprocating stabbing and brushing of the condenser tube with a stabbing bar. In order to remove the scale in the pipe, because it is only manual poking and washing, only soft scale and a small amount of hard scale can be removed, which is not thorough and labor intensive, and cannot achieve satisfactory results. Moreover, the mechanical damage to the cooling water pipe is relatively serious, and the old scale that has not been removed is used as crystal nucleus, which accelerates the scaling speed; 2. Rubber ball cleaning. It adopts the way of parallel connection between rubber ball system and circulating water system. It needs to be put into use frequently, but only soft scale can be removed, which can not play a role in the formation of hard scale.
3. High pressure water jet cleaning. This kind of cleaning effect is good. It uses high pressure water spray to remove most of the dirt in the pipe through the pipeline of the equipment to be cleaned. However, due to high labor intensity, low descaling rate, long cleaning time, high pressure causes serious mechanical damage to condenser tubes.
4. Chemical cleaning of condenser scaling. The main purpose of chemical cleaning is to remove calcium carbonate scale on the surface of condenser. Chemical cleaning of condenser has the following advantages: First, the effect of removing hard scale is good, and the rate of chemical cleaning is high. Chemical cleaning can achieve the goal of completely removing dirt, and its scale removal uniformity is consistent, and the effect is good. 2、 The cleaning time is short. Because the main components of the fouling on the condenser copper pipe are carbonate and sludge, the chemical cleaning method is applied, which has short cleaning time and simple process.
After comprehensive evaluation, it is decided to adopt chemical cleaning method. The specific scheme of chemical cleaning is:
The main process of circulating water system cleaning: descaling treatment → water replacement → hanging solid agent
Chemical cleaning agent dosage:

 

GE DS200TCQAF1AFC 现场控制 工控卡件模块
GE DS200TCQAF1AEE VMIC模块 雄霸供应
GE DS200TCPSG1APE 涡轮控制系统模块 自动化机械备件
GE DS200TCPSG1APE 燃机卡 涡轮控制模块 进口电气产品
GE DS200TCPSG1ALE Multilin机器人系统模块
GE DS200TCPAF2AAB ARCNET连接板 进口工控备件
GE DS200TCEBG1ACE Boards 局域网通信卡 进口电气产品
GE DS200TCEBG1A LAN通信卡 机器人系统模块
GE DS200TCEAP1BBC 本地网络的驱动器通信 工控卡件模块
GE DS200TCEAG2BTF LAN局域网通信卡 进口工控备件
GE DS200TCEAG2B 网络通讯控制板 库存货品
GE DS200TCEAG1BSF 显示板 进口电气产品
GE DS200TCEAF1BDE 电流监控 库存货品
GE DS200TCEAF1ACM GE继电系列 进口电气产品
GE DS200TCEAF1ACK Multilin 通用继电器 CPU模块
GE模块DS200RTBAG1A原装供应
GE模块IC697CPX928-F库存
GE DS200TCEAF1ACH LCI转换接口控制器 进口工控备件
GE DS200TCDAG2B 发电机管理继电器 CPU模块
GE DS200TCDAF1BCN Mark Vle 控制器模块 全系列
GE DS200TCCBP2BAB GTC控制方案 全系列
GE DS200TCC-BG8BED 336A系列模块 进口电气产品
DS200SLCCG2AGE通用电气模块
GE DS200TCCBG6B 以太网模块 进口电气产品 DS200全系列
GE DS200TCCBG6B 电流互感器 工控备件模块库存
GE DS200TCCBG3ANE CPU 处理器模块 库存有货
GE DS200TCCBG3A 通用控制模块 库存货品 控制器显示面板
GE DS200TCCBG2A PPG处理器模块 进口电气产品
GE DS200TCCBF1BDC 电动机保护器 全系列
GE DS200TCC-AG1AHB ARCNET连接板 自动化机械备件
GE DS200TCCAF1ADA 本地网络的驱动器通信 CPU模块
GE DS200TCCAF1ACE 用于驱动器和励磁器 机器人系统模块
GE DS200TCCAF1ACC 美国通用模块 工控备件模块库存
DS200TCQAG1BGE放心选择
GE DS200TBQFG1A 用于控制燃气或蒸汽涡轮机组 库存货品
GE DS200TBQDG1AEE 用于励磁器和驱动器 进口电气产品
GE DS200TBCAG1A Multilin CPU模块 库存有货
GE DS200SVMAG1A 发电机管理继电器 库存货品
GE DS200SVIAG1A Ur控制器模块 全系列
GE DS200SVAAG1ACC- Multilin RS485 CPU卡件 停产备件
GE DS200STCAG1A Multilin 信号转换模块 机器人系统模块
GE DS200SSBCG1A 电源断路器 库存有货
GE DS200SSBAG1A 继电器模块 进口电气产品
GE DS200SLCCG3ACC/DS215DENQG3AZZ01A 化工行业 停产备件
GE DS200SLCC-G3A Multilin Ur控制器模块 自动化机械备件
GE DS200SLCCG1AGH PPG处理器模块 雄霸供应
GE DS200SLCC-G1AEF PLC处理器板卡 CPU模块
GE DS200SHVMG1AGE 驱动器数据管理器 进口工控备件
GE DS200SHCBG1A Mark V板系列 雄霸供应
GE DS200SHCAG1B LAN局域网通信卡 全系列
GE DS200SDCIG2A 电路板 机器人系统模块
GE DS200SDCC-G4R Multilin 通用继电器 工控卡件模块
GE DS200SDCCG4AFD Multilin 校准模块 雄霸供应
GE DS200SDCCG4A UR模块 全系列
GE DS200SDCC-G3A CT/VT单元 停产备件

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts